BLDG1403-0166-Energy CalculationsFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Street: City, State, Zip: Owner: Design Location: LH -A -ML 120 9600 TOWN PARC CIRCLE NORTH PARKLAND, FL, A INT. MODEL LOT 2 BLOCK 5 @ TOWN PARC FL, Fort Lauderdale 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) New (From Plans) Multi -family 1 3 No 1887 0 7. Windows(138.0 sqft.) Description Area a. U -Factor: Sgl, U=1.08 114.00 ft2 SHGC: SHGC=0.49 b. U -Factor: Sgl, U=1.08 24.00 ft2 SHGC: SHGC=0.38 c. U -Factor: N/A SHGC: d. U -Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.717 ft. Area Weighted Average SHGC: 0.471 ft2 8. Floor Types (1057.1 sqft.) a. Slab -Ort -Grade Edge Insulation b. Raised Floor c. N/A Glass/Floor Area: 0.073 Insulation Area R=0.0 791.10 ft2 R=11.0 266.00 ft2 R= ft2 Builder Name: LENNAR HOMES Permit Office: Permit Number: Jurisdiction: 163100 9. Wall Types (2310.8 sqft.) Insulation a. Concrete Block - Ext Insul, Common R=4.1 b. Concrete Block - Ext Insul, Exterior R=4.1 c. Frame - Wood, Adjacent R=11.0 d. N/A R= 10. Ceiling Types (1126.0 sqft.) Insulation a. Under Attic (Vented) R=30.0 b. N/A R= c. N/A R= 11. Ducts a. Sup: Attic, Ret: Attic, AH: 2ND FLR HALL 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits Total Proposed Modified Loads: 35.43 Total Standard Reference Loads: 46.37 I hereby certify that the plans and specifications covered by this calculation are in com an a with the Florida Energy Code. PREPARED BY: DATE: I hereby certify thatthis building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. Area 1386.00 ft2 708.75 ft2 216.00 ft2 ft2 Area 1126.00 ft2 ft2 ft2 R ft2 6 200 kBtu/hr Efficiency 27.6 SEER:16.00 kBtu/hr Efficiency 23.0 COP:1.00 Cap: 40 gallons EF: 0.920 Pstat PASS BUILDING OFFICIAL:`J t T , (4 -Alyce, 0 DATE: r -- 2 - i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 1/13/2014 10:02 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: LH -A -ML 120 User A INT. MODEL LOT 2 BLOCK 1 LENNAR HOMES 163100 Multi -family New (From Plans) PROJECT Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: Cross Ventilation: Whole House Fan: Design Location TMY Site FL, Fort Lauderdale FL_FORT_LAUDERDALE Number 1 Number 1 2 3 4 5 6 7 8 9 10 11 Name Area Entire House 1887 Name GREAT ROOM KITCHEN LIVING ROOM STAIRS POWDER MASTER BED MASTER BATH WIC MASTER 2ND FLR HALL BED SML CLOSET BED W LRG CLOS IECC Zone 1 Volume 17313 3 Address Type: Street Address 1887 Lot # 2 Block/SubDivision: No PlatBook: 180 Street: No County: No City, State, Zip: CLIMATE 9600 TOWN PARC CIR broward PARKLAND, FL , Design Temp Int Design Temp Heating Design Daily Temp 97.5 % 2.5 % Winter Summer Degree Days Moisture Range 43 91 BLOCKS SPACES Area Volume Kitchen Occupants 288 2592 No 0 143 1287 No 0 304 2736 No 0 30 600 No 0 26 236 No 0 285 2565 No 2 165 1485 No 0 88 792 No 0 224 2016 No 0 180 1620 No 1 154 1386 No 1 # Floor Type 1 Slab -On -Grade Edge Insulatio 2 Slab -On -Grade Edge Insulatio 3 Slab -On -Grade Edge Insulatio 4 Slab -On -Grade Edge Insulatio 5 Slab -On -Grade Edge Insulatio 6 Raised Floor 1/13/2014 10:02 AM FLOORS 70 75 321.5 60 Low Bedrooms Infil ID Finished Cooled Heated 3 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes Space Perimeter Perimeter R -Value Area GREAT ROOM 14 ft 0 287.8 ft2 KITCHEN 10 ft LIVING ROOM 18 ft STAIRS 10 ft POWDER 3.5 ft 2ND FLR HALL 0 0 0 0 143 ft2 304 ft2 30 ft2 26.3 ft2 59 ft2 Joist R -Value 11 Tile Wood Carpet 0.5 0 0.5 0.5 0 0.5 0.5 0 0.5 0.5 0 0.5 0.5 0 0.5 0.5 0 0.5 EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 # Floor Type 7 Raised Floor 8 Raised Floor # Type 1 Gable or Shed # Type 1 Full attic V # Ceiling Type 1 Under Attic (Vented) 2 Under Attic (Vented) 3 Under Attic (Vented) 4 Under Attic (Vented) 5 Under Attic (Vented) 6 Under Attic (Vented) 7 Under Attic (Vented) Adjacent To Wall Typo 1 W=>E Exterior 2 W=>E Exterior 3 E=>W Exterior 4 W=>E Exterior 5 W=>E Exterior 6 E=>W Exterior 7 E=>W Exterior 8 N=>S Neighbor 9 S=>N Neighbor 10 S=>N Garage Ornt 1 E=>W 2 S=>N 1/13/2014 10:02 AM FLOORS Space Perimeter Perimeter R -Value Area BED SML CLOSE ____ 101 ft2 BED W LRG CLO Materials Barrel tile Concrete Block - Concrete Block - Concrete Block - Concrete Block - Concrete Block - Concrete Block Concrete Block Concrete Block Concrete Block Frame - Wood Roof Area 106 ft2 ROOF Gable Roof Solar Area Color Absor. 1114 ft2 176 ft2 Medium 0.9 ATTIC Ventilation Vent Ratio (1 in) Vented 300 Space STAIRS MASTER BED MASTER BATH WIC MASTER 2ND FLR HALL BED SML CLOSE BED W LRG CLO Space Ext InaREAT ROO Ext InsuKITCHEN Ext IntikING ROO Ext IntUIWSTER BE Ext Indu1ASTER BA - Ext InRED SML CL - Ext InD W LRG - Ext In3REAT ROO - Ext InaiREAT ROO STAIRS Door Type Space Wood LIVING ROO Wood STAIRS CEILING Area Joist R -Value Tile Wood Carpet 11 0.5 0 0.5 11 0.5 0 0.5 SA Emitt Emitt Deck Pitch Tested Tested lnsul. (deg) No 0.9 No 0 18.4 RBS IRCC 1057.1 ft2 N R -Value Area 30 30 ft2 30 285 ft2 30 165 ft2 30 88 ft2 30 224 ft2 30 180 ft2 30 154 ft2 WALLS Cavity R -Value 4.1 N Framing Frac 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Truss Type Wood Wood Wood Wood Wood Wood Wood Width Height Sheathing Framing Solar Below R In Ft In Area R -Value Fraction_ A sor Grade% 15 0 9 0 135.0 ft2 0 0 0.5 0 4.1 10 7 9 0 95.3 ft2 0 0 0.5 0 4.1 5 0 9 0 45.0 ft2 0 0 0.5 0 4.1 14 0 9 0 126.0 ft2 0 0 0.5 0 4.1 10 0 9 0 90.0 ft2 0 0 0.5 0 4.1 10 7 9 0 95.3 ft2 0 0 0.5 0 4.1 13 7 9 0 122.3 ft2 0 0 0.5 0 4.1 73 0 9 0 657.0 ft2 0 0 0.5 0 4.1 81 0 9 0 729.0 ft2 0 0 0.5 0 11 24 0 9 0 216.0 ft2 0 0 0.5 0 DOORS Storms U -Value None .39 None .46 Width Height Area Ft In Ft In 3 7 6 8 23.9 ft2 2.8 8 22.4 ft2 EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 a WINDOWS Orientation shown is the entered orientation (=>) changed to As Built (rotated 180 degrees). / Wall Overhang �/ # Ornt ID Frame Panes NFRC U -Factor SHGC Area Depth Separation Int Shade Screening 1 W=>E 1 TIM Single (Tinted) Yes 1.08 0.38 24.0 ft2 1 ft 6 in 11 ft 0 in None None 2 W=>E 1 Metal Single (Tinted) Yes 1.08 0.49 30.0 ft2 1 ft 6 in 11 ft 0 in None None 3 W=>E 2 Metal Single (Tinted) Yes 1.08 0.49 15.0 ft2 1 ft 6 in 11 ft 0 in None None 4 W=>E 4 Metal Single (Tinted) Yes 1.08 0.49 30.0 ft2 1 ft 6 in 1 ft 0 in None None 5 W=>E 5 Metal Single (Tinted) Yes 1.08 0.49 9.0 ft2 1 ft 6 in 1 ft 0 in None None 6 E=>W 6 Metal Single (Tinted) Yes 1.08 0.49 15.0 ft2 2 ft 6 in 1 ft 0 in None None 7 E=>W 7 Metal Single (Tinted) Yes 1.08 0.49 15.0 ft2 2 ft 6 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 405 ft2 405 ft2 51 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0003 1484.9 81.52 153.31 .2548 5.1454 v HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 23 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 16 27.6 kBtu/hr 828 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 2ND FLR HALL0.92 40 gal 60.9 gal 120 deg None FSEC Cert # Company Name None None SOLAR HOT WATER SYSTEM System Model # DUCTS Collector Storage Collector Model # Area Volume FEF ft2 ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R -Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 1/13/2014 10:02 AM 1 ft2 Default Leakage 2ND FLR H (Default) (Default) EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar Apr Mayn Jun X Jul X Au X Se Oct j Nov Dec Heating [X Jan [X Feb IX Mar [ Apr i MaJun f Jul f Aug 4 SeOct 7< Nov 7< Dec Venting [ Jan [ Feb [X Mar [X Apr MayJun [ Jul ( Au [ SepX Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1/13/2014 10:02 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 • FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 9600 TOWN PARC CIRCLE NORTH PERMIT #: PARKLAND, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) Air leakage 402.4 Thermostat & controls 403.1 Ducts 403.2.2 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. At least one thermostat shall be provided for each separate heating and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Mechanical ventilation Swimming Pools & Spas Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. 403.5 Homes designed to operate at positive pressure or with mechanical ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two equipment or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 1/13/2014 10:02 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software i CHECK Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 76 The lower the EnergyPerformance Index, the more efficient the home. 9600 TOWN PARC CIRCLE NORTH, PARKLAND, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4: Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows** Description a. U -Factor: Sgl, U=1.08 SHGC: SHGC=0.49 b. U -Factor: Sgl, U=1.08 SHGC: SHGC=0.38 c. U -Factor: N/A SHGC: d. U -Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. Raised Floor c. N/A New (From Plans) Multi -family 1 3 No 1887 Insulation R=0.0 R=11.0 R= Area 114.00 ft2 24.00 ft2 ft2 ft2 1.717 ft. 0.471 Area 791.10 ft2 266.00 ft2 ft2 9. Wall Types a. Concrete Block - Ext Insul, Common b. Concrete Block - Ext Insul, Exterior c. Frame - Wood, Adjacent d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: 2ND FLR HALL Insulation R=4.1 R=4.1 R=11.0 R= Insulation R=30.0 R= R= 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: 96.00 72&,(-1 PARc, C tet Na P -4 -IN City/FL Zip: Po,4,t, -\ � C 330c.-) Area 1386.00 ft2 708.75 ft2 216.00 ft2 ft2 Area 1126.00 ft2 ft2 ft2 R ft2 6 200 kBtu/hr Efficiency 27.6 SEER:16.00 kBtu/hr Efficiency 23.0 COP:1.00 Cap: 40 gallons EF: 0.92 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Project Summary Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com Job: LH -A -ML Date: Mar 27, 2013 By: LINDSTROM Pro'ect Information For: LENNAR HOMES Notes: A MODEL MIRALAGO Desi • n Information Weather: Winter Design Conditions Outside db Inside db Design TD Heating Summary Structure Ducts Central vent (43 cfm) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 50 70 20 °F °F °F 9852 Btuh 1289 Btuh 951 Btuh 0 Btuh 0 Btuh 12092 Btuh Fort Lauderdale/Hollywood, FL, US Summer Design Conditions Simplified Average 0 Heating Cooling Area (ft2) 1887 1887 Volume (ft') 17313 17313 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 110 58 Heating Equipment Summary Make RHEEM/RUUD Trade Model 7.5 KW AHRI ref Efficiency 100 AFUE Heating input 0 kW Heating output 0 Btuh Temperature rise 0 °F Actual air flow 1000 cfm Air flow factor 0.090 cfm/Btuh Static pressure 0 in H2O Space thermostat Outside db Inside db Design TD Daily range Relative humidity Moisture difference 90 °F 75 °F 15 °F L 50 % 61 gr/Ib Sensible Cooling Equipment Load Sizing Structure Ducts Central vent (43 cfm) Blower 18641 Btuh 1823 Btuh 714 Btuh 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 20119 Btuh Latent Cooling Equipment Load Sizing Structure Ducts Central vent (43 cfm) Equipment latent load Equipment total load Req. total capacity at 0.74 SHR 3211 Btuh 851 Btuh 1808 Btuh 5870 Btuh 25989 Btuh 2.3 ton Cooling Equipment Summary Make RHEEM/RUUD Trade Cond 14AJM30A01 Coil "HLL-HM3617JA AHRI ref Efficiency 16 SEER Sensible cooling 20400 Btuh Latent cooling 7200 Btuh Total cooling 27600 Btuh Actual air flow 1000 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft® Right -Suite® Universal 2012 12.1.07 RSU08398 S:\PROJECTS ENERGY\A- MANUAL J\LH-A-ML 120.rup Calc = MJ8 Front Door faces N 2014 -Jan -13 09:38:16 Page 1 OnaftRIK Right -J® Worksheet Entire House Lindstrom Air Conditioning Job: LH -A -ML Date: Mar 27, 2013 By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com • 1 Room name Entire House GREAT ROOM 2 Exposed wall 55.5 ft 14.0 ft 3 Room height 9.2 ft 9.0 ft heat/cool 4 Room dimensions 14.0 x 20.6 ft 5 Room area 1887.0 ft' 287.8 ft2 Ty Construction number U -value Or (Btuh/ft2-°F) HTM Area (ft2) Load Area (ft2) Load (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 0.143 e 2.86 2.81 262 208 595 584 0 0 0 0 1A-hlom 1.270 e 25.40 60.62 30 13 762 1819 0 0 0 0 11 DO 0.390 e 7.80 12.03 24 24 187 289 0 0 0 0 13A-4ocs 0.143 w 2.86 2.81 446 338 967 950 135 81 232 228 11 10A -b 0.970 w 19.40 45.84 24 0 466 1100 24 0 466 1100 1A-hlom 1.270 w 25.40 65.83 9 1 229 592 0 0 0 0 1A-hlom 1.270 w 25.40 66.89 30 3 762 2007 0 0 0 0 1A-hlom 1.270 w 25.40 69.02 45 0 1143 3106 30 0 762 2071 12B-Obw 0.097 - 1.94 1.03 239 217 421 224 0 0 0 0 11D0 0.390 n 7.80 12.03 22 22 172 265 0 0 0 0 16D-30td 0.032 n 0.64 1.10 1126 1126 721 1238 0 0 0 0 19A-llcscp 0.073 - 1.03 0.78 266 266 275 206 0 0 0 0 22A -cpm 1.180 n 23.60 0.00 791 32 743 0 288 0 0 0 6 c) AED excursion 1990 1084 Envelope loss/gain 7442 14370 1459 4482 12 a) Infiltration 2410 951 460 181 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 2400 0 Subtotal (lines 6 to 13) 9852 18641 1919 4664 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 9852 18641 1919 4664 15 Duct loads 13% 10% 1289 1823 -0% 0% 0 0 Total room load 11141 20464 1919 4664 Air required (cfm) 1000 1000 172 228 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Right -Suite® Universal 2012 12.1.07 RSU08398 46-61/4 S:\PROJECTS ENERGY\A- MANUAL J\LH-A-ML 120.rup Calc = MJ8 Front Door faces: N 2014 -Jan -13 09:38:16 Page 1 Right -J® Worksheet Entire House Lindstrom Air Conditioning Job: LH -A -ML Date: Mar 27, 2013 By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name KITCHEN LIVING ROOM 2 Exposed wall 10.0 ft 18.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 13.0 x 11.0 ft 19.0 x 16.0 ft 5 Room area 143.0 ft2 304.0 ft2 Ty Construction U -value Or HTM Area (ft2) Load Area (82) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 13A-4ocs 0.143 e 2.86 2.81 0 0 0 0 45 21 60 59 1A-hlom 1.270 e 25.40 60.62 0 0 0 0 0 0 0 0 11 DO 0.390 e 7.80 12.03 0 0 0 0 24 24 187 289 13A-4ocs 0.143 w 2.86 2.81 95 80 229 225 0 0 0 0 11 i --G 10A -b 0.970 w 19.40 45.84 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 25.40 65.83 0 0 0 0 0 0 0 1A-hlom 1.270 w 25.40 66.89 0 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 25.40 69.02 15 0 381 1035 0 0 0 0 Pff- 12B-Obw 0.097 - 1.94 1.03 0 0 0 0 117 95 184 98 1--D 11D0 0.390 n 7.80 12.03 0 0 0 0 22 22 172 265 C 16D-30td 0.032 n 0.64 1.10 0 0 0 0 0 0 0 0 F 19A-llcscp 0.073 - 1.03 0.78 0 0 0 0 0 0 0 0 F 22A -cpm 1.180 n 23.60 0.00 143 0 0 0 304 18 425 0 6 c) AED excursion 279 -33 Envelope loss/gain 610 1539 1028 678 12 a) Infiltration 323 128 153 60 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants © 230 0 0 0 0 Appliances/other 1200 0 Subtotal (lines 6 to 13) 933 2867 1181 738 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 933 2867 1181 738 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 933 2867 1181 738 Air required (cfm) 84 140 106 36 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Pr wrightsoftw Right -Suite® Universal 2012 12.1.07 RSU08398 46-6p` S:\PROJECTS ENERGY\A- MANUAL J\LH-A-ML 120.rup Calc = MJ8 Front Door faces: N 2014 -Jan -13 09:38:16 Page 2 CL,24.4"1"WA1152111"11• CONOLTIOMIN6. ai Yui Right -J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name 2 Exposed wall 3 Room height 4 Room dimensions 5 Room area Ty Construction number Job: LH -A -ML Date: Mar 27, 2013 By: LINDSTROM STAIRS POWDER 10.0 ft 3.5 ft 20.0 ft heat/cool 9.0 ft heat/cool 10.0 x 3.0 ft 7.5 x 3.5 ft 30.0 ft2 26.3 ft2 U -value Or HTM Area (ft2) Load Area (ft2) Load (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W, 13A-4ocs 0.143 e 2.86 2.81 0 0 0 0 0 0 0 0 1A-hlom 1.270 e 25.40 60.62 0 0 0 0 0 0 0 0 D 11D0 0.390 e 7.80 12.03 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 2.86 2.81 0 0 0 0 0 0 0 0 11 -G 10A -b 0.970 w 19.40 45.84 0 0 0 0 0 0 0 0 -G 1A-hlom 1.270 w 25.40 65.83 0 0 0 0 0 0 0 0 - G 1A-hlom 1.270 w 25.40 66.89 0 0 0 0 0 0 0 0 -G 1A-hlom 1.270 w 25.40 69.02 0 0 0 0 0 0 0 0 P 12B-Obw 0.097 - 1.94 1.03 90 90 175 93 32 32 62 33 I ---D 11D0 0.390 n 7.80 12.03 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.64 1.10 30 30 19 33 0 0 0 0 F 19A-llcscp 0.073 - 1.03 0.78 0 0 0 0 0 0 0 0 F 22A -cpm 1.180 n 23.60 0.00 30 10 236 0 26 4 83 0 6 c) AED excursion -5 -1 Envelope loss/gain 430 121 145 32 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 430 121 145 32 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 430 121 145 32 15 Duct loads 23% 18% 98 21 -0% 0% 0 0 Total room load 527 142 145 32 Air required (cfm) 47 7 13 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrightsoft' Right -Suite® Universal 2012 12.1.07 RSU08398 ACC;p'` S:\PROJECTS ENERGY\A- MANUAL J\LH-A-ML 120.rup Calc = MJ8 Front Door faces: N 2014 -Jan -13 09:38:16 Page 3 Right -J® Worksheet .,. C°4°,„°., Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name 2 Exposed wall 3 Room height 4 Room dimensions 5 Room area Job: LH -A -ML Date: Mar 27, 2013 By: LINDSTROM MASTER BED MASTER BATH Oft Oft 9.0 ft heat/cool 9.0 ft heat/cool 25.5 x 10.0 ft 15.0 x 11.0 ft 255.0 ft2 165.0 ft2 Ty Construction U -value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 e 2.86 2.81 0 0 0 0 0 0 0 0 -G 1A-hlom 1.270 e 25.40 60.62 0 0 0 0 0 0 0 0 D 11 DO 0.390 e 7.80 12.03 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 2.86 2.81 126 96 275 270 90 81 232 228 11 -G 10A -b 0.970 w 19.40 45.84 0 0 0 0 0 0 0 0 - G 1A-hlom 1.270 w 25.40 65.83 0 0 0 0 9 1 229 592 -G 1A-hlom 1.270 w 25.40 66.89 30 2 762 2007 0 0 0 0 -G 1A-hlom 1.270 w 25.40 69.02 0 0 0 0 0 0 0 0 P 12B-Obw 0.097 - 1.94 1.03 0 0 0 0 0 0 0 0 1D 11D0 0.390 n 7.80 12.03 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.64 1.10 255 255 163 280 165 165 106 181 F 19A-llcscp 0.073 - 1.03 0.78 0 0 0 0 0 0 0 0 F 22A -cpm 1.180 n 23.60 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 685 205 Envelope loss/gain 1200 3242 566 1206 12 a) Infiltration 429 169 306 121 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1629 3871 872 1327 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1629 3871 872 1327 15 Duct loads 23% 18% 370 682 23% 18% 198 234 Total room load 1999 4554 1070 1561 Air required (cfm) 179 223 96 76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft` Right -Suite® Universal 2012 12.1.07 RSU08398 'CC` S:\PROJECTS ENERGY\A- MANUAL J\LH-A-ML 120.rup Calc = MJ8 Front Door faces: N 2014 -Jan -13 09:38:16 Page 4 cRe-sitideiTiwoosit., Right -J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 1 Room name 2 Exposed wall 3 Room height 4 Room dimensions 5 Room area Ty Construction number 13A -flocs 1A-hlom 11 D0 13A -flocs 1 OA -b 1 A -h 1 om 1A-hlom 1 A -h 1 om 12B-Obw 1100 16D-30td 19A-1lcscp 22A -cpm 6 c) AED excursion Envelope loss/gain 12 a) Infiltration b) Room ventilation 13 Internal gains: Subtotal (lines 6 to 13) Less extemal load Less transfer Redistribution 14 Subtotal 15 Duct loads Total room load Air required (cfm) U -value Or (Btuh/ft2-°F) 954-420-0064 Web: www.lindstromair.com WIC MASTER 0 ft heat/cool x 8.0 ft 9.0 ft 11.0 88.0 ft2 Job: LH -A -ML Date: Mar 27, 2013 By: LINDSTROM 2ND FLR HALL Oft heat/cool x 10.0 ft 9.0 ft 19.4 194.0 ft2 Area (ft2) or perimeter (ft) Gross N/P/S HTM Area (ft2) Load Load (Btuh/ft2) or perimeter (ft) (Btuh) (Btuh) Heat Cool Gross N/P/S Heat Cool Heat Cool 0.143 e 2.86 2.81 0 0 0 0 0 0 0 0 1.270 e 25.40 60.62 0 0 0 0 0 0 0 0 0.390 e 7.80 12.03 0 0 0 0 0 0 0 0 0.143 w 2.86 2.81 0 0 0 0 0 0 0 0 0.970 w 19.40 45.84 0 0 0 0 0 0 0 0 1.270 w 25.40 65.83 0 0 0 0 0 0 0 0 1.270 w 25.40 66.89 0 0 0 0 0 0 0 0 1.270 w 25.40 69.02 0 0 0 0 0 0 0 0 0.097 - 1.94 1.03 0 0 0 0 0 0 0 0 0.390 n 7,80 12.03 0 0 0 0 0 0 0 0 0.032 n 0.64 1.10 88 88 56 97 194 194 124 213 0.073 - 1.03 0.78 0 0 0 0 0 0 0 0 1.180 n 23.60 0.00 0 0 0 0 0 0, 0 0 Occupants @ 230 Appliances/other 0 23% 18% -4 56 93 O 0 O 0 0 0 56 93 O 0 O 0 O 0 56 93 13 16 69 109 6 5 0 23% 18% Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft` Right -Suite® Universal 2012 12.1.07 RSU08398 .4CCK S:\PROJECTS ENERGY\A- MANUAL J11 -A -ML 120.rup Calc = MJ8 Front Door faces: N -60 124 153 O 0 O 0 0 1200 124 1353 0 0 O 0 O 0 124 1353 28 239 152 1592 14 78 2014 -Jan -13 09:38:16 Page 5 Right -J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromair.com Job: LH -A -ML Date: Mar 27, 2013 By: LINDSTROM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BED SML CLOSET O ft 9.0 ft heat/cool 12.0 x 15.0 ft 180.0 ft' BED W LRG CLOSET O ft 9.0 ft heat/cool 14.0 x 11.0 ft 154.0 ft2 Ty Construction U -value Or HTM Area ft2) Load Area ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 e 2.86 2.81 95 80 229 225 122 107 306 301 1A-hlom 1.270 e 25.40 60.62 15 3 381 909 15 3 381 909 1100 0.390 e 7.80 12.03 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 2.86 2.81 0 0 0 0 0 0 0 0 11 10A -b 0.970 w 19.40 45.84 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 25.40 65.83 0 0 0 0 0 0 0 0 -G 1A-hlom 1.270 w 25.40 66.89 0 0 0 0 0 0 0 0 -G -G 1A-hlom 1.270 w 25.40 69.02 0 0 0 0 0 0 0 0 P 12B-Obw 0.097 - 1.94 1.03 0 0 0 0 0 0 0 0 1-D 11130 0.390 n 7.80 12.03 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.64 1.10 180 180 115 198 154 154 99 169 F 19A-llcscp 0.073 - 1.03 0.78 133 133 138 103 133 133 138 103 F 22A -cpm 1.180 n 23.60 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -76 -80 Envelope loss/gain 863 1359 923 1403 12 a) Infiltration 323 128 415 164 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants © 230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1186 1716 1339 1796 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1186 1716 1339 1796 15 Duct loads 23% 18% 269 303 23% 18% 304 317 Total room load 1455 2019 1642 2113 Air required (cfm) 131 99 147 103 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right -Suite® Universal 2012 12.1.07 RSU08398 ACh'` S:\PROJECTS ENERGY'- MANUAL J\LH-A-ML 120.rup Calc = MJ8 Front Door faces: N 2014 -Jan -13 09:38:16 Page 6 Right -J® Worksheet •I• CONDITIONING. INC Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax. 954-420-0064 Web: www.lindstromair.com Job: LH -A -ML Date: Mar 27, 2013 By: LINDSTROM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area 2ND FLR BATH 0 ft 9.0 ft heat/cool 10.0 x 6.0 ft 60.0 ft2 Ty Construction number U -value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area ft2) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VV 13A flocs 0.143 e 2.86 2.81 0 0 0 0 1A-hlom 1.270 e 25.40 60.62 0 0 0 0 11 DO 0.390 e 7.80 12.03 0 0 0 0 D . W 13A-4ocs 0.143 w 2.86 2.81 0 0 0 0 11 —G 10A -b 0.970 w 19.40 45.84 0 0 0 0 —G 1A-hlom 1.270 w 25.40 65.83 0 0 0 0 —G 1A-hlom 1.270 w 25.40 66.89 0 0 0 0 —G 1A-hlom 1.270 w 25.40 69.02 0 0 0 0 P 1—D 12B-Obw 0.097 - 1.94 1.03 0 0 0 0 11D0 0.390 n 7.80 12.03 0 0 0 0 C 16D-30td 0.032 n 0.64 1.10 60 60 38 66 F 19A-llcscp 0.073 - 1.03 0.78 0 0 0 0 F 22A -cpm 1.180 n 23.60 0.00 0 0 0 0 6 c) AED excursion -3 Envelope loss/gain 38 63 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants © 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 38 63 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 38 63 15 Duct loads 23% 18% 9 11 Total room load 47 74 Air required (cfm) 4 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right-Suitee Universal 2012 12.1.07 RSU08398 'CC` S:\PROJECTS ENERGYIA- MANUAL J1LH-A-ML 120.rup Calc = MJ8 Front Door faces: N 2014 -Jan -13 09:38:16 Page 7