Loading...
HomeMy WebLinkAbout2007010096-Product Approval114 - Checklist Print PERMIT NUMBER: 2007010096 N/A 9/28/2007 BLD15 **FOR MASONRY FENCE Foundation Size 1819.2 & Reinforcement 1819.3; Walls - Reinforcement; Beams - prescriptive 2121; Beams - unit masonry 2122; Top of footer depth below grade 16" 1819.2.3 NO 9/28/2007 BLD15 **FOR CHAIN LINK FENCE See Table 2224 SEE N N€ eC 3 N/A 9/28/2007 BLD15 **FOR WOOD FENCE 2328: maximum 6' high by this section may be designed for 75mph fastest mile or 90mph 3 -second gust 1611.2.1; 4 x 4 posts embedded 2' into concrete footing 10" in diameter, Lumber grade #2 or better 2328.2 N/A 9/28/2007 BLD15 Wood Fence footing o/c spacing for fence 6' high is 4' o/c; 5' high 5' o/c; 4' high 6' o/c 2328.3; posts of naturally durable or pressure treated 2326.1 N/A N/A N/A N/A 9/28/2007 BLD15 **ALUMINUM RAILING 9/28/2007 BLD15 6. RETAINING WALL 1832 9/28/2007 BLD15 7. PERMIT TO RELOCATE POOL SAFETY BARRIER FENCE: Protection needs to be shown for windows and doors opening out to pool deck area, or child barrier around pool 360 degrees, if fence is relocated from original approved position. 9/28/2007 BLD15 8. Plans Examiner: IF pool barrier fence is inclusive of "existing" fence section(s), fence contractor to CERTIFY that the existing portion(s) of fence comply with the requirements for the pool barrier based on a site visit, site-specific to this permit City of Parkland Printed on 9/28/2007 4:47:20PM CD -Plus for Windows 95/98/NT Page 2 of 3 Printed By:ADM09 N/A - Checklist Print PERMIT NUMBER: 2007010096 9/28/2007 BLD15 9. Plans Examiner: For retrofit of a fence to existing pool finaled before the pool safety barrier requirements, effective date of 10-01-00, please mark the plans to indicate to inspector that replacement fence does not need to comply with the safety act. INFO 9/28/2007 BLD15 Updated 10-12-04 City of Parkland Printed on 9/28/2007 4:47:20PM Page 3 of 3 Printed By:ADM09 CD -Plus for Windows 95/98/NT PERMIT NBR: 2007010096 CITY OF PARKLAND BUILDING DEPARTMENT INSPECTION HISTORY PRINT JOB DESC: SITE WORK - SITE LIGHTING. LANDSCAPING. JOB LOCATION: 9909 OLD CLUB RD SUBDIVISION: MASTER NBR: WATER: OWNER NAME: CERT NBR: 1063 / PARKLAND GOLF & COUNTRY CLUB - GOLF C BLOCK: 2007010096 UNIT: TRACT: 105 SEWER: COA: TOLL PARKLAND GSC LLC 7474 DBA: TOLL ORLANDO LIMITED PARTNERSHIP CONTACT PHONE: CONTACT NAME: IMPORTANT DATES: APPLICATION 1/9/2007 DIRECTIONS: ADDTL INFO: SUBCONTRACTORS CERT NBR SUBPERMITS PERMIT NBR 2007010096 2007010105 2007010107 2007010108 2007010109 200701011,0- 2007080408 2007090222 2011050309 2012010043 FLOOD ZONE: APPROVAL 8/29/2007 SUB STATUS ISSUED 8/29/2007 IRR STATUS: LOT: TAZ: AH INSPECT JOB PHONE: (561)637-8890 JOB VALUE: CO EXPIRATION CANCEL 6/28/2012 START DATE END DATE STATUS STATUS TYPE INSPECT CS CANCEL EL VOID PL ISSUED LS ISSUED SK MP FN -APPLY APPLY/ CANCEL CANCEL EL ISSUED EL City of Parkland SUB CLASS DBA $1,500,000.00 EXTENDED EXPIRATION 5/12/2009 CERT NBR DBA JOB DESC (7:47,4 TO LL'ORLANDQ LIMITED SITE WORK - SITE LIGHTING, LANDSCAPID 5567 THOMPSON ELECTRICAL IN ELEC SUB 7474 TOLL ORLANDO LIMITED P LANDSCAPING (C OF C FROM WCI TO TOLL) 318 AQUAMATIC SPRINKLER SY IRRIGATION - EXISTING PUMP 6357 WCI COMMUNITIES INC 1667 COMET FENCE CORP 7608 DEL AIR ELECTRICAL SER COC 7559 CARNEY ELECTRIC INC COC ( FOR DUMPSTER RETAIING WALL DUE TO CHANGE IN GRADE TEMPORARY CHAIN LINK AROUND CLUBHOUSE 5 -?e 6 a 3 ) 6 Printed on: 4/4/2012 3:54:45PM CD -Plus for Windows CDPR2036 Page 1 of 3 Printed By: ADM02 FEES FEE CODE STATUS BRWD POSTED PLRST POSTED RECRE2 POSTED RECRE3 POSTED STRCT POSTED ZONE2 POSTED CHG01 POSTED RPCD POSTED VIOLATI POSTED RENW POSTED PARTP POSTED PARTP POSTED CHG01 POSTED RPCD POSTED PARTP POSTED EXTEND POSTED CHG01 POSTED RPCD POSTED DESCRIPTION BROWARD COUNTY SURCHARGE PLAN REVIEW STRUCTURAL LARGE SHEET SURCHARGE COMMERCIAL RECORDS STORAGE STRUCTURAL ZONING REVIEW CHANGE OF CONTRACTOR REPLACEMENT CARD FNL INSP REQUIRED WRK DONE EXPIRED PERMIT RENEWAL PARTIAL INSPECTION FEE PL PARTIAL INSPECTION FEE PL CHANGE OF CONTRACTOR REPLACEMENT CARD PARTIAL INSPECTION FEE PL PERMIT EXTENSION CHANGE OF CONTRACTOR REPLACEMENT CARD REQ CLASS DESCRIPTION/REMARKS 260 EL 101 ST 181 ST 441 PL 441 PL 441 PL 441 PL 441 PL 441 PL 441 PL 441 PL 441 PL 441 PL 903 EN 903 EN 30 DAY FOR TESTING NOTICE OF COMMENCEMENT SIDEWALK AMOUNT DUE 525.00 330.00 15.00 95.00 2,020.00 70.00 60.00 20.00 200.00 1,010.00 60.00 70.00 60.00 20.00 70.00 70.00 90.00 25.00 ENTER DATE 8/21/2007 8/21/2007 8/21/2007 8/21/2007 8/21/2007 8/21/2007 1/28/2008 1/28/2008 3/3/2008 3/10/2008 6/12/2008 8/27/2008 9/16/2008 9/16/2008 11/13/2008 2/4/2009 1/18/2011 1/18/2011 PRI REQ DATE RESULT CODE RES DATE INSPECTOR 0 1 9/6/2007 40 1 7/22/2011 90 IRRIGATION - ROUGH 1 5/8/2008 91 inspected 3" main from entrace to around the building to the right of building 5/8/08 inspection 1 of 15 IRRIGATION - ROUGH 1 5/30/2008 91 THIS IS A REINSPECTION inspection 2 of 15 inspected main from rear by bridge to lest side of building rps IRRIGATION - ROUGH 1 6/12/2008 91 THIS IS A REINSPECTION ne back of building to east side to south IRRIGATION - ROUGH 1 8/27/2008 91 THIS IS A REINSPECTION THIS IS A REINSPECTION north east back of building to east side partial fee applied. far suth from bldg.partil fee applied IRRIGATION - ROUGH 1 11/13/2008 91 THIS IS A REINSPECTION main tie in at rear of bldg. (will need pressure test on main) IRRIGATION - ROUGH 1 2/8/2011 91 THIS IS A REINSPECTION (will need pressure test on main) IRRIGATION - ROUGH 1 2/10/2011 THIS IS A REINSPECTION IRRIGATION - ROUGH 1 7/1/2011 THIS IS A REINSPECTION IRRIGATION - ROUGH 1 12/14/2011 THIS IS A REINSPECTION IRRIGATION - ROUGH 1 2/16/2012 THIS IS A REINSPECTION ENG SIDEWALK / CURBS 1 7/22/2011 ENG SIDEWALK / CURBS 9/6/2007 7/25/2011 5/8/2008 PAID DATE 8/29/2007 8/29/2007 8/29/2007 8/29/2007 8/29/2007 8/29/2007 1/30/2008 1/30/2008 3/10/2008 3/10/2008 6/13/2008 12/4/2008 9/16/2008 9/16/2008 12/4/2008 2/4/2009 1/18/2011 1/18/2011 ADM02 BLD25 PLB05 just past the bridge in rear 5/30/2008 PLB05 5/30/08 6/12/2008 PLB04 east side partial. 8/27/2008 PLB04 to south east side partial. 11/13/2008 PLB04 2/8/2011 MECO5 91 2/10/2011 MECO5 91 7/5/2011 MECO5 91 12/14/2011 MECO5 90 2/16/2012 MECO5 8/8/2011 ENG09 1 8/15/2011 90I 8/15/2011 ENG05 91 City of Parkland Printed on: 4/4/2012 3:54:45PM CD -Plus for Windows CDPR2036 Page 2 of 3 Printed By: ADM02 269 EL 269 EL 269 EL 270 EL 270 EL 270 EL 237 EL 237 EL 271 EL 279 EL 279 EL 455 PL 503 LS 703 ST 703 ST 902 ST 902 ST 999 PT THIS IS A REINSPECTION TIERRA conducted the Field Testing on Monday, August 15th 2011 @ 9:00 am The Modified Protor Test (T-180) RESULTS = 122pcf ® 10.0% Optimum Moisture Density for Compaction had to reach 98% for a "PASSED" value. Field Test #1 - 125pcf @ 10.1% optimum moisture; 102.4% (PASSED) Field Test #2 - 117pcf (4) 7.5% optimum moisture; 95.6% (test FAILED) Field Test #3 - 123.4pcf @ 8.0% optimum moisture; 101.1% (PASSED) Concrete to be poured within the next 24 - 48hrs as per TIERRA convesation with General Contractor. LIGHT POLE BASE INSTALLATION 3 3/16/2012 81 no plans on site LIGHT POLE BASE INSTALLATION 3 3/19/2012 74 THIS IS A REINSPECTION need revised plans LIGHT POLE BASE INSTALLATION 3 3/30/2012 THIS IS A REINSPECTION PARKING AREA U.G ROUGH 3 3/16/2012 no plans on site PARKING AREA U.G ROUGH 3 3/19/2012 THIS IS A REINSPECTION need revised plans PARKING AREA U.G ROUGH 3 3/30/2012 THIS IS A REINSPECTION SITE LIGHTING 7 THIS IS A REINSPECTION IGHTING 7 3/30/2012 fron -7'1`v e FINAL HOTOMETRIC CERTIFICAT TH S A REINSPECTION PHOTOMETR ION pending signed, sealed report 7 7 3/16/2012 ELE06 3/22/2012 ELE02 50 3/30/2012 ELE02 81 3/16/2012 ELE06 74 3/22/2012 ELE02 90 3/30/2012 ELE02 91 3/30/2012 ELE02 7 4/3/2012 91 IRRIGATION - FINAL 7 4/5/2012 .day �,c� - �e�„ o .lan for new location fo tie into supply 7 FINAL FENCE THIS IS A REINSPECTION for dumpster gate 4-3-12 Gates not inst FINAL FENCE for dumpster gat car, no AP RAMP lled THIS IS A PECTION Dectable warnings required HANDICAP RAMP Dectable warnings required FINAL INSPECTION lled to be to be 7 7 4/3/2012 81 7 completed at 7 completed at 9 front entry of building. 4/3/2012 81 front entry of building. 4/3/2012 ELE02 4/3/2012 BLD16 4/3/2012 BLD16 City of Parkland Printed on: 4/4/2012 3:54:45PM CD -Plus for Windows CDPR2036 Page 3 of 3 Printed By: ADM02 Ch; cklist Print CDPR1014 - Checklist Print PLAN.MP - MISCELLANEOUS STRUCTURAL - RETAINING WALL STATUS DATE USER INFO 9/7/2007 BLD16 PERMIT NUMBER: 2007010096 ITEM PLAN REVIEW BY: WTH first review 9-7-07 NO 9/7/2007 BLD16 DESCRIPTION OF WORK: RETAINING WALL YES YES YES N/A N/A N/A N/A NO Permit Application submitted for retaining wall only Plans submitted indicate several changes in plans that affect other disiplines. Please see Item # 8 for further details. 9/7/2007 BLD16 1. 2 sets of plans signed and sealed by architect or engineer. Architect Steve Phil Sammons Regestered Landscape Architect Engineer Mark Leblanc P.E. 9/7/2007 BLD16 2. Site plan or survey. New survey and Pages GR -1, PL -1, PL -2, PD -1, PD -2 and Engineering page 1 of 1 for retaining wall submitted. 9/7/2007 BLD16 3. Check permit type; GC required to pull permit? 9/7/2007 BLD16 4. If on septic tank, Health Dept stamps for addition. 9/7/2007 BLD16 5. DPEP stamps & form; Note this is mandatory for CONSTRUCTION TRAILERS 9/7/2007 BLD16 6. Energy calculations for additions under air. 9/7/2007 BLD16 7. SHUTTERS OVER OPENINGS REQ.FOR ADDITIONS. 9/7/2007 BLD16 8. Items that require clarification or revision: City of Parkland Printed on 4/5/2012 9:33:12AM CD -Plus for Windows 95/98/NT Page 1 of 2 Printed By:ADM02 CDPR1014 - Checklist Print 56 p 3;• 2. w5 PERMIT NUMBER: 2007010096 1. New page CR -1 submitted shows 12 wide concrete path (cart path). and refers to civil drawings for cross section. Please note: there is no cross section for cart path in submitted plans or plans in city file. Please note; this change is not indicated on permit application. 2. Emergency turnaround area is not labeled on new sheet GR -1 and has been moved further away from building. on sheet GR -1 and new survey submitted.Please note; this change has not been indicated on permit application . 3. New landscape plans submitted . This change not indicated on permit application. 4. New riser steps are shown on revised page GR -1 at pathway between clubhouse and cartpath. there are no details for steps. This change not indicated on permit application. This change not shown on existing approved plans on pages LA -1 and ADA -1. 5. length of Retaining Wall not shown on plans 6. Locations of 12 in. wide and 8 in. wide retaining wall not shown on plans. 7. Depth of concrete for footers not shown on plans. See engineering page. 8. Safeguards are required at retaining wall where differences in level exceed 30 in. and are required to be shown on plans FBC 1618.4.1 City of Parkland Printed on 4/5/2012 9:33:12AM CD -Plus for Windows 95/98/NT Page 2 of 2 Printed By:ADM02 ;hecklist Print JPR1014 - Checklist Print PLAN.ZNCOMM - ZONING CHECKLIST FOR COMMERCIAL STATUS DATE USER NO 1/26/2007 PLN05 PEND PEND PEND PEND PEND PEND PEND PEND PERMIT NUMBER: 2007010096 ITEM 1. FRONT SETBACK does not match approved site plan. 2. SIDES SETBACK 3. REAR SETBACK 4. HEIGHT OF STRUCTURE 5. ZONING DISTRICT 6. DRIVEWAY LOCATION 7. WELL AND SEPTIC LOCATION 8. Check Legal Discription and address 9. review out buildings T of Parkland Printed on 1/2 007 11:06:17AM 1us for Windows 95/98/NT Page 1 of 1 Pri e By:ADM09 :hecklist Print 2DPR1014 - Checklist Print PLAN.ENGSFR - SFR DRAINAGE PTE & RANCHES STATUS PEND PEND DATE 1/11/2007 City of Parkland CD -Plus for Windows 95/98/NT Page 1 of 1 Printed By:ADM09 USER ENG03 PERMIT NUMBER: 2007010096 ITEM 1. PURSUANT TO PARKLAND CITY CODE 16-22 FOR PINETREE NORTH & 16-42 FOR PINETREE SOUTH: Architect's drainage plan submitted showing drainage to sides and from front of property to rear drainage swale, typical 1/11/2007 A Land Development/Engineering Permit is required prior to issuance of a building permit. Please contact the Public Services Department to process the permit. 2. Easements: Pinetree, dedicated 5' side swale easements and 17.5 dedicated drainage swale at rear of property. Printed on 1/26/2007 11:06:28AM E?JkAMM Consulting Headauarters Office 1407 West Newport Center Drive Deerfield Beach, FL 33442 954-949-2200 954-949-2201 FAX August 2, 2007 City of Parkland Building Department — Electrical Plans Review 6600 University Drive Parkland, FL 33067 ATTN: STEVE MITCHELL RE: PARKLAND GOLF AND COUNTRY CLUB 1. Art Kamm, P.E.-LEED® Bradly Brown, P.E.-LEED® Rick Gonzalez Lon T. Carter, P.E. Mike Pella, P.E. Scott Meriwether, P.E. Nevena Parsons, P.E. - LEED® Enrique Uribe, P.E. Gordon Myers, P.E.- LEED® Paul Bohres, P.E. REVISION #2 DATED 08/02/07 Comment: Panel schedules for each panel including wire size and ocp FBC BCAP 104.6.4.8.1. Response: Revised size of panel "LW1B", "LE1C: and "LE1AA". 5tAfecfaue 2. Comment: Provide detail for pole bases and handholds. (1) Provide dimensions for pole with luminaire from grad. (2) provide base details. Response: Provided required details. See revised Sheet E1.3. 3. Comment: Provide engineer's wind load cal for light poles. FBC Chapter 16 for hvhz. Response: Shall be submitted by Contractor. See note indicated under "Decorative Pole Detail" on Sheet E1.3. If you have any questions or require additional information, please contact this office. Sincerely, KAMM CONSULTING, INC. -67 Bill Weaver Project Manager BW:tas Florida 6859 Belfort Oaks Place Jacksonville, FL 32216 904-285-2009 904-285-3009 Fax Florida 1408 Orange Avenue Fort Pierce, FL 34950 772-595-1744 772-595-1745 Fax 2006-0313 (08.02.07)Rev 2 Itr.doc BRANCH OFFICES Florida 3808 Gunn Highway, Ste. C Tampa, FL 33618 813-265-9550 813-963-3187 Fax www.kammconsultino.com Georgia 2050 Marconi Drive, Ste. 300 Alpharetta, GA 30005 770-752-7083 770-752-7084 Fax Check ist Print CDPR1014 - Checklist Print PLAN.PLUMBING MISC - PLUMBING MISCELLANEOUS STATUS DATE USER ITEM 3/23/2007 PLB04 1. NEw 7.QAt4. FL )5 LE'5E4 Pm-Aclatt City of Parkland CD -Plus for Windows 95/98/NT PERMIT NUMBER: 2007010096 Irrigation: provide number of head provide approval letter from Broward cty. for lake usage for this area. provide pump location for project Printed on Page 1 of 1 /2067 12:41:27P nted By:ADM07 E?IRAMM Consulting Headquarters Office 1407 West Newport Center Drive Deerfield Beach, FL 33442 954-949-2200 954-949-2201 FAX Reply to: Deerfield Beach July 5, 2007 Steve Mitchell City of Parkland Building Department — Electrical Plans Review 6600 University Drive Parkland, FL 33067 Art Kamm, P.E.-LEED® Bradly Brown, P.E.-LEED® Rick Gonzalez Lon T. Carter, P.E. Mike Pella, P.E. Scott Meriwether, P.E. Nevena Parsons, P.E. - LEED® Enrique Uribe, P.E. Gordon Myers, P.E.- LEED® Paul Bohres, P.E. RE: PARKLAND GOLF AND COUNTRY CLUB SITE PERMIT NUMBER: 2007010096 Below are our responses to Building Department comments pertinent only to our portion of the design of the referenced project. ELECTRICAL: 6. Comment: Provide short circuit analysis FBC BCAP 104.6.4.8.1. Response: Provided short circuit analysis. See revised Sheet E1.1. 14. Comment: Provide detail for pole bases and handholes. Response: Provided requested details. See revised Sheet E1.3. 15. Comment: Show compliance with Parkland lighting ordinance Sec. statement of compliance. Response: Added requested Note. See Sheet E1.2. 4-53; include positive 16. Comment: Provide engineer's wind load calc for light poles. FBC Chapter 16 for HVHZ. Response: Added pole detail with Note. See Sheet E1.3. 21. Comment: Indicate compliance with Florida Energy Code requirements for electrical equipment. Response: Added Note #11. See electrical specifications Part IC on Sheet E0.1. Sincerely, KAM ��I�ING, I C. Bill eaver Project Manager BW:tas Florida 6859 Belfort Oaks Place Jacksonville, FL 32216 904-285-2009 904-285-3009 Fax Florida 1408 Orange Avenue Fort Pierce, FL 34950 772-595-1744 772-595-1745 Fax 2006-0313 (07.05.07) comments Itr.doc BRANCH OFFICES Florida 3808 Gunn Highway, Ste Tampa, FL 33618 813-265-9550 813-963-3187 Fax www.kammconsultina.com Georgia C 2050 Marconi Drive, Ste. 300 Alpharetta, GA 30005 770-752-7083 770-752-7084 Fax Checklist Print CDPR1014 - Checklist Print PLAN.ELCOM - ELECTRIC COMMERCIAL PERMIT NUMBER: 2007010096 STATUS DATE USER ITEM YES 4/3/2007 ELE02 1. site plan showing locations of structures and equip FBC BCAP 104.6.4.8.1 YES YES YES N/A YES YES YES N/A 4/3/2007 ELE02 2. architect / engineer signature and seal FBC BCAP 104.6.3.7 4/3/2007 ELE02 3. electrical floor plan matches structural 4/3/2007 ELE02 4. riser diagram showing size of service, feeder wire and conduit, overcurrent protection and grounding NEC 250 FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 5. mech plans to match load calc, exhaust fans located per mech plan 4/3/2007 ELE02 6. provide short circuit analysis FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 7. load calculations for service and each panel including general lighting load, equip and required receptacles FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 8. panel schedules for each panel including wire size and ocp FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 9. floor plan including location of all equip and circuitry of all devices FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 10. provide show window receptacles NEC 210.52 City of Parkland Printed on 6/7/2007 12:41:42PM CD -Plus for Windows 95/98/NT Page 1 of 3 Printed By:ADM07 CDPR1014 - Checklist Print N/A N/A N/A N/A YES N/A YES PERMIT NUMBER: 2007010096 4/3/2007 ELE02 11. GFI where required (rooftop, AC equip, kitchen, etc.) NEC 210.8 4/3/2007 ELE02 12. provide sign outlets with FEC compliant timeclock NEC 600.5/ Florida Energy Code 4/3/2007 ELE02 13. provide relevant material and equip listing 4/3/2007 ELE02 14. provide detail for pole bases and handholes 4/3/2007 ELE02 15. show compliance with Parkland lighting ord Sec 4-53 include positive statement of compliance 4/3/2007 ELE02 16. provide engineer's wind load calc for light poles FBC Chapter 16 for hvhz 4/3/2007 ELE02 17. verify fire -rating of electric rooms 4/3/2007 ELE02 18. provide ventilation for electric room 4/3/2007 ELE02 19. verify notes 4/3/2007 ELE02 20. seperate permit required for signs 4/3/2007 ELE02 22. verify panel locations and clearances City of Parkland Printed on 6/7/2007 12:41:42PM CD -Plus for Windows 95/98/NT Page 2 of 3 Printed By:ADM07 CDPR1014 - Checklist Print PERMIT NUMBER: 2007010096 4/3/2007 ELE02 21. indicate compliance with Florida Energy Code requirements for electrical equipment City of Parkland CD -Plus for Windows 95/98/NT Printed on 6/7/2007 12:41:42PM Page 3 of 3 Printed By:ADM07 The following are the responses to the City of Parkland Building Department comments for Permit # 2007010096. Fire Marshal Water mains. Fire Hydrant needs to be supplied with and 8" line up to the Hydrant. 8"x 6" Reducer has been relocated. See Sheet C-3 Minimum Coverage Over the Hydrant mains is 36" under roads. See Note on Sheet C-7 013 Provide Blue RPM's In the middle of the drive -aisle next to the hydrant See Sheet C-2 and C-3 Ken Mason 5. FBC 1820.3.6: Slab for Dumpster to be minimum 1' larger on all sides than receptacle and minimum 6" thick. See sheet C-5 1. Details provided on sheet C-5, however no dumpster location provided on site plan Gates and Note added. See sheets C-1, C-2 and C-3 2. Note service yard area appears to be enclosed, however the building plans for the structure do not show this as being the case. See Arch. For details 3. Please remove or void details on sheet C-5 which are not applicable to dumpster walls. Note deleted and details have been removed. See sheet C-5 and C-7 --:Theckiist Print CDPR1014 - Checklist Print PLAN.FR - REVIEW FIRE MARSHAL PERMIT NUMBER: 2007010096 STATUS DATE USER ITEM INFO 5/9/2007 FRM02 PLAN REVIEW BY: BRUCE BOWERS 954-344-1077 5/9/2007 FRM02 1. WATER MAINS Fire Hydrants need to supplied with an 8" line up to the hydrant 5/9/2007 FRM02 2.MINIMUM COVERAGE Over the hydrant mains is 36" under roads 5/9/2007 FRM02 3. PROVIDE BLUE RPM'S In the middle of the drive -aisle next to the hydrants. City of Parkland Printed on 6/7/2007 12:41:35PM CD -Plus for Windows 95/98/NT Page 1 of 1 Printed By:ADM07 Checklist Print CDPR1014 - Checklist Print PERMIT NUMBER: 2007010096 PLAN.FBC:SITE COMMERCIAL - SITE PLANS COMMERCIAL PROJECT STATUS DATE USER YES 6/7/2007 BLD15 YES YES YES N/A N/A ITEM PLAN REVIEW BY: KRM #HOURS 4 6/7/2007 BLD15 1. Two Sets Signed and Sealed Plans showing all buildings and facilities on property Engineering plans by John R McKune, PE sealed 7/31/06 Landscape plans by Steve Paul Sammons, Landscape architect sealed 9/22/07 6/7/2007 BLD15 2. FBC Chapter 11: Accessible Route complying with 11-4.3 into and through site from public transportation stops, streets or sidewalks, and from accessible parking spaces & loading zones, to accessible building entrance 6/7/2007 BLD15 3. FBC Chapter 11: Maximum slopes and cross -slopes specified for all parking spaces, walks,and ramps 6/7/2007 BLD15 4. FBC Table 600: Building Separation Distance Compliance 6/7/2007 BLD15 5. FBC 1820.3.6: Slab for Dumpster to be minimum 1' larger on all sides than receptacle and minimum 6" thick 1) Details provided on sheet C-5, however no dumpster location provided on site plan. 2) Note service yard area appears to be enclosed, however the building plans for the structure do not show this as being the case 3) Please remove or void details on sheet C-5 which are not applicable to site 6/7/2007 BLD15 6. FBC 2122.4: Letter of intent stating scope of work from Special Inspector, FL registered A/E, must inspect and certify reinforced masonry structures, applicable to dumspter walls 6/7/2007 BLD15 7. Outside Agency Approvals, i.e: Broward County, Copy of Application for construction of Lake on site; Health Department approval for construction of Lift Station or Septic System City of Parkland Printed on 6/7/2007 12:41:47PM CD -Plus for Windows 95/98/NT Page 1 of 2 Printed By:ADM07 CDPR1014 - Checklist Print INFO PERMIT NUMBER: 2007010096 6/7/2007 BLD15 8. Area Calculations for square footage of site, of paved area, of pervious area, linear feet of sidewalks Pervious area 88,363 sf = 2.03 acres Impervious area 93,389 sf = 2.14 acres Lineal ft of sidewalks: 4' = 291f, 5' = 681f, 6' = 6051f, 8' = 831f, 12' = 1701f City of Parkland Printed on 6/7/2007 12:41:47PM ,?D -Plus for Windows 95/98/NT Page 2 of 2 Printed By:ADM07 Checklist Print CDPR1014 - Checklist Print PLAN.ENGSFR - SFR DRAINAGE PTE & RANCHES STATUS PEND PEND DATE 1/11/2007 USER ENG03 PERMIT NUMBER: 2007010096 ITEM 1. PURSUANT TO PARKLAND CITY CODE 16-22 FOR PINETREE NORTH & 16-42 FOR PINETREE SOUTH: Architect's drainage plan submitted showing drainage to sides and from front of property to rear drainage swale, typical 1/11/2007 A Land Development/Engineering Permit is required prior to issuance of a building permit. Please contact the Public Services Department to process the permit. 2. Easements: Pinetree, dedicated 5' side swale easements and 17.5 dedicated drainage swale at rear of property. City of Parkland Printed on 6/7/2007 12:41:54PM CD --Plus for Windows 95/98/NT Page 1 of 1 Printed By:ADM07 Checklist Print CDFR1014 - Checklist Print PLAN.ELCOM - ELECTRIC COMMERCIAL STATUS DATE USER YES 4/3/2007 ELE02 YES YES YES N/A YES YES YES YES N/A PERMIT NUMBER: 2007010096 ITEM 1. site plan showing locations of structures and equip FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 2. architect / engineer signature and seal FBC BCAP 104.6.3.7 4/3/2007 ELE02 3. electrical floor plan matches structural 4/3/2007 ELE02 4. riser diagram showing size of service, feeder wire and conduit, overcurrent protection and grounding NEC 250 FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 5. mech plans to match load calc, exhaust fans located per mech plan 4/3/2007 ELE02 6. provide short circuit analysis FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 7. load calculations for service and each panel including general lighting load, equip and required receptacles FBC BCAP 104.6.4.8.1 8/10/2007 ELE02 8. panel schedules for each panel including wire size and ocp FBC BCAP 104.6.4.8.1 provided corrected E6.1 from building plans 4/3/2007 ELE02 9. floor plan including location of all equip and circuitry of all devices FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 10. provide show window receptacles NEC 210.52 City of Parkland Ali V Printed on 8 0/2007 11:39:08AM Page 1 of 3 ri ed By:ELE02 CDPR1014 - Checklist Print N/A N/A PERMIT NUMBER: 2007010096 4/3/2007 ELE02 11. GFI where required (rooftop, AC equip, kitchen, etc.) NEC 210.8 4/3/2007 ELE02 12. provide sign outlets with FEC compliant timeclock NEC 600.5/ Florida Energy Code INFO 7/11/2007 ELE02 13. provide relevant material and equip listing NO 8/10/2007 ELE02 14. provide detail for pole bases and handholes SEe ATco KAmm RCsPoasE sNEET" YES ✓1.provide dimensions for pole with luminaire from grade 8/10/07 include luminaire and base in dimension (see base detail) .provide base details 8/10/07 precast or poured in place? 4/3/2007 ELE02 15. show compliance with Parkland lighting ord Sec 4-53 include positive statement of compliance NO 8/10/2007 ELE02 N/A N/A YES N/A /rrAcjo 16. provide engineer's wind load calc for light poles FBC Chapter 16 for hvhz not provided t ed S t 4, c 4— 5C L+' T �'� 8/10/07 h P.r a FArrt.-)clf{tom 'LiI�' •I"s 4/3/2007 ELE02 17. verify fire -rating of electric rooms 4/3/2007 ELE02 18. provide ventilation for electric room 4/3/2007 ELE02 19. verify notes 4/3/2007 ELE02 20. seperate permit required for signs City of Parkland Printed on 8/10/2007 11:39:08AM Page 2 of 3 Printed By:ELE02 CDPR1014 - Checklist Print YES YES PERMIT NUMBER: 2007010096 4/3/2007 ELE02 22. verify panel locations and clearances 4/3/2007 ELE02 21. indicate compliance with Florida Energy Code requirements for electrical equipment City of Parkland Printed on 8/10/2007 11:39:08AM Page 3 of 3 Printed By:ELE02 c?JkAMM Consulting Headauarters Office 1407 West Newport Center Drive Deerfield Beach, FL 33442 954-949-2200 954-949-2201 FAX August 16, 2007 City of Parkland Building Department — Plans Review 6600 University Drive Parkland, FL 33067 Art Kamm, P.E.-LEED® Bradly Brown, P.E.-LEED® Rick Gonzalez Lon T. Carter, P.E. Mike Pella, P.E. Scott Meriwether, P.E. Enrique Uribe, P.E. Gordon Myers, P.E.- LEED® Paul Bohres, P.E. RE: PARKLAND GOLF AND COUNTRY CLUB Permit 2007010096 Below are our responses to Building Department comments pertinent only to our portion of the design of the referenced project. 14. Comment: Provide detail for pole bases and handholes. 1) Provide dimensions for pole with luminaire from grade — 8/11/07 include luminarie and base in dimension (see base detail). 2) Provide base details — 8/10/07 precast or poured in place? Response: 1) Provided requested details with dimensions. Refer to revised Sheet E1.3. 2) Provided base is precast type. Added note "precast 4500 psi concrete base". Refer to Sheet E1.3. 16. Comment; provided. Response; Provide engineer's wind load calc for light poles. FBC Chapter 16 for hvhz. Not Wind load calc for light poles are provided by structural engineer. If you have any questions or require additional information, please contact this office. Sincerely, KAMM CONSULTING, INC. Bill Weaver Project Manager BW:tas Florida 6859 Belfort Oaks Place Jacksonville, FL 32216 904-285-2009 904-285-3009 Fax Florida 1408 Orange Avenue Fort Pierce, FL 34950 772-595-1744 772-595-1745 Fax 2006-0313 (08.16.07) Rev 4.doc BRANCH OFFICES Florida 3808 Gunn Highway, Ste. C Tampa, FL 33618 813-265-9550 813-963-3187 Fax www.kammconsultino.com Georgia 2050 Marconi Drive, Ste. 300 Alpharetta, GA 30005 770-752-7083 770-752-7084 Fax Checklist Print CDPR1014 - Checklist Print \/ PERMIT NUMBER: 2007010096 PLAN.P.3C:SITE COMMERCIAL - SITE PLANS,C MMERCIAL PROJECT STATUS DATE USER YES 7/30/2007 BLD15 YES YES ITEM PLAN REVIEW BY:_KRM_#HOURS_4 2nd review 7/30/07 KRM 1 hr 6/7/2007 BLD15 1. Two Sets Signed and Sealed Plans showing all buildings and facilities on property Engineering plans by John R McKune, PE sealed 7/31/06 Landscape plans by Steve Paul Sammons, Landscape architect sealed 9/22/07 6/7/2007 BLD15 2. FBC Chapter 11: Accessible Route complying with 11-4.3 into and through site from public transportation stops, streets or sidewalks, and from accessible parking spaces & loading zones, to accessible building entrance 6/7/2007 BLD15 3. FBC Chapter 11: Maximum slopes and cross -slopes specified for all parking spaces, walks,and ramps 6/7/2007 BLD15 4. FBC Table 600: Building Separation Distance Compliance )/2007 BLD15 5. FBC 1820.3.6: Slab for Dumpster to be minimum 1' larger on all sides than receptacle and minimum 6" thick 1) Details provided on sheet C-5, however no dumpster location provided on site plan. P,Ut 2) Note service yard area appears to be enclosed, however the building plans for the structure do not show this as being the case 3) Please remove or void details on sheet C-5 which are not applicable to site BLD15 7/30/07 Items 1 and 3 above have been corrected Item 2 above has not been addressed. Require structural drawings for the footings and walls surrounding the Service Yard 6. FBC 2122.4: Letter of intent stating scope of work from Special Inspector, FL registered A/E, must inspect and certify reinforced masonry structures, applicable to dumspter walls Printed on 7/31/2007 2:39:41PM Page 1 of 2 Printed By:ADM09 CDPR1014 - Checklist Print PERMIT NUMBER: 2007010096 N/A 6/7/2007 BLD15 7. Outside Agency Approvals, i.e: Broward County, Copy of Application for construction of Lake on site; Health Department approval for construction of Lift Station or Septic System INFO 6/7/2007 BLD15 8. Area Calculations for square footage of site, of paved area, of pervious area, linear feet of sidewalks Pervious area 88,363 sf = 2.03 acres Impervious area 93,389 sf = 2.14 acres Lineal ft of sidewalks: 4' = 291f, 5' = 681f, 6' = 6051f, 8' = 831f, 12' = 1701f City of Parkland Printed on 7/31/2007 2:39:41PM CD -Plus for Windows 95/98/NT Page 2 of 2 Printed By:ADM09 Checklist Print CDPR1014 - Checklist Print PLAN.ELCOM - ELECTRIC COMMERCIAL PERMIT NUMBER: 2007010096 STATUS DATE USER ITEM YES 4/3/2007 ELE02 1. site plan showing locations of structures and equip FBC BCAP 104.6.4.8.1 YES YES YES N/A YES YES 4/3/2007 ELE02 2. architect / engineer signature and seal FBC BCAP 104.6.3.7 4/3/2007 ELE02 3. electrical floor plan matches structural 4/3/2007 ELE02 4. riser diagram showing size of service, feeder wire and conduit, overcurrent protection and grounding NEC 250 FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 5. mech plans to match load calc, exhaust fans located per mech plan 4/3/2007 ELE02 6. provide short circuit analysis FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 7. load calculations for service and each panel including general lighting load, equip and required receptacles FBC BCAP 104.6.4.8.1 N0 7/11/2007 ELE02 8. panel schedules for each panel including wire size and ocp FBC BCAP 104.6.4.8.1 provided corrected E6.1 from building plans NEw SAEt- tOStRTEP YES N/A 4/3/2007 ELE02 9. floor plan including location of all equip and circuitry of all devices FBC BCAP 104.6.4.8.1 4/3/2007 ELE02 10. provide show window receptacles NEC 210.52 City of Parkland Printed on 7/31/2007 2:39:58PM CD -Plus for Windows 95/98/NT Page 1 of 3 Printed By:ADM09 CDPR1014 - Checklist Print PERMIT NUMBER: 2007010096 N/A N/A INFO NO 4/3/2007 ELE02 11. GFI where required (rooftop, AC equip, kitchen, etc.) NEC 210.8 4/3/2007 ELE02 12. provide sign outlets with FEC compliant timeclock NEC 600.5/ Florida Energy Code 7/11/2007 ELE02 13. provide relevant material and equip listing 7/11/2007 ELE02 14. provide detail for pole bases and handholes N tiw S I4 €t E 13 Tom-rE0 YES NO 1.provide dimensions for pole with luminaire from grade 2.provide base details 4/3/2007 ELE02 15. show compliance with Parkland lighting ord Sec 4-53 include positive statement of compliance 4/3/2007 ELE02 NtW ci4ccC f1.3 rrNi ED N/A N/A YES N/A YES 16. provide engineer's wind load calc for light poles FBC Chapter 16 for hvhz 4/3/2007 ELE02 17. verify fire -rating of electric rooms 4/3/2007 ELE02 18. provide ventilation for electric room 4/3/2007 ELE02 19. verify notes 4/3/2007 ELE02 20. seperate permit required for signs 4/3/2007 ELE02 22. verify panel locations and clearances City of Parkland Printed on 7/31/2007 2:39:58PM CD -Plus for Windows 95/98/NT Page 2 of 3 Printed By:ADM09 CDPR1014 - Checklist Print YES PERMIT NUMBER: 2007010096 4/3/2007 ELE02 21. indicate compliance with Florida Energy Code requirements for electrical equipment City of Parkland CD -Plus for Windows 95/98/NT Printed on 7/31/2007 2:39:58PM Page 3 of 3 Printed By:ADM09 Checklist Print CDPR1014 - Checklist Print PERMIT NUMBER: 2007010096 PLAN.FBC:SITE COMMERCIAL - SITE PLANS COMMERCIAL PROJECT STATUS DATE USER ITEM YES 8/7/2007 BLD15 PLAN REVIEW BY:_KRM_#HOURS_4 YES YES YES N/A YES YES 2nd review 7/30/07 KRM 1 hr 3rd review 8/6/07 KRM 1 hr 6/7/2007 BLD15 1. Two Sets Signed and Sealed Plans showing all buildings and facilities on property Engineering plans by John R McKune, PE sealed 7/31/06 Landscape plans by Steve Paul Sammons, Landscape architect sealed 9/22/07 6/7/2007 BLD15 2. FBC Chapter 11: Accessible Route complying with 11-4.3 into and through site from public transportation stops, streets or sidewalks, and from accessible parking spaces & loading zones, to accessible building entrance 6/7/2007 BLD15 3. FBC Chapter 11: Maximum slopes and cross -slopes specified for all parking spaces, walks,and ramps 6/7/2007 BLD15 4. FBC Table 600: Building Separation Distance Compliance 8/6/2007 BLD15 5. FBC 1820.3.6: Slab for Dumpster to be minimum 1' larger on all sides than receptacle and minimum 6" thick 1) Details provided on sheet C-5, however no dumpster location provided on site plan. 2) Note service yard area appears to be enclosed, however the building plans for the structure do not show this as being the case 3) Please remove or void details on sheet C-5 which are not applicable to site 7/30/07 Items 1 and 3 above have been corrected Item 2 above has not been addressed. Require structural drawings for the footings and walls surrounding the Service Yard Service yard walls are part of building plans see 5100 7/30/2007 BLD15 6. FBC 2122.4: Letter of intent stating scope of work from Special Inspector, FL registered A/E, must inspect and certify reinforced masonry structures, applicable to dumspter walls City of Parkland Printed on 8/20/2007 4:05:11PM CD -Plus for Windows 95/98/NT Page 1 of 2 Printed By:ADM04 CDPR1014 - Checklist Print N/A INFO PERMIT NUMBER: 2007010096 6/7/2007 BLD15 7. Outside Agency Approvals, i.e: Broward County, Copy of Application for construction of Lake on site; Health Department approval for construction of Lift Station or Septic System 8/7/2007 BLD15 8. Area Calculations for square footage of site, of paved area, of pervious area, linear feet of sidewalks Pervious area 88,363 sf = 2.03 acres Impervious area 93,389 sf = 2.14 acres City of Parkland CD -Plus for Windows 95/98/NT Asphault areas 49,600 sf Paver areas 8,000 sf Lineal ft of sidewalks: 4' = 291f, 5' = 681f, 6' = 6051f, 8' = 831f, 12' = 1701f Printed on 8/20/2007 4:05:11PM Page 2 of 2 Printed By:ADM04