BLDG1404-0010-PlansCHAPTER 15, SECTION 1524 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope_ As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain 10 the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initials in the designated space indicates that the item has been explained. 1_ Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High -Velocity Hurricane Zone) are for the purpose of providing the roofing system meets the wind resistance and wafer intrusion performance standards. Aesthetics (appearance) are not a consideration with respect io workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code should be addressed as part of the agreement between the owner and the contractor. /C 2. Renailing wood decks; When replacing roofing, the existing wood roof deck may have to be renailed in accordance with current provisions of Chapter 16 (High -Velocity Hurricane Zones) Of the Florida Building Code, Building. (The roof deck is usually concealed prior to Removing the nn�existing roof system.) X 1Le 3_ Common roofs: Common roofs are those which have no visible delineation between neighboring units (ie., townhouses, condominiums, etc.)_ In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. A c)07.- and/or Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish io maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining ibis appearance. 5. Ponding water. The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in tow -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. kb. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a buildup of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapters 16 and 16 herein and the Florida Building Code, Plumbing. k 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida -licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's/Agent's S.onal_ge Date Contractor's Signature. Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Master Permit No. 1 ‘161-4 —00 (O Process No. Contractor's Name 4C vel / �`n5 s�'�✓;crs i'��. Job Address ❑ Low Slope ❑ Asphaltic Shingles ROOF CATEGORY Mechanically Fastened Tile 0 Mortar/Adhesive Set Tile 0 Metal Panel/Shingles 0 Wood Shingles/Shakes 0 Prescriptive BUR -RAS 150 ROOF TYPE I9 New Roof 0 Reroofing 0 Recovering 0 Repair 0 Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) SteepSlopedRoof Area (SF) Total (SF) L Zq 112.4i 3 SECTION B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. '; 'A' - 'ICA EMI ■■■■ ■■■■ Urn MUM ROOM ■■■■ ■■■■ ■EI ■ ■ ■ kX aft AWS !IV!:i 1 I , &. A6,1c mew I. HIGH -VELOCITY HURRICANE ZONES Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) Roof System Manufacturer: J c Ic "zoo f -T,7-6 Product Approval Number: 1 / — 032 l • d 3 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: -47 P2: No. P3: toc) . (o Maximum Design Pressure //, . Product Approval Specific System: Method of tile attachment: a IDD 4-5. A '' Steep Sloped Roof System Description Deck Type: C Dx ype Underlayment: Roof Slope: :12 Ridge Ventilation? A/(4 Mean Roof Height: Insulation: 11- A- ► 3)%5 Lapfrd y''6. C IAAF Fire Ranier: 1 Fastener Type & Spacing: i awy. a 5. v .is -a i0 7;--7V5_5- 1(;;," 7 5 - 1(;;," d. 4 rb /4/'5 2.11-47A,5 i z " F, •e 0 Adhesive Type: ype Cap Sheet: oof Covering: I �`*y )*C C'40/5k4no Type & Size Drip dge: 1Z"" Nur`Ia) (.7_, JJ 2.& r )y c 2010 FLORIDA BUILDING CODE — RESIDENTIAL 44.23 Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Com for Mr with the values from Mf. If the Mr values are greater t values, for each are. : the roof, then the tile attach e the values or equal to the Mr method is acceptable. Method 1 "Momen : _ _ . Tile Calculations Per RAS 127" (P1: x h =9: = Product Approval Mr (P2: x x, _ - Mg: = Mr2 Product Approval Mt (P3: x A _ ) - M9: = Mr3 • . , ct Approval M, Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From Table Below 31. le Product Approval Mt 7 L Mean Roof Height -* Roof Slope 4. 2:12 3:12 4:12 6:12 7:12 M, Required Moment Resistance* 15' 34.4 32.2 30.4 28.4 26.4 24.4 20' 36.5 34.4 32.2 30.1 28.0 25.9 25' 38.2 36.0 1 33.8 I 1 29.4 1 27.1 1 30' 39.7 37.4 35.1 32.8 30.5 28.2 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. 40' 42.2 39.8 37.3 34.9 32.4 30.0 For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment m:thod is acceptable. Method ' ptift Based Tile Calculations Per RAS 127" (P,: x 1: = x w:= - W: x cos 0: - = F„ Product Approval F' (P2: x 1: = x w:= ) x cos a - = F2 Product Approval F' (P3: x 1: = x w:= ) - W: x cos 0: -7 F, Product Approval F' Description I 1 1 Design Pressure Mean Roof Height Roof Slope Aerodynamic Multiplier Restoring Moment due to Gravity I Attachment Resistance 1 Required Moment Resistance Minimum Attachment Resistance 1 Required Uplift Resistabe 1 I Average Tile Weight 1 W Tile = length Dimensions w = width Where to Obt• • ormation Symbol P1 or P2 or P3 H M, M, F' F, Where to find RA 27 Table 1 or by an et ineering analysis prepared by PE based on ASCE 7 b Site Job Site Product Approval Product Approval IProduct Approval 1I Calculated I Product Approval 1 Calculated 1 Product Approval Product Approval I All calculations must be submitted to the Building Official at the lime of permit application. DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www. miamidad e. gov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. „ktrio' MIAMI•DADE COUNTY APPROVED NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 1 of 8 ROOFING COMPONENT APPROVAL Cate>rorv: Sub-Catetwrv: Material: Roofing Underlayment SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1&#2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Surface Printing) Manufacturing Location #1 & #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 MIAMI•DADE COUNTY APPROVED Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Roll: 65' x 3'33/8" Or 65' x 3' 60 mils thick Roll: 32' 10" x 3'33/8" 100 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32' 10" x 3'33/8" 130 mils thick Roll: 61' x 3'3-34" 60 mils thick Roll: 61' x 3'3-3/8" 60 mils thick Test Specification TAS 103 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 Product Description A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. A fine granular/sand top surface self -adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A rubberized asphalt self -adhering, glass- fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self -adhering, glass- fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt self -adhering, glass- fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PRODUCTS DESCRIPTION: Product Polystick TU Max Manufacturing Location #2 Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick MANUFACTURING PLANTS: 1.Hazelton, PA 2.Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. MIAMI-DADE COUNTY ►_III ;ROD 411� Test Specification TAS 103 and ASTM D 1970 Test Identifier 11756.04.01-1 11756.08.01-1 02202.08.05 P5110.08.07 P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390. 08.12-1 P40390.08.12-2 P40390.10.12 PRI01111 PUSA-005-02-01 PUSA-018-02-01 PUSA-035-02-01 PUSA-033-02-01 PUSA-055-02-02 PUSA-083-02-01 PUSA-089-02-01 JX20H7A RX 14E8A DX23D8B DX23D8A Product Description A rubberized asphalt self -adhering, polyester reinforced waterproofing membrane. Designed as a a roof tile underlayment. Test Name/Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103/ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103/ASTM D4798 & G155 TAS 110/ASTM D4798 & D1970 TAS 103 & TAS 110 ASTM D 1623 ASTM D 1970 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 09/01/11 10/19/11 08/06/12 08/07/12 10/03/12 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self -adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-'h" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. MIAMI-DADE COUNTY APPROVED NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) MTS IR -Xe TU TU Plus TU P Tile Pro Dual Pro TU Max Winter Haven, FL. 180 180 180 180 180 180 180 90 Hazelton, PA. N/A 30 30 180 N/A N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, TU Polystick TU Plus, TU P, Tile Max Pro Flat Tile Prohibited without battens Profiled Tile Prohibited without battens 5:12 No limitation No limitation Prohibited No limitation No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. MIAMI -ADE COUNTY APPROVED NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. Roofing Tiles (6 Max Per Stack) 12 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. MIAMI•DADE COUNTY APPROVED NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. MIAMI.DADE COUNTY APPROVED NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE MIAMI -ADE COUNTY APPROVED NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 8 of 8 MIAMI•DiADE mikai BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.eov/buildine/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Capistrano Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #07-1018.09 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMIOADE COUNTY APPROVED NOA No.:11-0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This approves a new roofing system using "Capistrano Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Applicant Dimensions Capistrano Concrete L = 17" Tile W = 12 1/4" Thickness ='/2" Trim Pieces I = varies w = varies varying thickness MIAMIOADE COUNTY APPROVED Test Specifications Product Description TAS 112 High profile concrete roof tile. For direct deck or battened nail -on applications. TAS 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. NOA No.:11-0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 2 of 7 2.1 EVIDENCE SUBMITTED: Test Agency PRI Asphalt Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Celotex Corporation Testing Services Walker Engineering, Inc. MIAMI OADE COUNTY APPROVED Test Identifier ERPF -001-02-02 7161-03 Appendix III Letter Dated Aug. 1, 1994 P09647-01 P0402 94-083 94-084 25-7094-(3, 6 & 9) 25-7120-(1 & 2) 25-7183-(3 & 4) 25-7214-(3, 4, &7) 25-7804-4 520111-3 520191-2-1 Calculations Test Name/Renort TAS -112 Static Uplift Testing TAS 102 & 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 Aerodynamic Multiplier Date Aug. 2006 Dec. 1991 Aug. 1994 Aug. 1994 Sept. 1993 April 1994 May 1994 Oct. 1994 Nov. 1994 Feb. 1995 March, 1995 Sep. 1996 Dec. 1998 March 1999 Sep. 2006 NOA No.:11-0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 3 of 7 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Capistrano Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Capistrano Concrete Tile Tile Profile Capistrano Concrete Tile Tile Profile Capistrano Battens Concrete Tile 6.68 Weight -W (Ibf) Table 2: 10 Length -I (ft) 1.417 Aerodynamic Multipliers - A (ft3) A (fta) Batten Application 0.300 Width -w (ft) 1.04 A (ft) Direct Deck Application 0.277 Table 3: Restoring Moments due to Gravity - Ma (ft-Ibf) 3":12" 4":12" 5":12" 6":12" MIAMI :ADE COUNTY maim Direct Battens Deck 6.99 6.57 Direct Battens Deck 6.88 6.44 Direct Battens Deck 6.73 6.28 Greater than 7":12" Direct Battens Direct Deck Deck 6.56 6.10 6.38 NOA No.:11-0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 4 of 7 Tile Profile Capistrano Concrete Tile Table 4: Attachment Resistance Expressed as a Moment - M1 (ft-Ibf) for Nail -On Systems Fastener Type Direct Deck Direct Deck (min 15132" plywood) (min. 19132" plywood) 2-10d Ring Shank Nails 1-10d Smooth or Screw Shank Nail 2-10d Smooth or Screw Shank Nails 1 #8 Screw 2 #8 Screw 1-10d Smooth or Screw Shank Nail (Field Clip) 1-10d Smooth or Screw Shank Nail (Eave Clip) 2-10d Smooth or Screw Shank Nails (Field Clip) 2-10d Smooth or Screw Shank Nails (Eave Clip) 28.6 5.1 41.2 6.8 6.9 9.2 20.7 43.2 23.1 20.7 43.2 23.1 29.3 29.3 27.6 27.6 38.1 38.1 Battens 19.4 2.8 7.3 18.1 29.8 19.0 24.0 38.6 41.8 2-10d Ring Shank Nails' 1 33.1 48.1 1 45.2 1. Installation with a 4" tile headlap and fasterners are located a min. of 2W from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Tile Application Profile Capistrano Concrete Tile Adhesive 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 10.7 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Minimum Attachment Resistance 29.3' Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Tile Application Profile Capistrano Concrete Tile Polyfoam PolyProTM Polyfoam PolyProTM 3 Large paddy placement of 63grams of PolyProTo. 4 Medium paddy placement of 24grams of PolyProTM. Minimum Attachment Resistance 66.5' 38.7° Table 7: Attachment Resistance Expressed as a Moment for Mortar Set Systems Tile Application Mortar Set° Tile Profile Capistrano Concrete Tile 5 Tile-Tite Roof Tile Mortar. MIAMI DADE COUNTY APPROVED Mf (ft-Ibf) Attachment Resistance 24.5 NOA No.:11-0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 5 of 7 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". FLORIDA CAPISTRANO CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. MIAMtDADE COUNTY APPROVED NOA No.:11-0321.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 6 of 7 PROFILE DRAWING iN*ILLJ1110L1 CAPISTRANO CONCRETE ROOF TILE END OF THIS ACCEPTANCE MIAMI.DADE COUNTY APPROVED NOA No.:11-032I.03 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 7 of 7 CITY OF PARKLAND BUILDING DEPARTMENT 954-753-5447 Date Received: 4/1/14 Permit Number: BLDG1404-0010 Lot: 10 Block: J Subdivision: HERON BAY NORTH PLAT 3 Job Address: 11496 NW 81 PL Work Description: 10/J OSPREY LAKES Contractor: WCI COMMUNITIES Phone: 2394443433 LLC DEPARTMENT Date Denied Date Approved Initials ZONING LANDSCAPING ENGINEERING FIRE STRUCTURAL L}.- a- -(4 C ELECTRICAL PLUMBING 1 MECHANICAL