Loading...
HomeMy WebLinkAboutBLDG1403-0024-EngineeringBroward County Board of Rules and Appeals One North University Drive, 3500-B Fort Lauderdale, Florida 3331-4 Effective: March I 5, 20 12 Telephone: 95-4.765.-4500 Facsimile: 95-4.165.-450-4 FORM FOR "SPECIAL BUILDING INSPECTOR" SECTION 110.10-BROWARD COUNTY ADMINISTRATIVE CODE ANP THE 2010 FLORIDA BUILQING CODE NOTICE TO PROPERTY OWNER: You are hereby directed in accordance with Section 110.10.1 of the Broward County Administrative Code and the Florida Building Code to retain a Special Structural Inspector (A Florida Registered Architect or Ucensed Engineer) to perform the following mandatory or discretionary inspections, as oudined in Sections 110.10, 1822, 212U.4, 2218.2, R~7.5.4, 2223.11.1, 1927.12.1, 1927.12.2, R~S.9.12.1, R~5.9.12.2, R4408.5.2 & R4408.10.11 of the Florida Building Code and submit progress reports, inspections reports, and a Certificate of Compliance to the Building Official as per Sections II 0.1 0.6 and I I 0.1 0.7 of the Florida Building Code. Note: The Building Official determines which discretionary inspections are to be delegated. DATE: \ { r~ /J4 IDENTIACATION, CONTROL OR BUILDING PERMIT# ________ _ PROJECT NAME: Heron Bay North -Osgrey Lakes Plat 3 -Lot 3F JOBAooRESS 'f SB<.o Nw "19 Ma.,r-..or , Pa.rr laf\d ZIP-"'-33""'o-'-"76:......_ ___ _ LEGAL DESCRIPTION: -------------------------------------------------R)UO# _____________ _ A. MANDATORY INSPECTIONS TYPE BY CODE: I) Precast Concrete Units-Section 1927.121, R-4405.9.121, II 0.1 0.2 '----·-···--·····-·---·---·-·····-··-·---------------··------·Yes 0 No 181 2) Precast Concrete Units-Section 1927.122, R-4405.9.122, II 0.1 0.21----··-···-·-·····-·--·-·--·-··-··----------·--··--··--·-----·-Yes 0 No 181 3) Reinforced Unit Masonry-Section 21222-4, R-44075.-4, 110.10.22 (per ACI 530.1-05-l..evel B Quality Assurance)* *unless noted otherwise on plan-·-·······-··-····-··-·-·-·····-········-··---·-·-·-·-········-····--·-···--···-···--···-------·--··------·---·----.. _yes 0 No 181 -4) Connections -Section 2218.2, I I 0.1 0.23 ---·--·-··-·-----··-·-·----·---·--···---·-······--·---·-·-··-·-·-------···-····-·-···-·---·-·-··-·--···-··Yes 0No 181 5) Metal System Buadings-Section 2223.11.1, 110.10.2-4. R+408.10.11 ·--··-···-····-·-·-··-····-····-··-·-······----·---·---·----·---·---·-·-··-·····Yes 0 No 181 B. DISCRETIONARY INSPECTION TYPE BY BUILDING OFFICIAL: I) Building Structures or pan thereof ol Unusual Size, Height, Design or Method of Construction and Critical Strucwral Connections-Section II 0.1 0.1.1 -·····-···--·---·-··--·-··-·-·-···-···-··-·········---·--·----·--··--·-------·----------··· Yes 0 No 181 2) Windows. Glass Doors and Curtain Walls on buildings over two (2) stories-Section 110.1 0.1.1 -·-·-···--···--·-------·-----------····Yes 0 No 181 3) Pile Driving Only-Sections 1822, R-4-404.13, II 0.1 0.1.1.·---···--·---···--·-········-·····--·-····-····------··----·------·-------·---·---··-···· Yes 0 No 181 -4) Precast Concrete Units-Section 1822, R+405. 9.12, I I 0.1 0.21 ··----·-·-·····--···-·-···--·-·····-·-··-······-··--------·-----·-·---··--·········--····-·Yes 0 No 181 5) Reinforced Unit masonry-Sections 21222-4, R-4407.5.-4, 110.10.22 .. -·-··-····-···-····-··----··-··-···--·-·-·-·-··-·-··-·-··---·----------···Yes 181 No 0 6) Other.·-·-··-·-·-·---·-·-··--···--·-··--··--·······-······--·····-··-····-····---·-·-·-··-·-···-·---·····-·······-·····-·-·····-····-··----·-·····---·--·-··---··-·-·-··--·Yes 0 No 181 C. MANDATORY DOCUMENTATION I) Inspection schedule stating the specific inspection that will be made and at what phase of construction must be submitted with this application. 2) Progress Report/Inspection reports during construction in accordance with Section 110.10.6. 3) Certificate of Compliance must be submitted prior to the scheduling of the final building inspection, Section II 0.1 0.7. Printed Name: Paul Erhardt SPECIAL BUILDING INSPECTOR: 0 Registered Architect and/or 181 Ucensed Engineer Stated Rorida Registration# ---~3 .. 5..,.68,......3 ________ _ ____________________________________________________________ ,Da~ -------------------------- Building Official (or designated representative) ***BE ADVISED THIS DOES NOT PRECLUDE YOU FROM OTHER MANDATORY INSPECTIONS IN THE CODE*** G:\SHARED\Forms\2010 FBC Special Bldg lnsp Form.doc GALE INSULATION S/0 # 401684163/401737298 CERTIFICATE OF INSULATION -INSTALLATION JOB ADDRESS: 11586 NW 79 MANOR PARKLAND, FL LOT 603 OSPREY LAKE STATEMENT OF COMPLIANCE: We, the undersigned, hereby certify that the thermal insulation has been installed in the referenced building in compliance with the Florida Model Energy Efficiency Building Code and the approved plans and specifications, and in accordance with good construction practice. The insulation furnished is of the type, thickness and R-value as set forth below: AREA TYPE THICKNESS R-VALUE MANUFACTURER CEILING AREA FIBERGLASS 12.75"/12" R-38 OWENS CORNING 1sr FLR/NOT BLOW/BATT ACCESSIBLE GARAGE FIBERGLASS 3.5" R-11 OWENS CORNING COMMON WALL BATT EXTERIOR REFLECTIVE .75" R-4.1 FI-FOIL COMPANY MASONRY FOIL WALLS INSULATION CGC1512179 5,2014 INSULATION CONTRACTOR'S SIGNATURE: BUILDER: WCI COMMUNITIES: SIGNATURE: --------------- 1 PERSONALLY KNOW THE AFFIANT, PAMELA FENTON. Sworn to and subscribed before me this. zs-day of ~ I 2014 Notary Public, State of Florida~...-..--" c , ~ -~ l~~-:f.{f~\ MARLIS C SMITH-DOBLER t•\~)•j MY COMMISSION #FF112303 '•{;;;,:c;,,;_~Y EXPIRES May 9, 2018 (40;j·~153 FloridaNotaryService.com SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach LETTER OF INTENT FOR SPECIAL INSPECTOR FOR TRUSS ERECTION January 13, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North -Osprey Lakes Plat 3 -Lot 3F 11586 NW 79 Manor, Parkland, FL 33076 Building Department: Please be advised that we, Specialty Engineering Consultants; Inc, have been retained by WCI Communities, LLC to supervise the erection of trusses with bottom chord in excess of 35' or height greater than 6' in accordance With Section 2319.17.2.4 of the Florida Building Code for the referenced project. T~s letter of intent is to be followed up by an Inspection Certification for truss erection which attests to the above. Respectfully submitted, Specialty Engineering Consultants, Inc. ---- Partner State of Florida: Registered Professional Engineer: Registered Special Inspector: #0035683 #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULT ANTS, Inc. Dade • Broward • Palm Beach STATEMENT OF INTENT AND SCOPE OF WORK FOR ENGINEERED UNIT MASONRY January 13, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North -Osprey Lakes Plat 3 -Lot 3F 11586 NW 79 Manor, Parkland, FL 33076 Building Department: We, Specialty Engineering Consultants; Inc, shall personally inspect the entire "Engineered Unit Masonry" system for this building, including but not limited to the following: 1. Masonry units, mortar, grout and reinforcing steel met specifications. 2. Dowels properly placed with adequate spacing. 3. Steel column ties in columns, pilasters and beam elevation transitions properly placed, tapped and tied. 4. Masonry field work: head and bed joints, horizontal joint reinforcing installed correctly, cells free of excessive mortar fins, walls level and plumb tolerances. 5. Monitor grout placement, verify grout slump, proper consolidation of grout and proper low or high lift grouting procedures were followed. 6. Correct embedment of reinforcing steel, bolts, ties, etc. 7. Compliance with ACI 530-08/ASCE 5-08 and commentaries, approved plans and 2010 FBC. This letter of intent is to be followed up by an Inspection Certification for Unit Masonry which attests to the above. '" State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 itlh {JJ,; l\.l~; .. oo2~PECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR UNIT MASONRY June 9, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North -Osprey Lakes Plat 3 -Lot 3F 11586 NW 79 Manor, Parkland, FL Permit#: 1403-0024 Building Department: We have personally inspected the complete "engineered unit masonry" system for this building. This inspection includes all of its components such as; steel placement; horizontal joint reinforcement; vertical and horizontal reinforcing steel for the concrete masonry units and all associated tie beams, tie columns, etc. In addition, we have monitored and verified grout placement. We find that all aspects of this system conform to the approved plans and the Florida Building Code, sections 2122.4 and BCAC 105.10.2.2. LeBlanc, PE Partner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULT ANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR UNIT MASONRY June 9, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North -Osprey Lakes Plat 3 -Lot 3F 11586 NW 79 Manor, Parkland, FL Permit #: 1403-0024 Building Department: We have personally inspected the complete "engineered unit masonry" system for this building. This inspection includes all of its components such as; steel placement; horizontal joint reinforcement; vertical and horizontal reinforcing steel for the concrete masonry units and all associated tie beams, tie columns, etc. In addition, we have monitored and verified grout placement. We find that all aspects of this system conform to the approved plans and the Florida Building Code, sections 2122.4 and BCAC 105.10.2.2. State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 ·- SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR TRUSS ERECTION June 9, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North -Osprey Lakes Plat 3 -Lot 3F 11586 NW 79 Manor, Parkland, FL Permit#: 1403-0024 Building Department: Please be advised that we, Specialty Engineering Consultants; Inc, monitored the erection of trusses with bottom chord in excess of 35' or height greater than 6' in accordance with Section 2319.17.2.4 of the Florida Building Code for the referenced project. We find that all aspects of this system conform to the approved plans and the Florida Building Code. submitted, ngineering Consultants, Inc. State of Florida: Registered Professional Engineer #0035683 Registered Special Inspector #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 -- SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR TRUSS ENGINEERING June 9, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North -Osprey Lakes Plat 3 -Lot 3F 11586 NW 79 Manor, Parkland, FL Permit#: 1403-0024 Building Department: We have personally inspected the truss system on the above referenced property and find the trusses are erected properly and without any apparent damage. We have checked all aspects of this truss system -roof trusses and floor trusses, where used -including, but not limited to the following components. 1. Proper size, grade and species of lumber used in the assembly of each truss per engineering. 2. Nail-on position or press-an plates checked for proper size and position per engineering. 3. Trusses and girders checked for proper anchorage for both gravity loads and uplift loads. 4. Lateral bracing applied to truss members per engineering and building code. 5. All other bracing to resist lateral forces, in addition to that specified by truss engineering, has been applied as required by the Architect-of-Record's approved plans. This includes the addition of shear walls, let-in wall bracing, floor system bracing, proper positioning of sheathing, etc. We have also inspected any repaired and/or mod.ified trusses. and have ascertained that they have been corrected in accordance with: "Sealed" repair engineering supplied by the truss engineer. All engineering sheets for repaired and/or modified trusses are included herewith. Respectively submitted, SPECIA NGINEERING CONSUL TA State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULT ANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR TRUSS ENGINEERING June 9, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North -Osprey Lakes Plat 3-Lot 3F 11586 NW 79 Manor, Parkland, FL Permit#: 1403-0024 Building Department: We have personally inspected the truss system on the above referenced property and find the trusses are erected properly and without any apparent damage. We have checked all aspects of this truss system -roof trusses and floor trusses, where used -including, but not limited to the following components. 1. Proper size, grade and species of lumber used in the assembly of each truss per engineering. 2. Nail-on position or press-on plates checked for proper size and position per engineering. 3. Trusses and girders checked for proper anchorage for both gravity loads and uplift loads. 4. Lateral bracing applied to truss members per engineering and building code. 5. All other bracing to resist lateral forces, in addition to that specified by truss engineering, has been applied as required by the Architect-of-Record's approved plans. This includes the addition of shear walls, let-in wall bracing, floor system bracing, proper positioning of sheathing, etc. We have also inspected any repaireci and/or mociifieci trusses and have ascertained that they have been corrected in accordance with: "Sealed" repair engineering supplied by the truss engineer. All engineering sheets for repaired and/or modified trusses are included herewith. Respectively submitted, SPECIA NGINEERING CONSULTA C. State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 ~t>£o, 1\./03-0DZ.j SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR TRUSS ERECTION June 9, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North -Osprey Lakes Plat 3 -Lot 3F 11586 NW 79 Manor, Parkland, FL Permit#: 1403-0024 Building Department: Please be advised that we, Specialty Engineering Consultants; Inc, monitored the erection of trusses with bottom chord in excess of 35' or height greater than 6' in accordance with Section 2319.17.2.4 of the Florida Building Code for the referenced project. We find that all aspects of this system conform to the approved plans and the Florida Building Code. submitted, ngineering Consultants, Inc. ------- State of Florida: Registered Professional Engineer #0035683 Registered Special Inspector #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach THRESHOYJ(SPECIAL I SP~CTION REPORT PROJECT: (j;J s ',U CONTRACTOR: INSPECTION TYPE: ';) PROJECT LOCATION:~ MIZ{~ MEMBERS I AREAS INSPECTED: DISPOSITION I RESULTS: GENERAL NOTES: Respectfully submitted, Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State o~ Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 Form001 ThresholdSpec,allnspec GG 01/04 DAY: DATE: TRACKING#: PERFORMED BY: DISTRIBUTION COPY: 1599 S. W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 ·'· /' SPECIALTY ENGINEERING CONSULTANTS, Inc. I Dade • Broward • Palm Beach THRESHOLD/SPECIAL INSPECTION REPORT PROJECT: ~~f:= CLIENT: . CONTRACTOR: TRACKIN . .::.:G~#=~----!~9d~-------- PERFORMED BY: {~ MEMBERS I AREAS INSPECTED: DISPOSITION I RESULTS: GENERAL NOTES: -·--------------------------------------------------------------------------------- Respectfully submitted, Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 DISTRIBUTION COPY: Form001 ThresholdSpec,allnspec GG 01/04 1599 s. w. 30th 'l\venue, Suite #20 • Boynton Beach, FL 33426 • Offict 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach THRESHOL~PECIAL IN$PECTION REPORT :::~~T= u ff1j ctt;u CONTRACTOR: MEMBERS I AREAS INSPECTED: DISPOSITION I RESULTS: GENERAL NOTES: Respectfully submitted, Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 Form001 ThresholdSpeciallnspec GG 01/04 DAY: DATE: PERMIT No. TRACKING#: PERFORMED BY: DISTRIBUTION COPY: 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach THRESHOLD/SPECIAL INSPECTION REPORT PROJECT: ~ fn t: CUEN~ · CONTRACTOR: INSPECTION TYPE: ~ DISPOSITION I RESULTS: GENERAL NOTES: Respectfully submitted, Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 Form001 ThresholdSpeciallnspec GG 01/04 DAY: DATE: PERMIT No. TRACKING#: PERFORMED BY: N DISTRIBUTION COPY: 1599 S. W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 PROJECT: CLIENT: CONTRACTOR: INSPECTION TYPE: PROJECT LOCATION: MEMBERS I AREAS INSPECTED: DISPOSITION I RESULTS: GENERAL NOTES: Respectfully submitted, Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 Form001 ThresholdSpec•allnspec GG 01/04 -----~--- SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach DAY: DATE: PERMIT No. TRACKING#: PERFORMED BY: DISTRIBUTION COPY: 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 • ........... SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach /SPECIAL INSPECTION REPORT PROJECT: CLIENT: CONTRACTOR: DISPOSITION I RESULTS: GENERAL NOTES: Respectfully submitted, Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State o! Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 Form001 ThresholdSpec1allnspec GG 01/04 3r I DISTRIBUTION COPY: 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach THRESHOL~PECIAL INSPECTION REPORT PROJECT: ~ CLIENT: CONTRACTOR: MEMBERS I AREAS INSPECTED: DISPOSITION I RESULTS: GENERAL NOTES: Respectfully submitted, Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State o~ Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 Form001 ThresholdSpeciallnspec GG 01/04 DAY: TRACKING#: PERFORMED BY: ' I <X(; ,A J u..J 71 11 ~,~._ {I DISTRIBUTION COPY: 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542