HomeMy WebLinkAboutBLDG1403-0024-Energy CalculationsFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida-Bepartment of Business and Professional Regulation -Residential Performance Method
~
Project Name:
Street:
City, State, Zip:
Owner:
Design Location:
Osprey-HIBISC3 r
Par1dand , FL ,
WCI Communities, LLC
FL, Fort Lauderdale
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft")
Conditioned floor area below grade (ft")
7. Windows(476.2 sqft.) Description
a. U-Factor: Dbl, U=0.60
SHGC: SHGC=0.31
b. U-Factor:
SHGC:
c. U-Factor:
SHGC:
Dbl, U=0.68
SHGC=0.29
Dbl, U=0.38
SHGC=0.31
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
Single-family
4
Yes
2731
0
Area
358.84 ft2
72.00 ft2
24.00 ft2
21.36 ft 2
6.775 ft.
0.304
8. Floor Types (2731.0 sqft.) Insulation
a. Slab-On-Grade Edge Insulation R=O.O
b. N/A R=
• c. N/A R=
Area
2731.00 ft2
ft2
ft2
Builder Name: WCI Communities
Permit Office: Parkland
Permit Number:
Jurisdiction: 163100
9. Wall Types (2819.5 sqft.)
a. Concrete Block -lnt lnsul, Exterior
b. Frame-Steel, Adjacent
c. N/A
d. N/A
10. Ceiling Types (2731.0 sqft.)
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret Attic, AH: AC1
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Natural Gas Tankless
b. Conservation features
None
15. Credits
Glass/Floor Area: 0.174 Total Proposed Modified Loads: 48.02
Total Standard Reference Loads: 73.48
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code. OSCAR L · ~;L:~signedbyOSCARL
•. DN: cn=OSCAR L CALWA. PREPARED BY: . :0 ENG!NEEREDAIR!!C 011
DATE: CALLEJA ·:~~~rc@engineeredairlk.c
· · Date: 2013.06.04 18:33:01 -04'00'
I hereby certify that this building, as designed, is in compliance
with the Florid* --... OWNE~G . ~ ~~c\l U
DATE: \ \ <
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
Insulation Area
R=4.1 2602.80 ft2
R=11.0 216.70 ft2
R= ft2
R= ft2
Insulation Area
R=38.0 2731.00 ft2
R= ft2
R= ft2
R ft2
6 300
kBtu/hr Efficiency
45.5 SEER:14.00
kBtu/hr Efficiency
33.0 COP:1.00
Cap: 1 gallons
EF: 0.820
Pstat
PASS
-Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with 403.2.2.1.1.
-Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
6/4/2013 5:01 PM EnergyGauge® USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of6
PROJECT
Title: Osprey-HIBISCUS Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2731 Lot#
Owner: WCI Communities, LLC Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes Plat Book:
Builder Name: WCI Communities Rotate Angle: 315 Street:
Permit Office: Parkland Cross Ventilation: County: Broward
Jurisdiction: 163100 VI/hole House Fan: City, State, Zip: Parkland,
Family Type: Single-family FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ IECC Design Temp lnt Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
--FL, Fort Lauderdale FL_FORT_LAUDERDALE 1 43 91 70 75 321.5 60 Low
BLOCKS
Number Name Area Volume
1 Block1 2731 27634.6
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms lnfiiiD Finished Cooled Heated
1 AC1 2731 27634.6 Yes 5 4 1 Yes Yes Yes
FLOORS
v # Floor Type Space Perimeter R-Value Area Tile Wood Carpet
--1 Slab-On-Grade Edge lnsulatio AC1 280ft 0 2731 ff --1 0 0
ROOF
/ Roof Gable Roof Solar SA Em itt Em itt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested lnsul. (deg)
--1 Hip Barrel tile 2958 ft2 Off Medium 0.75 No 0.9 No 0 22.6
ATTIC
/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC
1 Full attic Vented 300 2731 ff N N --
CEILING
v # Ceiling Type Space R-Value Area Framing Frac Truss Type
--1 Under Attic (Vented) AC1 38 2731 ff 0.11 Wood
6/4/2013 5:01 PM EnergyGauge® USA-FlaRes201 0 Section 405.4.1 Compliant Software Page 2 of6
WALLS
Vtt nmt
Adjacent Space _ Cavity Width F~ei~t Sheathing Framing Solar Below _ To WaiiTvn .. R-V"h·,., 1=1 In ArF>" R-"''"" f:r"rlin;:; Ahc:nr r::r"n.,ot..
1 NE=>N Exterior --Concrete Block -lnt lnsui AC1 4.1 8.5 :J 12 0 102.0 ft2 0 0 0.5 0
2 NE=>N Exterior --Concrete Block -lnt lnsul AC1 4.1 12.7 0 10 0 127.0 ft 2 0 0 0.5 0
3 --NW=>W Exterior Concrete Block-lnt lnsul AC1 4.1 12.67 0 10 0 126.7 ft2 0 0 0.5 0
4 SE=>E Exterior --Concrete Block -lnt lnsul AC1 4.1 14.2 0 10 0 142.0 ft2 0 0 0.5 0
5 SE=>E Exterior --Concrete Block -lnt lnsul AC1 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0
6 SE=>E Exterior --Concrete Block -lnt lnsul AC1 4.1 13 0 10 0 130.0 ft 2 0 0 0.5 0
7 SE=>E Exterior --Concrete Block-lnt lnsul AC1 4.1 15 0 10 0 150.0 ft 2 0 0 0.5 0
8 W=>SW Exterior Concrete Block-lnt lnsul AC1 4.1 4 0 10 0 40.0 ft2 0 0 0.5 0 --
9 NW=>W Exterior Concrete Block-lnt lnsul AC1 4.1 4.6 0 10 0 46.0 ft2 0 0 0.5 0 --
10 SW=>S Exterior Concrete Block -lnt lnsul AC1 4.1 2.5 0 10 0 25.0 ft2 0 0 0.5 0 --
11 SW=>S Exterior Concrete Block -lnt lnsul AC1 4.1 16 0 10 0 160.0 ft2 0 0 0.5 0 --
12 SE=>E Exterior Concrete Block -lnt lnsul AC1 4.1 17 0 10 0 170.0 ft 2 0 0 0.5 0 --
13 NW=>W Exterior Concrete Block -lnt lnsul AC1 4.1 13 0 10 0 130.0 ft 2 0 0 0.5 0 --
14 SW=>S Exterior Concrete Block -lnt lnsul AC1 4.1 12.4 0 11.3 0 140.1 ft 2 0 0 0.5 0 --
15 NE=>N Exterior Concrete Block -lnt lnsul AC1 4.1 5 0 10 0 50.0 ft2 0 0 0.5 0 --
16 SE=>E Exterior Concrete Block -lnt lnsul AC1 4.1 12 0 10 0 120.0 ft 2 0 0 0.5 0 --
17 NE=>N Garage Frame-Steel AC1 11 6.67 0 10 0 66.7 ft2 0 0.26 0.5 0 --
18 NW=>W Exterior Concrete Block -lnt lnsul AC1 4.1 6.1 0 10 0 61.0 ft2 0 0 0.5 0 --
19 NE=>N Garage Frame-Steel AC1 11 15 0 10 0 150.0 ft2 0 0.26 0.5 0 --
20 NW=>W Exterior Concrete Block-lnt lnsul AC1 4.1 14.5 0 10 0 145.0 ft 2 0 0 0.5 0 --
21 SW=>S Exterior Concrete Block -lnt lnsul AC1 4.1 8 0 10 0 80.0 ft2 0 0 0.5 0 --
;--22 W=>SW Exterior Concrete Block-lnt lnsul AC1 4.1 5 0 10 0 50.0 ft2 0 0 0.5 0
23 S=>SE Exterior Concrete Block -lnt lnsul AC1 4.1 5 0 10 0 50.0 ft2 0 0 0.5 0 --
24 NW=>W Exterior Concrete Block -lnt lnsul AC1 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 --
25 SE=>E Exterior Concrete Block -lnt lnsul AC1 4.1 14.5 0 10 0 145.0 ft 2 0 0 0.5 0 --
26 NW=>W Exterior Concrete Block -lnt lnsul AC1 4.1 10 0 10 0 100.0 ft2 0 0 0.5 0 --
27 NW=>W Exterior Concrete Block -lnt lnsul AC1 4.1 11.3 0 10 0 113.0 ft 2 0 0 0.5 0 --
DOORS
v # Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 NE=>N Insulated AC1 None .6 3 8 24 ft2 --
2 NE=>N Insulated AC1 None .6 2.8 8 22.6 ft 2 --
WINDOWS
Orientation shown is the entered orientation(=>) chanQed to Worst Case.
/ Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation lnt Shade Screening
1 NE=>N 1 Metal Low-E Double Yes 0.38 0.31 24.0 ft2 6ft 0 in 0.2 ft 0 in None None --
2 NE=>N 2 Metal Low-E Double Yes 0.6 0.31 47.2 ft2 1.67 ft 0 i 2ft 0 in None None --
--3 SE=>E 5 Metal Low-E Double Yes 0.6 0.31 9.0 ft2 1.67 ft 0 i 2ft 0 in Drapes/blinds None
4 SE=>E 6 Metal Low-E Double Yes 0.6 0.31 33.1 ft2 1.67 ft 0 i 2ft 0 in None None --
5 W=>SW 8 Metal Low-E Double Yes 0.6 0.31 16.2 ft2 12ft0in 1 ft 0 in None None --
6 NW=>W 9 Metal Low-E Double Yes 0.6 0.31 16.2 ft2 3ft 0 in 1 ft 0 in None None --
6/4/2013 5:01 PM EnergyGauge® USA-FlaRes201 0 Section 405.4.1 Compliant Software Page 3 of6
WINDOWS
Orientation shown is the entered orientation (=>l changed to Worst Case.
v Wall Overhang
# Ornt ID Frame Panes NFRC U-F actor-SHGC Area Depth Separatoon lnt Shade Screening
7 --SW=>S 11 Metal Low-E Double Yes 0.6 0.31 32.3 ft2 1.67 ft 0 i 2ft 0 in None None
8 SE=>E 12 Metal --Low-E Double Yes 0.6 0.31 32.3 ft2 1.67ft0i 2 fl 0 in None None
9 NW=>W13 Metal --Low-E Double Yes 0.6 0.31 16.2 ft2 35 fl 0 in 1 fl 0 in None None
10 NW=>W13 Metal --Low-E Double Yes 0.75 0.25 21.4 ft2 35 fl 0 in 1 ft 0 in None None
11 --SW=>S 14 Metal Low-E Double Yes 0.68 0.29 72.0 ft2 14ft 0 in 1 ft 0 in None None
12 --NE=>N 15 Metal Low-E Double Yes 0.6 0.31 23.6 ft2 1.67 fl 0 i 2ft 0 in None None
13 --NW=>W18 Metal Low-E Double Yes 0.6 0.31 11.4 ft2 1.67 fl 0 i 2 fl 0 in None None
14 NW=>W20 Metal --Low-E Double Yes 0.6 0.31 16.2 ft2 1.67 fl 0 i 2ft 0 in Drapes/blinds None
15 SW=>S 21 Metal Low-E Double Yes 0.6 --0.31 33.1 ft2 1.67 fl 0 i 2 fl 0 in Drapes/blinds None
16 W=>SW22 Metal Low-E Double Yes 0.6 --0.31 16.2 ft2 1.67 fl 0 i 2ft 0 in Drapes/blinds None
17 S=>SE 23 Metal Low-E Double Yes 0.6 0.31 16.2 ft2 1.67 fl 0 i 2 fl 0 in Drapes/blinds None --
18 NW=>W24 Metal Low-E Double Yes 0.6 0.31 16.2 ft2 1.67 fl 0 i 2ft 0 in Drapes/blinds None --
19 NW=>W27 Metal Low-E Double Yes 0.6 0.31 23.6 fl2 1.67 fl 0 i 2 fl 0 in Drapes/blinds None --
GARAGE
v # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 492 ft2 492 ft2 64ft 10 fl 1 --
INFILTRATION
# Scope Method SLA CFM50 ELA EqLA ACH ACH50
1 Wholehouse Best Guess .0005 3581.7 196.63 369.8 .345 7.7766
HEATING SYSTEM
v # System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat None COP: 1 33 kBtu/hr 1 sys#1 --
COOLING SYSTEM
v # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
--1 Central Unit Split SEER: 14 45.5 kBtulhr 1850 cfm 0.78 1 sys#1
HOT WATER SYSTEM
v # System Type SubType Location EF Cap Use SetPnt Conserv.ation
--1 Natural Gas Tankless Garage 0.82 1 gal 70 gal 120 deg None
6/4/2013 5:01 PM EnergyGauge® USA-FlaRes201 0 Section 405.4.1 Compliant Software Page 4 of6
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model # Collector Model # Area Volume FEF
r--
None --None ft2
DUCTS
/ --Supply--Return--Air CFM25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 300 ft2 Attic 40 ft2 Default Leakage AC1 (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling HJan HFeb ~Mar WApr [I May rt Jun rt Jul rtAug n~g woct ~Nov HDec Heating Jan Feb Mar ~ May Jun Jul Aug Oct Nov Dec
Venting Jan Feb Mar May Jun Jul Aug Sep Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling \'NO) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating \'Nf)) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
6/4/2013 5:01 PM EnergyGauge® USA-FlaRes201 0 Section 405.4.1 Compliant Software Page 5 of6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional-Regulations
Reside-ntial Whole Building Performance Method
PERMIT#: I ADDRESS:
_ Parkland, FL,
MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S)
Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting !C-rated as meeting ASTM E 283. Windows and
doors= 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat & 403.1 At least one thermostat shall be provided for each separate heating
controls and cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2. 7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to=
R-2 +accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1
& Spas HP shall have the capability of operating at two or more.speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating 403.6 Sizing calculation performed & attached. Minimum effiCiencies per
equipment
Tables 503.2.3. Equipment efficiency verification required. Special
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >1 OkW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
6/4/2013 5:01 PM EnergyGauge® USA-FlaRes201 0 Section 405.4.1 Compliant Software
CHECK
Page 6 of6
ENERGY PERFORMANCE~LEVEL {EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*= 65
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft")
7. Windows**
a. U-Factor:
SHGC:
b. U-Factor:
SHGC:
c. U-Factor:
SHGC:
Description
Dbl, U=0.60
SHGC=0.31
Dbl, U=0.68
SHGC=0.29
Dbl, U=0.38
SHGC=0.31
New (From Plans)
Single-family
4
Yes
2731
Area
358.84 ft 2
72.00 ft 2
24.00 ft 2
d. U-Factor: other (see details) 21.36 ft 2
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
: 8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
6.775 ft.
0.304
Insulation Area
R=O.O 2731.00 ft2
R= ft2
R= ft 2
, Parkland, FL,
9. Wall Types
a. Concrete Block -lnt lnsul, Exterior
b. Frame-Steel, Adjacent
C. N/A
d. NIA
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
C. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: AC1
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Natural Gas
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Insulation Area
R=4.1 2602.80 ft2
R=11.0 216.70 ft2
R= ft2
R= ft2
Insulation Area
R=38.0 2731.00 ft 2
R= ft2
R= ft2
R ft2
6 300
kBtulhr Efficiency
45.5 SEER:14.00
kBtu/hr Efficiency
33.0 COP:1.00
Cap: 1 gallons
EF: 0.82
Pstat
Builder Signat~-\I:J.__ ~\..b<L Date: d \ \~ \ \.1.
Address of New Home: \ ~S~:A ~~':\\\~ City/FL Zip:~~).~~ ~~ ~~ ~ ~~~~~=-~\ oo~~
\ ~~~\....}
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA-FlaRes201 0 Section 405.4.1 Compliant Software
Osprey-HIBISCUS
HVAC Load Calculations
for
WCI Communities, LLC
RHVAC RssiDEN'l1AL
HVACLOADS
Rhvac is an ACCA approved Manual J and Manual D computer program.
Prepared By:
Oscar L. Calleja
Engineered Air, LLC
2520 N Andrews Ave. Ext
Pompano Beach, Fl 33064
954-449-1600
Tuesday, June 04, 2013
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Project Title:
Designed By:
Project Date:
Client Name:
Company Name:
Company Representative:
Company Address:
Company City:
Company Phone:
Company Fax:
Company E-Mail Address:
Company Comment:
Osprey-HIBISC
Oscar L. Calleja
5/30/2013
WCI Communities, LLC
Engineered Air, LLC
Oscar L. Calleja
2520 N Andrews Ave. Ext
Pompano Beach, F1 33064
954-449-1600
954-973-1883
oscarc@engineeredairllc.com
License No. CAC045860
renee
Building Orientation:
Daily Temperature Range:
E. Fort Lauderdale, Florida
Front door faces Northeast
Medium
Latitude: 26 Degrees
Elevation: 10 ft.
Altitude Factor: 1.000
Outdoor Outdoor Outdoor Indoor Indoor
Det: Bulb Wet Bulb Rei. Hum Rei. Hum Det: Bulb
Winter: 46 43.16 n/a n/a 70
Summer: 90.9 78.4 58% 50% 75
Total Building Supply CFM: 1,850
Square ft. of Room Area: 2,731
Volume (ff') of Cond. Space: 28,078
Btuh 26.526
Btuh 84
Btuh 16
Btuh 3.52
Rhvac an approved Manu computer program.
Grains
Difference
n/a
62
MBH
%
%
Tons (Based On Sensible+ Latent)
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\Oscarc\Documents\Eiite Software\Rhvac 9 Projects\WCI-Hibiscus.rh9 Tuesday, June 04, 2013, 6:30PM
WCI-FixGI: Glazing-WCI-Fixed Gl-dbl-low-e, u-value 24 218 0 664 664
0.38, SHGC 0.31
WCI-SH: Glazing-WCI-SH-dbl-low-e, u-value 0.6, SHGC 228.4 3,291 0 6,523 6,523
0.31
WCI-SH: Glazing-WCI-SH-dbl-low-e, light color blinds at 130.4 1,878 0 3,063 3,063
45° with 50% coverage, u-value 0.6, SHGC 0.31
WCI-FrenchD: Glazing-WCI-French Door-dbl-low-e, u-21.4 384 0 628 628
value 0.75, SHGC 0.25
WCI-SiidinfGI: Glazing-WCI-Siiding Gl-dbl-low-e, u-value 72 1 '175 0 1,220 1,220
0.68, SHGC 0.29
11J: Door-Metal-Fiberglass Core 46.6 618 0 591 591
13A-4ocs: Wall-Block, board insulation only, R-4 board 2102.6 7,216 0 4,871 4,871
insulation, open core, siding finish
12B-Obw: Part-Frame, R-11 insulation in 2 x 4 stud 194.1 376 0 282 282
cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 2613.4 2,008 0 2,584 2,584
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl-c: Floor-Slab on grade, No edge insulation, no 280 6,646 0 0 0
insulation below floor, carpet covering, passive, light
_.Q.r1' soil
Subtotals for structure: 23,810 0 20,426 20,426
People: 5 1,400 1 '150 2,550
Equipment: 2,000 4,200 6,200
Lighting: 0 0 0
Ductwork: 0 1,315 6,492 7,807
Infiltration: Winter CFM: 103, Summer CFM: 51 2,716 2,177 900 3,077
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
AED Excursion: 0 0 2,188 2,188
System 1 AC-1 Load Totals: 26,526 6,892 35,356 42,247
%
Tons (Based On Sensible+ Latent) ...................
an approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\Oscarc\Documents\Eiite Software\Rhvac 9 Projects\WCI-Hibiscus.rh9 Tuesday, June 04, 2013, 6:30PM
Cooling
System Type:
Outdoor Model:
Indoor Model:
Tradename:
Outdoor Manufacturer:
AHRI Reference No.:
Nominal Capacity:
Efficiency:
Heating
System Type:
Model:
Capacity:
Efficiency:
Standard Air Conditioner
CA 13NA048****(A,B)
FB4CNF060
13 SEER PURON AC
CARRIER AIR CONDITIONING
4542180
45500
14 SEER
Electric Resistance
10 KW
0
0%
This system's equipment was selected in accordance with ACCA Manual S.
ManualS equipment sizing data: SODB: 90.9F, SOWB: 78.4F, WODB: 46F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen.
gain: 35,356 Btuh, Lat. gain: 6,892 Btuh, Sen. loss: 26,526 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F,
Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 20F, Req. clg. airflow: 1608 CFM, Req. htg. airflow: 1206 CFM
C:\Users\Oscarc\Documents\Eiite Software\Rhvac 9 Projects\WCI-Hibiscus.rh9 Tuesday, June 04, 2013,6:30 PM
All rotation degree values in this report are clockwise with respect to the project's original orientation.
Building orientation as entered (zero degrees rotation): Front door faces Northeast
At least one system with its System Air Type input set to Fixed was changed to Auto during the building rotation. If you
want to change this behavior uncheck the option on the General tab of the Select Reports dialog called "Always use Auto
for System Air Type for Building Rotation Report."
System 1:
Zone 1:
1 Foyer 57
2 Den/Bed #4 161
3 Powder Bath 26
4 Dining 74
5 Kitchen *139
6 Breakfast Nook *112
7 Family Room 313
8 Living Room 198
Zone 2:
9 Bathroom #2 *5
1 0 Bedroom #2 107
11 Laundry 68
12 Bedroom #3 113
13 Hallway & Closet *3
Zone 3:
14 Master Bedroom 347
15 HER WIC *33
16 HIS WIC *5
17 Master Toilet *1
18 Master Bath 91
*Indicates highest CFM of all rotations.
oo
45° goo
135°
180°
225°
270°
315°
East
Southeast
South
Southwest
West
Northwest
North
*Indicates highest value of all rotations.
62
171
26
65
136
74
294
*253
5
143
68
80
3
*362
33
5
1
53
61
169
35
115
136
57
*314
186
5
132
68
85
3
318
*1 ,609
1,516
1,590
1,465
1,510
1,442
1,481
1,461
33
5
1
53
54
154
*44
*133
133
62
296
105
5
89
68
115
3
242
33
5
1
98
71
223
35
98
132
65
265
112
5
137
68
83
3
285
33
5
1
84
*35,390
33,342
34,957
32,227
33,212
31,717
32,562
32,129
C :\Users\Oscarc\Documents\Eiite Software\Rhvac 9 Projects\WCI-Hibiscus.rh9
*94
*253
26
63
133
61
228
131
5
*151
68
79
3
314
33
5
1
53
75
205
26
63
133
82
234
129
5
128
68
105
3
262
33
5
1
94
6,899
6,898
6,892
6,892
6,897
*6,899
6,899
6,894
52 1--6
154 2-7
26 1-4
72 1-7
133 1--7
109 1-7
274 2-8
113 2-7
5 1-4
99 1-8
*73 1-5
*124 1--7
3 1-4
294 2-9
33 1-4
5 1-4
1 1-4
*111 1-7
Tuesday, June 04, 2013, 6:30PM