HomeMy WebLinkAboutBLDG1403-0025-EngineeringBroward County Board of Rules and Appeals One North University Drive, 3500-B Fort Lauderdale, Florida 33324 Effective: March 15, 2012 Telephone: 954.765.4500 Facsimile: 954.765.4504 FORM FOR "SPECIAL BUILDING INSPECTOR" SECTION 110.10 — BROWARD COUNTY ADMINISTRATIVE CODE AND THE 2010 FLORIDA BUILDING CODE NOTICE TO PROPERTY OWNER: You are hereby directed in accordance with Section 110.10.1 of the Broward County Administrative Code and the Florida Building Code to retain a Special Structural Inspector (A Florida Registered Architect or Licensed Engineer) to perform the following mandatory or discretionary inspections, as outlined in Sections 110.10, 1822, 2122.2.4, 2218.2, R4407.5.4, 2223.1 1.1, 1927.12.1, 1927.12.2, R4405.9.12.1, R4405.9.12.2, R44085.2 & R4408.10.11 of the Florida Building Code and submit progress reports, inspections reports, and a Certificate of Compliance to the Building Official as per Sections 110.10.6 and 110.10.7 of the Florida Building Code. Note: The Building Official determines which discretionary inspections are to be delegated. DATE I 1 i / 14 IDENTIFICATION, CONTROL OR BUILDING PERMIT # PROJECT NAME Heron Bav North — Osprey Lakes Plat 3 — Lot 10 %'i JOB ADDRESS unto 9 N W 19 Manor @ P( rk I aft d ZIP 33076 LEGAL DESCRIPTION: FOLIO # A. MANDATORY INSPECTIONS TYPE BY CODE: 1) Precast Concrete Units — Section 1927.121. R4405.9.12. i, 110.10.21_..__..._......_..---_.......__---_._.....-•-.--.......---__.._...----._...._._--•--._.._......_. Yes 0 No 2) Precast Concrete Units — Section 1927.12.2, 84405.9.12.2, 110.10.2.1_._.---.__._..._..__......_.----..._......_.___.__.._.___.___.___.._._--••----._.._._...-. Yes E] No 23 3) Reinforced Unit Masonry — Section 2122.2.4, R4407.5.4, 110.10.2.2 (per ACI 530.1 -05 -Level B Quality Assurance)* *unless noted otherwise on plan_ _..___ __._ _-... _ _---•-•---•--_...._...__-•--- .. Yes 0 No 4) Connections — Section 2218.2, 1 10.10.2.3---_..._---__.__.___.....---••-•---..._._..........-._...... Yes ❑No 5) Metal System Buildings — Section 7771 11 1 1 10.10.2.4, R4408.10.1 I.-........_.............._..._.._........._.........----....._---•--•------.___._.._.___...._.._..... Yes 0 No B. DISCRETIONARY INSPECTION TYPE BY BUILDING OFFICIAL: 1) Building Structures or part thereof of Unusual Size, Height, Design or Method of Construction and Critical Structural Connections— Section 1 10.10.1.1_...__..._.__._..__..-....._...-._._..._...----_........._._.._.__...--••---.._---_----_.....--•__-.__ Yes 0 No 2) Windows, Glass Doors and Curtain Walls on buildings over two (2) stories — Section 1 10.10.1.1................._........___.._.._._.___..._..__._........ Yes 0 No El 3) Pile Driving Only — Sections 1822, R4404.13, 110.10,1.1_ _........ _..... _._..._.......... _................. _________ ..... ___________ .... ___...... ..._.__. Yes 0 No IEJ 4) Precast Concrete Units — Section 1822, R4405.9.12, 110.10.21.._._.._._._.._..._..._._...__._.._...._.._._..._.._._-.-__.________.-_._.._.._.._._.....___.._.Yes [] No El 5) Reinforced Unit masonry — Sections 2122.2.4, R4407.5.4, 110.10.12.._...-.__.__._.... ________ Yes J8 No ❑ 6) Other . -.-•_- Yes ❑ No C. MANDATORY DOCUMENTATION 1) Inspection schedule stating the specific inspection that will be made and at what phase of construction must be submitted with this application. 2) Progress Report/Inspection reports during construction in accordance with Section 110.10.6. 3) Certificate of Compliance must be submitted prior to the scheduling of the final building inspection, Section 110.10.7. Owner's Signature: Printed Name Paul Erhardt ACKNOWLEDGMENT Permit Holder's Signature: Printed Name License # (if applicable SPECIAL BUILDING INSPECTOR: 0 Registered Architect and/or ® Licensed Engineer Signatu .of Special Building Insp Printed Name of Special Building Inspector D. Mark LeBlarfc' !, Address of Special Building Inspector 1599 30th Ave. Stllfte 20. Boynton Beach. FL 33426 ssed Seal 1 Date State of Rorida Registration # 35683 Fax # (5611752-5542 Building Official (or designated representative) T&Jephone # (5611 752-5440 Date QBE ADVISED THIS DOES NOT PRECLUDE YOU FROM OTHER MANDATORY INSPECTIONS IN THE CODE*'° G:ISHAREDIF„rno120I0 FBC Special Bldg Insp Form.doc GALE INSULATION SIO # 401731864/401757676 CERTIFICATE OF INSULATION — INSTALLATION BUILDING PERMIT # OLP6I )‘"03 O.° 4 5 JOB ADDRESS: 11569 NW 79 MANOR PARKLAND, FL LOT 810 OSPREY LAKE STATEMENT OF COMPLIANCE: We, the undersigned, hereby certify that the thermal insulation has been installed in the referenced building in compliance with the Florida Model Energy Efficiency Building Code and the approved plans and specifications, and in accordance with good construction practice. The insulation furnished is of the type, thickness and R -value as set forth below: AREA TYPE THICKNESS R -VALUE MANUFACTURER I CEILING AREA FIBERGLASS 12.75" ! 12" R-38 OWENS CORNING 167FLR/NOT BLOW/BATT ACCESSIBLE INTERIOR FIBERGLASS 3.5" R-11 OWENS CORNING PARTITIONS BATT GARAGE FIBERGLASS 3.5" R-11 OWENS CORNING COMMON WALL BATT EXTERIOR REFLECTIVE .75 R-4.1 FI -FOIL COMPANY MASONRY FOIL WALLS INSULATION CGC1512179 ERT (CATION DATE: GUST , 2014 INSULATION CONTRACTOR'S SIGNATURE: BUILDER: WCI COMMUNITIES : SIGNATURE: I PERSONALLY KNOW THE AFFIANT, PAMELA FENTON. Sworn to and subscribed before me this / 9 day of Glu , , 2014 Notary Public, State of Florida % e - r ✓✓`''� P,•'t MARUS C SMITH-DOBLER E.( MY COMMISSION #FF112303 , ••• • f 0 EXPIRES May 9. 2018 (407) 398-0153 FloridallotaryService.com January 13, 2014 SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach LETTER OF INTENT FOR SPECIAL INSPECTOR FOR TRUSS ERECTION City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North — Osprey Lakes Plat 3 — Lot 10H 11569 NW 79 Manor, Parkland, FL 33076 Building Department: Please be advised that we, Specialty Engineering Consultants; Inc, have been retained by WCI Communities, LLC to supervise the erection of trusses with bottom chord in excess of 35' or height greater than 6' in accordance with Section 2319.17.2.4 of the Florida Building Code for the referenced project. This letter of intent is to be followed up by an Inspection Certification for truss erection which attests to the above. Respectfully submitted, Specialty Engineering Consultants, Inc. State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach STATEMENT OF INTENT AND SCOPE OF WORK FOR ENGINEERED UNIT MASONRY January 13, 2014 City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North — Osprey Lakes Plat 3 — Lot 10H 11569 NW 79 Manor, Parkland, FL 33076 Building Department: We, Specialty Engineering Consultants; Inc, shall personally inspect the entire "Engineered Unit Masonry" system for this building, including but not limited to the following: 1. Masonry units, mortar, grout and reinforcing steel met specifications. 2. Dowels properly placed with adequate spacing. 3. Steel column ties in columns, pilasters and beam elevation transitions properly placed, tapped and tied. 4. Masonry field work: head and bed joints, horizontal joint reinforcing installed correctly, cells free of excessive mortar fins, walls level and plumb tolerances. 5. Monitor grout placement, verify grout slump, proper consolidation of grout and proper low or high lift grouting procedures were followed. 6. Correct embedment of reinforcing steel, bolts, ties, etc. 7. Compliance with ACI 530-08/ASCE 5-08 and commentaries, approved plans and 2010 FBC. This letter of intent is to be followed up by an Inspection Certification for Unit Masonry which attests to the above. Respectfully submitted, Specialt gineringConsultants D. Mark L Partne nc, PE State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5f THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR. (O a 21- CJI- J d c, a. X N 1- U CC H W N 2 CC W 2 0 0 1-- U 20 CC z U N W <NC COI - I - w M- I -O[0 23 aCw ZN •0ON 0 w 0 L) J J C N 1- a C ~ 1- - U- CC C - H U O 0 >- LU F -N2 03 C._) CO » Z w CC 0 CI - C 00 0 2 SI- N 0 ~ 0 *k U w W 0_W0 C- V)U= UJJ QLO xn O 11-CL 1 0 a O W W N 2 L) J W NOa -0) CO 0 N 2 I- XI- C N N V) WC7 CO -1 COW • -`CH < N CO s. --,N Z -I < J U • U V) L0 N zowI- CC a C I- 0 0 M (/)2Z w0 (N N - 0 1- 2 C 1- C o o W O ~ a(2/) am V) w 2 -o0 1- i.) 2wz w - CD 2 I- a < 0 -00 I- N 00 O] - -0a .- } U I- CO I - J< I-2 4( a -C 2 N C C m W U 0 W a `c O_ C V) W 2 • ao- U- 0 o oa2 < w wI- J0 �-- 0 -HLL aZ a < 0 w Y U Cl- W F- 0 M W COC0 QZ C Z o w ,-•o I- - a x ,- =no • 1 -LL CO �� 1— ce wJ 1— (O (./) - w C a) z V)2 Cf - Cb -a01- Oa 0- • C O_CL0 U N 0) ON ZLLI 2 C 0 0Y -U 2 3 O - 0W < C L_ CO 2I- 0 0 CO L Q CC Z W 1.1.1.1.1 C0 0002 2 00� 0 _-00 3 U) I- O_ V) - UJ (0 - 21.1..1N CZC In LL C V) 011.1 - 0 L.J 1 01- 0 0 < 03 O ->w a.WM o C CC 2 w w 1-W I- 0 O_ a 1- OO C a n J LU N 3 w NaCC CC w O I- 2.0 CO L 0 C x S .� CN 2 1 -NU HIBC LOT 741 BE CORRECTLY PLACED 0 W 0 0 CO } J J LL 0 < I- U C =0 LLI 0 ▪ 0 • (n Z w O U 14— ax z a — o c� O w ca J ▪ ce CL W a X V) N Q PLATE MUST BE N O W Oce 0 O W S I- U J a1- ao N 0o 0 h 17-4-0 Over 2 Supports - E 0) C E 0) v a) h N LO 2 � - n O u, LO I I I I J C CC =.375"/Ft. (0 M • V O) (o \ w I— N LO LO(- O 0) CO U H V) UJ Q ce d' 0 0 HCUSR8975 14141284 1V6K8975Z03 C7 Z M Li 1 ▪ d 0 W U W Cd = Cn u. -1 <L w Li.. IJ Li. a aa aa 1 ce N 00 0 O 0 (f In \ 0 Q CD 1 J J J J J U- --I O D J CL Q I- I--- 03 m O- - O N Design Crit: TRUSS REPAIR ALLOWABLE UPLIFT = 4950 LBS UJ ul (±13 CD m LU O co • W� • No> p U W O LU w O CD tZ W e Z Q z 3 N < W p Q CC w OC - 0 E3 • pz gw m � 0c=n(vi) m J O M W W O FW- O WCD N w F- Li (n 0 J oM MD ul = z A _ ,s, O V a U U icy O 33 Q LU J ¢¢ J (iJ W W (i Z CO CC 0 O a p O Z N CC Z O CO o� rw M V) Z wo 0 0 a 0< M CC d 0 LC) x U r-- < Q O M CLCO M CL . ie N W O CC a CC w CCz LLI O U z 1 0 U W z Oa U � n /CDL'A Q Pltl 60 LOT KOVer./i, THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR. F - •z UJ W CD a Z - W J a X N U NO C U1 •2 2 OF_- U O Z x03 a- < V) a m I- I-- 3 )4 g- I- 0 CO 3 QCW a V) •om ON co UJ <I- ~ J U H N 1-< C C -F- U0 H 3 0 > W F- V) 2 CO U WNt7 Q m C 0 3 LL CF -C 00 O 2 2F - N0~ V)0 i k ) W W aW0 C- V) U = 4.1 <.t, 20- 0 1.1- 3a 0ww N Z U J W CV XO OO.. • u)0 V) •ZF- XF- C V) N V) W C CO -.103W5 r.Q-iF- '-UQOCi) m �N Z J Q J U U V) • N 000 = ZWF- C V)22 W0 NN- 01- R00 W0 (11 U. W2 O 0 F - Z F - 4Q 03 VI 0 - 0 < u <- 20 0 W Q m 5 U L d O - 0 - _ W O 5 1- < F- r ¢ < 0 wa Y M CL UJ WOOC7 QZ C 2 J W R UJ VI aF- i H5 -V)• C~JW n 0N -W CJ o cco-<0F2-- 0Q n C - Caa0 0 V) CA 0V) 2W -J 2 3 0 w< C LQL C.) G0 L.Q0(. Z O2 Oa -0 00 2 - In 1-a V)- UJ CO .- MU -IV) CZC LU 2 0E- 0NO 0 ¢000 0 C C2=W W 1-W N F-0 a<F-CO 12Q5 0. L G Cf) O.. W d 3 W N C C 0.G 0 CX2 `. CN 2 F -NU 1 a- r o 0 j-/tt-.13.- \ "lij1 CP 0 w U J a } J 0 w 0 0 00 0 w, 0 LLL n 0) 1- L(/) U 2. N I- O 0 I- 0. - I- M - 0 CD Z Z m O a3 I- 0 awCLw - N Q a ,- 0 Z 0 u - W 0 N 0 00 41 I--C..) a0 I- x N CO 0 C CO 0 n rr- E o R=972 U=262 W=8" Scale =.375"/Ft. W LL F- W Q CC 0 DRW HCUSR8975 14141284 O. rn \ 0) CO N LN/) 0 C7 -4 21 W Z = LL 1 a 0 W U W = = V) LL - 1V6K8975Z03 LL U. LL L.L. LL , a O. 0.. a a w O 0 0 0 0 N O 0 00 0 \ M r r to \ 0 < Z 1 J J J J J I.L. - J J O O JM Q u. U C.) C.) U 0 0 0. I- H CO 00 I- 0 N 0 >- PLT TYP. Wave TRUSS REPAIR X4,1 ooW� W jFj i W O iE ��rc a aLaoiRX EPIXgId gpip Ogni ful!1 June 10, 2014 0 1,46 x03 p D 2,s" SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR TRUSS ENGINEERING City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North — Osprey Lakes Plat 3 — Lot 10H 11569 NW 79 Manor, Parkland, FL Permit #: 1403-0025 Building Department: We have personally inspected the truss system on the above referenced property and find the trusses are erected properly and without any apparent damage. We have checked all aspects of this truss system — roof trusses and floor trusses, where used — including, but not limited to the following components. 1. Proper size, grade and species of lumber used in the assembly of each truss per engineering. 2. Nail -on position or press -on plates checked for proper size and position per engineering. 3. Trusses and girders checked for proper anchorage for both gravity loads and uplift Toads. 4. Lateral bracing applied to truss members per engineering and building code. 5. All other bracing to resist lateral forces, in addition to that specified by truss engineering, has been applied as required by the Architect -of -Record's approved plans. This includes the addition of shear walls, let -in wall bracing, floor system bracing, proper positioning of sheathing, etc. We have also inspected arty repaired and/or modified trusses and hake ascertained that they have been corrected in accordance with: "Sealed" repair engineering supplied by the truss engineer. All engineering sheets for repaired and/or modified trusses are included herewith. Respectively submitted, SPECI Y ENGINEE D. M Partner LeBlanc, PE ULTANTS, INC. State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 June 10, 2014 Bot, ND.; -&e s" SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR TRUSS ERECTION City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North — Osprey Lakes Plat 3 — Lot 10H 11569 NW 79 Manor, Parkland, FL Permit #: 1403-0025 Building Department: Please be advised that we, Specialty Engineering Consultants; Inc, monitored the erection of trusses with bottom chord in excess of 35' or height greater than 6' in accordance with Section 2319.17.2.4 of the Florida Building Code for the referenced project. We find that all aspects of this system conform to the approved plans and the Florida Building Code. Respectf y submitted, Spec' . y ngineering Consultants, Inc. rk LeBlanc, PE Part er State of Florida: Registered Professional Engineer #0035683 Registered Special Inspector #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 June 10, 2014 _ , D�, i'4 .0tarSPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR UNIT MASONRY City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North — Osprey Lakes Plat 3 — Lot 10H 11569 NW 79 Manor, Parkland, FL Permit #: 1403-0025 Building Department: We have personally inspected the complete "engineered unit masonry" system for this building. includes all of its components such as; steel placement; horizontal joint reinforcement; vertical reinforcing steel for the concrete masonry units and all associated tie beams, tie columns, etc. have monitored and verified grout placement. We find that all aspects of this system conform to the approved plans and the Florida Building 2122.4 and BCAC 105.10.2.2. Respectively submitted, SPE Af TY ENGINEERING CONSULTANTS, INC. rk LeBlanc, PE Pa ner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 This inspection and horizontal In addition, we Code, sections 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 June 10, 2014 81.16 f 4153-00 ZS' SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach ;SIN 1 6 ?514 CERTIFICATE OF COMPLIANCE FOR TRUSS ERECTION City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North - Osprey Lakes Plat 3 - Lot 10H 11569 NW 79 Manor, Parkland, FL Permit #: 1403-0025 Building Department: Please be advised that we, Specialty Engineering Consultants; Inc, monitored the erection of trusses with bottom chord in excess of 35' or height greater than 6' in accordance with Section 2319.17.2.4 of the Florida Building Code for the referenced project. We find that all aspects of this system conform to the approved plans and the Florida Building Code. Respectfully submitted, Speci_ y Engineering Consultants, Inc. rk LeBlanc, PE Partner State of Florida: Registered Professional Engineer #0035683 Registered Special Inspector #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 June 10, 2014 INVA)1x t LIZ 1102.5".. SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR UNIT MASONRY City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North — Osprey Lakes Plat 3 — Lot 10H 11569 NW 79 Manor, Parkland, FL Permit #: 1403-0025 Building Department: We have personally inspected the complete "engineered unit masonry" system for this building. includes all of its components such as; steel placement; horizontal joint reinforcement; vertical reinforcing steel for the concrete masonry units and all associated tie beams, tie columns, etc. have monitored and verified grout placement. We find that all aspects of this system conform to the approved plans and the Florida Building 2122.4 and BCAC 105.10.2.2. Respectively submitted, SPEC ENGINEERING CONSULTANTS, INC. anc, PE Pa - - r State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 This inspection and horizontal In addition, we Code, sections 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 June 10, 2014 ei-1 ac 14X;-ODZ$' SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach CERTIFICATE OF COMPLIANCE FOR TRUSS ENGINEERING City of Parkland Building Department 6600 University Drive Parkland, FL 33067 Re: PROJECT: Heron Bay North — Osprey Lakes Plat 3 — Lot 10H 11569 NW 79 Manor, Parkland, FL Permit #: 1403-0025 Building Department: We have personally inspected the truss system on the above referenced property and find the trusses are erected properly and without any apparent damage. We have checked all aspects of this truss system — roof trusses and floor trusses, where used — including, but not limited to the following components. 1. Proper size, grade and species of lumber used in the assembly of each truss per engineering. 2. Nail -on position or press -on plates checked for proper size and position per engineering. 3. Trusses and girders checked for proper anchorage for both gravity loads and uplift Toads. 4. Lateral bracing applied to truss members per engineering and building code. 5. All other bracing to resist lateral forces, in addition to that specified by truss engineering, has been applied as required by the Architect -of -Record's approved plans. This includes the addition of shear walls, let -in wall bracing, floor system bracing, proper positioning of sheathing, etc. We have also inspected any repaired and/or modified trusses and have ascertained that they have been corrected in accordance with: "Sealed" repair engineering supplied by the truss engineer. All engineering sheets for repaired and/or modified trusses are included herewith. Respectively submitted, SPEC)1Y ENGINEERING CONSULTANTS, INC. D. M Partner LeBlanc, PE State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. Dade • Broward • Palm Beach THRESHOL ' ECIAL INSP CTION REPORT PROJECT: 41J _ ). / DAY: t3 CLIENT: I / DATE: ') CONTRACTOR: PERMIT No. INSPECTION TYPE: TRACKING #: PROJECT LOCATION: 4PERFORMED BY: MEMBERS / AREAS INSPECTED: DISPOSITION / RESULTS: GENERAL NOTES: 0)v -- ()e( g& t -r T �f Av 1 c @I Respectfully submitted, DISTRIBUTION COPY: Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 Form001 ThresholdSpeaallnspec GG 01/04 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. THRESHOLD/ ECIAL INSPE TION REPORT PROJECT: CLIENT: CONTRACTOR: INSPECTION TYPE: PROJECT LOCATION: Dade • Broward • Palm Beach DAY: DATE: PERMIT No. TRACKING #: PERFORMED BY: akot.,64i C ,/ /gIf(f Ak_ /4-1'04 MEMBERS / AREAS INSPECTED: DISPOSITION / RESULTS: GENERAL NOTES: Respectfully submitted, Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 DISTRIBUTION COPY: Form001 ThresholdSpeciallnspec GG 01/04 1599 S.W. 30th Avenue, Suite #20 • Boynton Beach, FL 33426 • Office: 561-752-5440 • Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. THRESHOL PECIAL INSP CTION REPORT PROJECT: 0Je CLIENT: —a CONTRACTOR: INSPECTION TYPE: yi PROJECT LOCATION: MEMBERS / AREAS INSPECTED: DAY: DATE: PERMIT No. TRACKING #: PERFORMED BY: Dade • Broward • Palm Beach 1,162J) 6/4)///y Aix/Lfld_e_eL 5 /1St .0..e CAAAV-e_ 411144,04A-4-rie_i DISPOSITION 0 RESULTS: GENERAL NOTES: /rui(JL1 (1 Respectfully submitted, DISTRIBUTION COPY: Speciality Engineering Consultants, Inc. D. Mark LeBlanc, PE Partner State of Florida: Registered Professional Engineer: #0035683 Registered Special Inspector: #1177 Form001 ThresholdSpeciallnspec GG 01/04 1599 S.W. 30th Avenue, Suite #20 • n )ynton Beach, FL 33426 • Office: 561-7.52-5440 • Fax: 561-752-5542