Loading...
HomeMy WebLinkAboutMECH1308-0176-ApplicationTHIS CARD MUST BE POSTED IN FRONT AT ALL TIMES City of Parkland PERMIT NUMBER: MECH1308-0176 PERMIT TYPE: A/C CHANGE-OUT SITE ADDRESS: 7713 NW 60 LN TYPE OF IMPROVEMENT: NONE Applicant Information DESCRIPTION: A/C CHANGE-OUT 6600 University Drive Parkland, FL 33067 (954} 753-5447 BUILDING\ENGINEERING PERMIT Contractor Information EAST COAST MECHANICAL 1500 N HIGH RIDGE ROAD BOYNTON BEACH, FL 33426 (954) 772-0972 ISSUED DATE: 8/27/2013 FOLIO NO: 474136120580 CODE YEAR: Owner Information FREEDMAN,MARK S 8168 LONDONBERRY RD NASHVILLE, TN 37221-4652 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. (F.S. 713.135). Notice: In addtion to the requirements of this permit there may be additional restrictions applicable to this property that may be found in Public Records of the County, and there may be additiona permits required from other governmental entities such as water management districts, state agencies or federal agencies. SEQ ID 3 PERMIT EXPIRES 180 DAYS FROM EITHER THE ISSUE DATE OR 90 DAYS FROM THE LAST APPROVED INSPECTION For Inspections please call (954) 753-5447. Inspections are scheduled for same-day inspections up until6:00 AM. Building Official or Authorized Signature Date INSPECTIONS STRUCTURAL INSPECTION TYPE INSPECTOR DATE FINAL** City of Parkland ::f 'SSv~d <6~~7}1,3 Building Permit Application ' .. . ., .. Contact Person: GILLIAN CHUCK EXT 9-2020 www.cityofparkland.org Phone II: (954) 772-0972 E-mail: EQUIPSALES@ECMSERVICE.COM All OF THE FOLLOWING MUST BE FILLED IN BY APPLICANT, ACCORDING TO F.S. 713.135 Business Address 1500 N HIGH RIDGE RD City State Zip Phone# OYNTON BEACH FL 33426 (954) 772-0972 El'lgl'Hftts:Nifflif'~'<::'''t',.,;;~,:' -. . . Work Description: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of permit and that all work will be performed to meet the standards of all laws regulating construction in the City of Parkland, Florida. I understand that a separate permit may be secured for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, BOILERS, TANKS, AIR CONDITIONERS, ROOFING, SHUTIERS, ETC. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATIORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Contractor Notification E-mail: EQU IPSALES@ECMSERVICE.COM Print Name of Qualifier/Builder: JOSE RAMIREZ License number: CAC036812 PRINTED NAME OF NOTARY PUBLIC ~nally known to me Q Produced identification Q Oath taken Q Oath not t~IAN CHUCK • NOTARYiJtJBUG STATE OF FLoRIDA NOTARY PUBLIC SEAL OF Comm* &li17a1 &2 OFFICE: expireS 417/2016 Lf'l . PRINTED NAME OF NOTARY PUBLIC Q Personally known to me ~uced identification NOTARY PUBLIC SEAL ~ COOlm# EE172182 OF OFFICE: Expires 411/2018 oo~~''" lti1~::~~DA Application Approved By: ________ ,_....,.~F--------··-_-_·-_-_··___ Date: 8-2 J _..I) Permit Officer City of Parkland Building Division 6600 University Drive Parkland, FL 33067 Phone 954-753-5447 Fax 954-753-8838 AJC & Mechanical Replacement Information This form and ARI Listing must accompany each permit application for the replacement of Air Conditioning or Mechanical Equipment. Please supply a separate data sheet for each Unit being replaced. Contractor 'h:.ist ~1"'" MfCtriUv\LC.Ct.J Permit Number. ______ _ Job Address 1'11 0 tJw l.Q.Q)~ Ln . Lot 5lS Block Subdivision LQK.es ({;) ·M .. loY\d DATA NEW UNIT Manufacturer C.U. Model# A.H.U. Model# Package Unit Model# _. ARI Reference Number KWHeat Nominal Tons Max Fuse I Breaker Thermostat NO Smoke Detector NO ,,,1 Heat Recover NO· Modify Ducts NO Stand I Curb I Slab YES NO ********************** Change Disconnect YES NO ********************** Need Ladder For Ins ection YES NO Packa e Unit I I Miscellaneous Electric Packa e Unit I I Contractor Signature ~ ~ ~ State License I Registration . CO 3\.k:.a-t ~ Date 2-"· ~ ~ \3 Broward County Certificate of Competency _________________ _ Application Approved by: ___ _ Rev. l/09 /I.UDI ... •••I CERTIFIED™ www .ah rid i recto ry.org This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. Certificate of Product Ratings AHRI Certified Reference Number: 4585443 Date: 8/21/2013 Product: Split System: Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: CA16NA060****A Indoor Unit Model Number: FX4DN(B,F)061 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: 16 SEER PURON AC Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): EER Rating (Cooling): SEER Rating (Cooling): 55500 14.00 16.00 • Ratings followed by an asterisk(") indicate a voluntary rerate of previously published data. unless accompanied with a WAS. which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certif"ocate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certifocate was issued, which is listed above, and the Certifocate No., which is listed below. ©2013 Air-Conditioning, Heating, and Refrigeration Institute ~ UDI Air-Conditioning, Heating, ... •• •• and Refrigeration Institute CERTIFICATE NO.: 130215788730805570 ,. -Pjr wrightsoft• Project Summary Entire House Job: FREEDMAN Date: Aug 21, 2013 By: KSC EAST COAST MECHANICAL Pro· ect Information For: MARK FREEDMAN 7713 NW 60TH LN, PARKLAND, FL 33067 Phone: 305-301-6694 Notes: Desi n Information Weather: Fort Lauderdale Hollywood lnt, FL, US Winter Design Conditions Summer Design Conditions Outside db Inside db Design TO 51 OF 70 OF 19 OF Heating Summary Structure Ducts Central vent (120 cfm) Humidification Piping Equipment load 24124 Btuh 0 Btuh 2490 Btuh 0 Btuh 0 Btuh 26615 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (fP) Air changes/hour Equiv. AVF (cfm) Heating 2703 37842 0.32 202 Simplified Average 0 Cooling 2703 37842 0.16 101 Heating Equipment Summary Make Carrier Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 10.0 kW 34121 Btuh 17 OF 1850 cfm 0.077 cfm/Btuh 0 in H20 Outside db Inside db Design TO Daily range Relative humidity Moisture difference 91 °F 75 OF 16 OF L 50 % 62 gr/lb Sensible Cooling Equipment Load Sizing Structure Ducts Central vent (120 cfm) Blower Use manufacturer's data Rate/swing multiplier Equipment sensible load 38204 Btuh 0 Btuh 2056 Btuh 0 Btuh n 0.96 38488 Btuh Latent Cooling Equipment Load Sizing Structure Ducts Central vent (120 cfm) Equipment latent load Equipment total load Req. total capacity at 0.70 SHR 4883 Btuh 0 Btuh 5086 Btuh 9968 Btuh 48456 Btuh 4.6 ton Cooling Equipment Summary Make Carrier Trade 16 SEER PURON AC Cond CA 16NA060****A Coil FX4DN(B,F)061 AHRI ref 458544$ Efficiency 14.0 EER, 16 SEER Sensible cooling 38850 Btuh Latent cooling 16650 Btuh Total cooling 55500 Btuh Actual air flow 1850 cfm Air flow factor 0.048 cfm/Btuh Static pressure 0 in H20 Load sensible heat ratio 0. 80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ~ ....;r Wrightsoft• Right-Suite®Universai201212.1.06RSU02217 ACC"-Project7 .rup Calc= MJB Front Door faces: N 2013-Aug-21 14:07:48 Page 1