Loading...
BLDG1403-0069-Energy CalculationsFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida -Department of Business and Professional Regulation - Residential Performance Method Project Name: Street: City, State, Zip: Owner: Design Location: Osprey- WILLOW Parkland , FL , WCI Communities, LLC FL, Fort Lauderdale 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows(667.9 a. U -Factor: SHGC: b. U -Factor: SHGC: c. U -Factor. SHGC: d. U -Factor: SHGC: sqft.) Description Dbl, U=0.60 SHGC=0.31 Dbl, U=0.38 SHGC=0.31 Dbl, U=0.68 SHGC=0.29 other (see details) other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types (4240.0 sqft.) a. Slab -On -Grade Edge Insulation b. Floor Over Other Space c. other (see details) Glass/Floor Area: 0.158 New (From Plans) Single-family 1 5 Yes 4240 0 Insulation R=0.0 R=0.0 R= Area 387.56 ft2 132.37 ft2 128.00 ft2 20.00 ft2 4.508 ft. Builder Name: WCI Communities, LLC Permit Office: Parkland Permit Number: Jurisdiction: 163100 9. Wall Types (4404.0 sqft.) a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent c. Frame - Wood, Exterior d. other (see details) 10. Ceiling Types (2771.0 sqft.) a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: AC1, AH: AC1 b. Sup: Attic, Ret: AC2, AH: AC2 12. Cooling systems a. Central Unit b. Central Unit 13. Heating systems a. Electric Strip Heat b. Electric Strip Heat 0.304 14. Hot water systems a. Natural Gas Tankless Area 2014.00 ft2 1616.00 ft2 610.00 ft2 Total Proposed Modified Total Standard Reference I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. OSCAR L Digitally signed by OSCAR L CALLEIA • DN: cn-0SCAR L CALLEIA, PREPARED BY: a -ENGINEERED AIR LLC,ou, DATE: CA L L EJ A email=oscarcPenaineeredaidlc.co Date: 2013.06.19 13:07:42 -04'00' I hereby certify that this building, as designed, is in compliance with the Florida Energy'Code. OWNER/AGEANI -\\�.�'` DATE:\\'r-k b. Conservation features None 15. Credits Loads: 73.08 Loads: 109.63 Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. Insulation Area R=4.1 3639.00 ft2 R=11.0 355.00 ft2 R=19.0 340.00 ft2 R= 70.00 ft2 Insulation Area R=38.0 2771.00 ft2 R= ft2 R= ft2 R ft2 6 300 6 240 kBtu/hr Efficiency 34.8 SEER:14.50 28.8 SEER:14.50 kBtu/hr Efficiency 33.0 COP:1.00 25.0 COP:1.00 Cap: 1 gallons EF: 0.820 Pstat PASS BUILDING OFFICIAL: 3(yszk f T . A DATE: 't - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 6/19/2013 12:50 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7 Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: v Osprey- WILLOW User WCI Communities, LLC 1 WCI Communities, LLC Parkland 163100 Single-family New (From Plans) Design Location TMY Site PROJECT Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: Cross Ventilation: Whole House Fan: FL, Fort Lauderdale FL_FORT_LAUDERDALE Number 1 2 Number 1 2 V 1 Name Block1 Block2 Name AC1 AC2 Area 2014 2226 Area 2014 2226 # Floor Type Space IECC Zone 1 Volume 25182.2 22260 5 4240 2 Yes 270 CLIMATE Design Temp 97.5 % 2.5 % 43 91 BLOCKS SPACES Volume Kitchen Occupants 25182.2 Yes 1 22260 No 5 FLOORS Perimeter Perimeter R -Value Area 1 Slab -On -Grade Edge Insulatio AC1 2 Floor over Garage 3 Floor Over Other Space # Type 1 Hip # Type 1 Full attic 6/19/2013 12:50 PM AC2 AC2 --Materials Barrel tile Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Broward Parkland , FL , Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range 70 75 Bedrooms InfiI ID 1 1 4 1 209 ft 0 ROOF Roof Gable Area Area 2014 ft2 610 ft2 1616 ft2 Roof Solar Color Absor. 2842 ft2 0 ft2 Medium 0.75 ATTIC Ventilation Vent Ratio (1 in) Vented 300 321.5 60 Finished Yes Yes Joist R -Value Cooled Yes Yes Low Heated Yes Yes Tile Wood Carpet 0 0 1 19 0 0 1 0 0 0 1 SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) Area RBS 2624 ft2 N No 0.9 No 0 22.6 IRCC N EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7 CEILING # Ceiling Type Space R-Vaiue 1 Under Attic (Vented) AC1 38 WALLS Area 2771 ft2 Framing Frac Truss Type u.11 Wood Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt To Wall Typa Space p_v_abi. Ft In Pt I . - - .. Le .. °. 1 NW=>S Exterior Concrete Block - Int Insul AC1 4.1 9 0 22 0 198.0 ft2 0 0 0.5 0 2 NE=>NW Garage Frame - Wood AC1 11 7 0 10 0 70.0 ft2 0 0.23 0.5 0 3 NW=>S Garage Frame - Wood AC1 11 17 0 10 0 170.0 ft2 0 0.23 0.5 0 4 NW=>S Exterior Concrete Block - Int Insul AC1 4.1 10 0 22 0 220.0 ft2 0 0 0.5 0 5 SW=>SE Exterior Concrete Block - Int Insul AC1 4.1 14 0 22 0 308.0 ft2 0 0 0.5 0 6 NW=>S Garage Frame - Wood AC1 11 5.5 0 10 0 55.0 ft2 0 0.23 0.5 0 7 SE=>NE Exterior Concrete Block - Int Insul AC1 4.1 13 0 12 0 156.0 ft2 0 0 0.5 0 8 NE=>NW Exterior Concrete Block - Int Insul AC1 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 9 NW=>S Garage Frame - Wood AC1 11 6 0 10 0 60.0 ft2 0 0.23 0.5 0 10 NE=>NW Exterior Concrete Block - Int Insul AC1 4.1 10 0 10 0 100.0 ft2 0 0 0.5 0 11 NW=>S Garage Frame - Wood AC1 19 7 0 10 0 70.0 ft2 0 0.23 0.5 0 12 SW=>SE Exterior Concrete Block - Int Insul AC1 4.1 8 0 10 0 80.0 ft2 0 0 0.5 0 13 SE=>NE Exterior Concrete Block - Int Insul AC1 4.1 19.5 0 12 0 234.0 ft2 0 0 0.5 0 14 SE=>NE Exterior Concrete Block - Int Insul AC1 4.1 5 0 12 0 60.0 ft2 0 0 0.5 0 15 NE=>NW Exterior Concrete Block - Int Insul AC1 4.1 8.5 0 10 0 85.0 ft2 0 0 . 0.5 0 16 SW=>SE Exterior Concrete Block - Int Insul AC1 4.1 26 0 12 0 312.0 ft2 0 0 0.5 0 17 SE=>NE Exterior Concrete Block - Int Insul AC1 4.1 5 0 10 0 50.0 ft2 0 0 0.5 0 18 SW=>SE Exterior Concrete Block - Int Insul AC1 4.1 9.5 0 10 0 95.0 112 0 0 0.5 0 19 NE=>NW Exterior Concrete Block - Int Insul AC1 4.1 9.5 0 10 0 95.0 ft2 0 0 0.5 0 20 SE=>NE Exterior Concrete Block - Int Insul AC1 4.1 5.4 0 10 0 54.0 ft2 0 0 0.5 0 21 SW=>SE Exterior Concrete Block - Int Insul AC2 4.1 4.5 0 10 0 45.0 ft2 0 0 0.5 0 22 SW=>SE Exterior Concrete Block - Int Insul AC2 4.1 21 0 10 0 210.0 ft2 0 0 0.5 0 23 NE=>NW Exterior Concrete Block - Int Insul AC2 4.1 18.5 0 10 0 185.0 ft2 0 0 0.5 0 24 SE=>NE Exterior Concrete Block - Int Insul AC2 4.1 12.5 0 10 0 125.0 ft2 0 0 0.5 0 25 NW=>S Exterior Frame - Wood AC2 19 17 0 10 0 170.0 ft2 0 0.23 0.5 0 26 NE=>NW Exterior Concrete Block - Int Insul AC2 4.1 13.5 0 10 0 135.0 ft2 0 0 0.5 0 27 NE=>NW Exterior Concrete Block - Int Insul AC2 4.1 3.5 0 10 0 35.0 ft2 0 0 0.5 0 28 NW=>S Exterior Concrete Block - Int Insul AC2 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 29 SW=>SE Exterior Concrete Block - Int Insul AC2 4.1 14.2 0 10 0 142.0 ft2 0 0 0.5 0 30 SW=>SE Exterior Concrete Block - Int Insul AC2 4.1 4.5 0 10 0 45.0 ft2 0 0 0.5 0 31 SE=>NE Exterior Concrete Block - Int Insul AC2 4.1 15 0 10 0 150.0 ft2 0 0 0.5 0 32 NE=>NW Exterior Concrete Block - Int Insul AC2 4.1 10 0 10 0 100.0 ft2 0 0 0.5 0 33 NE=>NW Exterior Concrete Block - Int Insul AC2 4.1 9 0 10 0 90.0 ft2 0 0 0.5 0 34 SE=>NE Exterior Concrete Block - Int Insul - AC2 4.1 5 0 10 0 50.0 ft2 0 0 0.5 0 35 NW=>S Exterior Frame - Wood AC2 19 12 0 10 0 120.0 ft2 0 0.23 0.5 0 36 NE=>NW Exterior Frame - Wood AC2 19 5 0 10 0 50.0 ft2 0 0.23 0.5 0 6/19/2013 12:50 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7 v' DOORS # Ornt Door Type Space Storms U-Vaiue Width Height Area Ft In Ft In 1 NW=>S Insulated AC1 None .6 6 8 48 ft2 2 NW=>S Insulated AC1 None .35 2.8 8 22.4 ft2 WINDOWS Orientation shown is the entered orientation (=>) changed to Worst Case. Wall Overhang V# Ornt ID Frame Panes NFRC U -Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>SW 1 Metal Low -E Double Yes 0.38 0.31 24.0 ft2 6 ft 0 in 0.01 ft 0 i None None 2 NW=>SW4 Metal Low -E Double Yes 0.6 0.31 39.0 ft2 1.67 ft 0 i 14 ft 0 in None None 3 SW=>SE 5 Metal Low -E Double Yes 0.6 0.31 39.0 ft2 1.67 ft 0 i 14 ft 0 in None None 4 NW=>SW4 Metal Low -E Double Yes 0.38 0.31 32.3 ft2 1.67 ft 01 2 ft 0 in None None 5 SW=>SE 5 Metal Low -E Double Yes 0.38 0.31 32.3 ft2 1.67 ft 0 i 2 ft 0 in None None 6 SE=>NE 7 Metal Low -E Double Yes 0.6 0.31 32.5 ft2 1.67 ft 0 i 14 ft 0 in None None 7 NE=>NW10 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 0 i 2 ft 0 in None None 8 SE=>NE 13 Metal Low -E Double Yes 0.68 0.29 128.0 ft2 11 ft 0 in 1 ft 0 in None None 9 SE=>NE 14 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 0 i 14 ft 0 in None None 10 NE=>NW15 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 0 i 14 ft0 in None None 11 SW=>SE 16 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft0 i 14 ft 0 in None None 12 SE=>NE 17 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 11 ft 0 in 1 ft 0 in None None 13 SW=>SE18 Metal Low -E Double Yes 0.6 0.31 9.0 ft2 1.67 ft 0 i 14 ft 0 in None None 14 NE=>NW19 Metal Low -E Double Yes 0.75 0.25 20.0 ft2 24 ft 0 in 1 ft 0 in None None 15 SW=>SE22 Metal Low -E Double Yes 0.6 0.31 32.3 52 1.67 ft 0 i 2 ft0 in None None 16 SW=>SE22 Metal Low -E Double Yes 0.38 0.31 16.2 ft2 1.67 ft 0 i 2 ft 0 in None None 17 NE=>NW23 Metal Low -E Double Yes 0.6 0.31 32.3 ft2 1.67 ft 0 i 2 ft 0 in None None 18 SE=>NE 24 Metal Low -E Double Yes 0.6 0.31 32.5 52 1.67 ft 01 2 ft 0 in None None 19 NW=>SW25 Metal Low -E Double Yes 0.38 0.31 20.6 ft2 1.67 ft 01 2 ft 0 in None None 20 NE=>NW26 Metal Low -E Double Yes 0.38 0.31 6.9 52 1.67 ft 01 2 ft 0 in None None 21 NE=>NW27 Metal Low -E Double Yes 0.6 0.31 9.0 52 1.67 ft 0 i 2 ft 0 in None None 22 NW=>SW28 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 01 2 ft 0 in None None 23 SW=>SE29 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 01 2 ft 0 in None None 24 SE=>NE 31 Metal Low -E Double Yes 0.6 0.31 16.2 52 1.67 ft 0 i 2 ft 0 in None None 25 NE=>NW32 Metal Low -E Double Yes 0.6 0.31 16.2 52 1.67 ft 01 2 ft 0 in None None 26 NW=>SW35 Metal Low -E Double Yes 0.6 0.31 16.2 52 1.67 ft 01 2 ft 0 in None None GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 747.00003 52 137 52 64 ft 10 ft 1 6/19/2013 12:50 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7 INFILTRATION # Scope Method SLA. CFM 50 ELA E -LA ACH ACH 50- 1 Wholehouse Best Guess .0005 5560.8 305.28 574.12 .4247 7.0327 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 33 kBtu/hr 1 sys#1 2 Electric Strip Heat None COP: 1 25 kBtu/hr 2 sys#2 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14.5 34.8 kBtu/hr 1044 cfm 0.78 1 sys#1 2 Central Unit Split SEER: 14.5 28.8 kBtu/hr 864 cfm 0.75 2 sys#2 v HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt 1 Natural Gas Tankless Garage 0.82 1 gal 80 gal 120 deg FSEC Cert # Company Name None None SOLAR HOT WATER SYSTEM System Model # DUCTS Conservation None Collector Storage Collector Model # Area Volume FEF ft2 — Supply -- — Retum — Air CFM 25 CFM25 HVAC # # Location R -Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft2 AC1 50 ft2 Default Leakage AC1 (Default) (Default) 1 1 2 Attic 6 240 ft2 AC2 106 ft2 Default Leakage AC2 (Default) (Default) 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: jX HeatingCooling Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec entinJan X Feb Feb X Mar X1 Aar pr 1 1 May l 1 Jun X] Jr ul Aul g x] Sep Oct X X Oct X Nov X Dec 6/19/2013 12:50 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/19/2013 12:50 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whale Building Performance Method ADDRESS: PERMIT #: Parkland, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas- and pasand heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat Toss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or -heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 6/19/2013 12:50 PM 1 EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 7 of 7 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 67 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" a. U -Factor: SHGC: b. U -Factor: SHGC: c. U -Factor: SHGC: d. U -Factor: SHGC: Area Weighted Average Area Weighted Average Description Dbl, U=0.60 SHGC=0.31 Dbl, U=0.38 SHGC=0.31 Dbl, U=0.68 SHGC=0.29 other (see details) other (see details) Overhang Depth: SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. Floor Over Other Space c. other (see details) New (From Plans) Single-family 1 5 Yes 4240 Insulation R=0.0 R=0.0 R= Area 387.56 ft2 132.37 ft2 128.00 ft2 20.00 ft2 4.508 ft. 0.304 Area 2014.00 ft2 1616.00 ft2 610.00 ft2 , Parkland, FL, 9. Wall Types a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent c. Frame - Wood, Exterior d. other (see details) 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: AC1, AH: AC1 b. Sup: Attic, Ret: AC2, AH: AC2 12. Cooling systems a. Central Unit b. Central Unit 13. Heating systems a. Electric Strip Heat b. Electric Strip Heat 14. Hot water systems a. Natural Gas b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signatur. Address of New Hom Date: Insulation Area R=4.1 3639.00 ft2 R=11.0 355.00 ft2 R=19.0 340.00 ft2 R= 70.00 ft2 Insulation Area R=38.0 2771.00 ft2 R= ft2 R= ft2 R ft2 6 300 6 240 kBtu/hr Efficiency 34.8 SEER:14.50 28.8 SEER:14.50 kBtu/hr Efficiency 33.0 COP:1.00 25.0 COP:1.00 Cap: 1 gallons EF: 0.82 Pstat City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Project Report mearogrovitimow Project Title: Designed By: Project Date: Client Name: Company Name: Company Representative: Company Address: Company City: Company Phone: Company Fax: Company E -Mail Address: Company Comment: r De t a_Dat Reference City: Building Orientation: Daily Temperature Range: Latitude: Elevation: Altitude Factor: Winter: Summer: rreS Osprey- WILLOW Oscar L. Calleja 6/15/13 WCI Communities, LLC Engineered Air, LLC Oscar L. Calleja 2520 N Andrews Ave. Ext Pompano Beach, FI 33064 954-449-1600 954-973-1883 oscarc@engineeredairlIc.com License No. CAC045860 Outdoor Dry Bulb 46 90.9 Total Building Supply CFM: Square ft. of Room Area: Volume (ft3) of Cond. Space: Total Heatingequired Including Ventilation ir: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: Outdoor Wet Bulb 43.16 78.4 26 10 1.000 E. Fort Lauderdale, Florida Front door faces Northwest Medium Degrees ft. Outdoor Rel.Hum n/a 58% Indoor Rel.Hum n/a 50% Indoor Dry Bulb 70 75 Grains Difference n/a 62 Development, Inc. Osprey WILLOW Page 2 2,600 4,240 45,777 CFM Per Square ft.: Square ft. Per Ton: 41,:41 Btuh 46,738 Btuh 12,952 Btuh 59,690 Btuh 0.613 852 41.841 MBH 78 % 22 4.97 Tons (Based On Sensible + Latent) Ifit . tv Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Willow.rh9 Wednesday, June 19, 2013, 1:04 PM vac - Residential & Light:Gommercial HVAC Loads Engineered Air LIC Margate, FL, -3 3 Total Building Summary Loads (cont'd) e Software Developnent, Inc. M1t1LiOW' 1?ag�4 �m ,� ,-.� .., mow?, ..: � v rnk �� 11111 Be sure to select a unit that meets both sensible and latent Toads according to the manufacturer's performance data at your design conditions. C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Wllow.rh9 Wednesday, June 19, 2013, 1:04 PM Rhvac Residential & 1 Eri neefed Air L1.0 of ate L_ 33 3 Total Building Summary Loads htGommerciai HVAC Loads 1te.,S ?ftware pevet.opplent Osbre W#'Lt 0UV Palle 31 WCI-FixGl: Glazing-WCI-Fixed Glass, u -value 0.38, SHGC 0.31 WCI-SH: Glazing-WCI-SH-dbl-low-e, u -value 0.6, SHGC 0.31 WCI-FixGI: Glazing-WCI-Fixed Glass, u -value 0.38, SHGC 0.31 WCI-SlidinfGl: Glazing-WCI-Sliding GI dbl-low e, u -value 0.68, SHGC 0.29 WCI-SH: Glazing-WCI-SH, u -value 0.6, SHGC 0.31 97.2 1,401 WCI-French: Glazing-WCI-French Door, u -value 0.75, 20 360 SHGC 0.25 48 11J: Door -Metal - Fiberglass Core 11N: Door -Metal - Polystyrene Core 22.4 13A-4ocs: Wall -Block, board insulation only, R-4 board 2959.9 insulation, open core, siding finish 12B-Obw: Part -Frame, R-11 insulation in 2 x 4 stud 332.6 cavity, no board insulation, brick finish, wood studs 70 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, no board insulation, siding finish, wood studs 12E-Obw: Wall -Frame, R-19 insulation in 2 x 6 stud 303.2 cavity, no board insulation, brick finish, wood studs 16D-38: Roof/Ceiling-Under Attic with Insulation on Attic 2771.8 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-38 insulation 22A-pI-c: Floor -Slab on grade, No edge insulation, no 113 2,682 insulation below floor, carpet covering, passive, light dry soil 22A -p►: Floor -Slab on grade, No edge insulation, no 96 2,280 insulation below floor, any floor cover, passive, light dry soil 20P -19-c: Floor -Over open crawl space or garage, 610.2 732 Passive, R-19 blanket insulation, carpet covering Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 221, Summer CFM: 173 Ventilation: Winter CFM: 0, Summer CFM: 0 AED Excursion: Total Building Load Totals: Total Building Supply CFM: Square ft. of Room Area: Volume (ft3) of Cond. Space: 30.9 281 290.3 101.5 128 4,183 924 2,089 691 157 10,156 645 136 495 1,728 2,600 4,240 45,777 Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: 41,841 46,738 12,952 59,690 6 80 28,940 7,057 5,844 0 0 855 855 0 8,750 8,750 0 2,636 2,636 0 2,169 2,169 0 2,658 2,658 0 588 588 0 775 775 0 118 118 0 6,854 6,854 0 484 484 0 102 102 0 254 254 0 2,227 2,227 0 0 0 0 0 0 0 333 333 0 28,803 1,560 1,380 2,300 5,000 273 1,763 7,457 7,329 3,029 0 0 0 796 41,841 12,952 46,738 CFM Per Square ft.: Square ft. Per Ton: Btuh Btuh Btuh Btuh 28,803 2,940 7,300 273 9,220 10,358 0 796 59,690 0.613 852 111,11 41.841 MBH 78 % 22 % 4.97 Tons (Based On Sensible + Latent) ` bt1 i -fa ft -01 > d ee M..,. Sof Ste C''. .3 . Rhvac is an AC8A approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Willow.rh9 Wednesday, June 19, 2013, 1:04 PM Rhvac Res dentiat &Light Commercial MVAC Loads Engineered Air LLC' Margate, FL.; Rhvac Res denfiatl Engineer Margate, Equipment Data - System 1 - AC -1 Light "Corrnme ctal HVAC Loads Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: AHRI Reference No.: Nominal Capacity: Efficiency: Heating System Type: Model: Capacity: Efficiency: Standard Air Conditioner CA16NA036****A FB4CNF042 16 SEER PURON AC CARRIER AIR CONDITIONING 4584647 34800 14.5 SEER Electric Resistance 10 KW 0 0% are Develop,?nenj Osprey- This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90.9F, SOWB: 78.4F, WODB: 46F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 24,997 Btuh, Lat. gain: 7,041 Btuh, Sen. loss: 21,856 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F, Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 20F, Req. clg. airflow: 1137 CFM, Req. htg. airflow: 994 CFM e7:1 C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Willow.rh9 Wednesday, June 19, 2013, 1:04 PM Rhvac Residential^& Light Commercial HVAC Loads T Engineered Air, LIC'`_ Margate, FL; 33063 Equipment Data - System 2 - AC -2 ofware Deveiopthent Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: AHRI Reference No.: Nominal Capacity: Efficiency: Heating System Type: Model: Capacity: Efficiency: Standard Air Conditioner CA16NA030****A FB4CNF036 16 SEER PURON AC CARRIER AIR CONDITIONING 4584321 28800 14.5 SEER Electric Resistance 8 KW 0 0% ge;8 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90.9F, SOWS: 78.4F, WODB: 46F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 21,741 Btuh, Lat. gain: 5,910 Btuh, Sen. loss: 19,985 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F, Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 989 CFM, Req. htg. airflow: 260 CFM C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Willow.rh9 Wednesday, June 19, 2013, 1:04 PM Rhvac - Residential& Light Commercial; HVAC Loads Eng€neered'Air; Narrate;. F Building Rotation Report lite Softwa 3eve1o) menu Inc. Osprey- WILLOW'. Page 9,. All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces Northwest At least one system with its System Air Type input set to Fixed was changed to Auto during the building rotation. If you want to change this behavior uncheck the option on the General tab of the Select Reports dialog called "Always use Auto for System Air Type for Building Rotation Report." System 1: Zone 1: 1 Foyer-Grd FI 110 101 *119 101 101 101 101 101 1--7 2 Powder & Hall *39 39 39 39 39 39 39 39 1-4 3 Living Room 289 269 *320 293 291 265 275 265 1--10 4 Dining *11 11 11 11 11 11 11 11 1--4 5 Den 130 111 140 *157 132 111 128 141 1-8 6 Den WIC *12 12 12 12 12 12 12 12 1--4 7 Bathroom #4 *55 55 55 55 55 55 55 55 1--5 8 Grd FI Stairs *26 26 26 26 26 26 26 26 1--4 9 Family Room 240 232 258 254 *336 229 326 229 2--8 10 Kitchen & Nook 200 205 *216 203 214 202 207 183 1-9 11 Cabana Bath *97 97 97 97 97 97 97 97 1--6 System 2: Zone 1: 12 Loft WIC 9 9 9 9 9 9 *9 9 1-4 13 Stairs -Loft 135 *167 145 101 145 167 135 101 1--8 14 Laundry 17 17 17 17 17 17 *17 17 1-4 15 Master Bedroom 238 230 231 232 238 230 *246 232 1--10 16 Master WIC 16 16 16 16 16 16 *16 16 1-4 17 Master Bath 104 88 101 *107 94 88 97 107 1--7 18 Master Toilet 23 *28 21 15 21 28 23 15 1--4 19 Bathroom #2 3 3 3 3 3 3 *3 3 1-4 20 Bedroom #2 149 144 *152 146 149 144 146 146 1-8 21 WIC #2 13 13 13 13 13 13 *13 13 1-4 22 Bedroom #3 144 139 140 141 144 139 *148 141 1--8 23 Bathroom #3 4 4 4 4 4 4 *4 4 1--4 24 WIC #3 29 29 29 29 29 29 *29 29 1--4 25 Bedroom #4 98 83 98 *106 95 83 95 106 1--6 26 WIC #4 5 5 5 5 5 5 *5 5 1-4 * Indicates highest CFM of all rotations. Northwest 45° North 90° Northeast 135° East 180° Southeast 225° South 270° Southwest 315° West * Indicates highest value of all rotations. 2,125 2,042 *2,203 2,098 2,201 2,026 2,176 1,986 46,742 44,902 *48,445 46,143 48,398 44,561 47,847 43,685 12,953 12,957 12,955 12,955 *12,959 12,957 12,955 12,955 4.97 4.82 *5.12 4.92 5.11 4.79 5.07 4.72 C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Willow.rh9 Wednesday, June 19, 2013, 1:04 PM Rhvac Residential Engtneered Art L# Ma ate, FL 3063 Building Rotation Report (cont'd) - erdial HVAC loads lite Software Developmentlne: Osprey WILLOW ege l0' 0° Northwest 45° 90° 135° 180° 225° 270° 315° North Northeast East Southeast South Southwest West * Indicates highest value of all rotations. 1,137 1,067 1,218 1,153 *1,219 1,051 1,189 1,041 24,997 23,460 26,782 25,356 *26,814 23,119 26,157 22,898 *7,041 7,041 7,041 7,041 7,041 7,041 7,041 7,041 k[I 2.67 2.54 2.82 2.70 *2.82 2.51 2.77 2.49 45° 90° 135° 1800 225° 270° 315° Northwest North Northeast East Southeast South Southwest West * Indicates highest value of all rotations. 5.2 5.1 F,- 5.0 F- 4.8 *989 21,745 5,912 *2.30 975 21,442 5,916 2.28 985 21,663 5,914 2.30 945 20,787 5,914 2.23 981 21,584 *5,918 2.29 975 21,442 5,916 2.28 986 21,691 5,913 2.30 945 20,787 5,914 2.23 Building Rotation Tonnage 4.7 Northwest North --$ Building Net Tonnage Northeast East Southeast South Southwest West Direction Front door Faces C:\Users\Oscarc\Documents\Elite SoftwarelRhvac 9 Projects\WCI-Willow.rh9 Wednesday, June 19, 2013, 1:04 PM