No preview available
HomeMy WebLinkAboutBLDG1403-0111-Energy CalculationsFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Street: City, State, Zip: Owner: Design Location: Osprey- HIBISCUS f Parkland , FL , WCI Communities, LLC FL, Fort Lauderdale 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windaws(476.2 sqft.) Description a. U -Factor: Dbl, U=0.60 SHGC: SHGC=0.31 b. U -Factor: Dbl, U=0.68 SHGC: SHGC=0.29 c. U -Factor: Dbl, U=0.38 SHGC: SHGC=0.31 d. U -Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types (2731.0 sqft.) a. Slab -On -Grade Edge Insulation b. N/A c. N/A - Glass/Floor Area: 0.174 New (From Plans) Single-family 1 4 Yes 2731 0 Insulation R=0.0 R= R= Area 358.84 ft2 72.00 ft2 24.00 ft2 21.36 ft2 6.775 ft. 0.304 Area 2731.00 ft2 ft2 ft2 Builder Name: WCI Communities Permit Office: Parkland Permit Number: Jurisdiction: 163100 9. Wall Types (2819.5 sqft.) a. Concrete Block - Int Insul, Exterior b. Frame - Steel, Adjacent c. N/A d. N/A 10. Ceiling Types (2731.0 sqft.) a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: AC1 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Natural Gas Tankless b. Conservation features None 15. Credits Total Proposed Modified Loads: 48.02 Total Standard Reference Loads: 73.48 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. OSCAR L Digitally signed by OSCAR L. CALLEJA • DN: cn=OSCAR L. CALLEJA, PREPARED BY:FNr.INFFRFn AIR I I CJ DATE: CCALLEA emaom,cil=osUScarc@engineeredairllcc = Date: 2013.06.04 18:33:01 -04'00' I hereby certify that this building, as designed, is in compliance with the Florida Energy C de. OWNER/AGEN 0..\\.W.Q:\k-k-) DATE:�1 �•-•\ Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. Insulation Area R=4.1 2602.80 ft2 R=11.0 216.70 ft2 R= ft2 R= ft2 Insulation Area R=38.0 2731.00 ft2 R= ft2 R= ft2 R ft2 6 300 kBtu/hr Efficiency 45.5 SEER:14.00 kBtu/hr Efficiency 33.0 COP:1.00 Cap: 1 gallons EF: 0.820 PASS Pstat BUILDING OFFICIAL- .. t 1 ay.. _Wa DATE: 3 - 1 Fc -1 4 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 6/4/2013 5:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Osprey- HIBISCUS User WCI Communities, LLC 1 WCI Communities Parkland 163100 Single-family New (From Plans) Design Location TMY Site PROJECT Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: Cross Ventilation: Whole House Fan: FL, Fort Lauderdale FL FORT LAUDERDALE Number Name 1 Blockl Number Name 1 AC1 V' # Floor Type 1 Slab -On -Grade Edge Insulatio Area 2731 IECC Zone Volume 1 27634.6 4 2731 1 Yes 315 CLIMATE Design Temp 97.5 % 2.5 % 43 91 BLOCKS SPACES Area Volume Kitchen 2731 27634.6 Yes FLOORS Space AC1 # Type Materials 1 Hip Barrel tile # Type 1 Full attic # Ceiling Type 1 Under Attic (Vented) 6/4/2013 5:01 PM Ventilation Vented Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Broward Parkland , FL, Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range 70 75 321.5 60 Low Occupants Bedrooms InfiI ID Finished Cooled Heated 5 4 Perimeter R -Value Area 280 ft 0 2731 ft' ROOF Roof Gable Area Area Roof Solar Color Absor. 2958 ft' 0 ft' Medium 0.75 ATTIC Vent Ratio (1 in) Area 1 SA Tested Yes Yes Yes Tile Wood Carpet 1 0 0 Emitt Emitt Deck Tested Insul. Pitch (deg) No 0.9 No 0 22.6 RBS IRCC 300 CEILING Space R -Value AC1 38 2731 ft' Area 2731 ft' N N Framing Frac 0.11 Truss Type Wood EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 Adjacent # Ornt Tn Wall Type Space 1 NE=>N Exterior Concrete Block - Int Insu! AC1 2 NE=>N Exterior Concrete Block - Int Insul AC1 3 NW=>W Exterior Concrete Block - Int Insul AC1 4 SE=>E Exterior Concrete Block - Int Insul AC1 5 SE=>E Exterior Concrete Block - Int Insul AC1 6 SE=>E Exterior Concrete Block - Int Insul AC1 7 SE=>E Exterior Concrete Block - Int Insul AC1 8 W=>SW Exterior Concrete Block - Int Insul AC1 9 NW=>W Exterior Concrete Block - Int Insul AC1 10 SW=>S Exterior Concrete Block - Int Insul AC1 11 SW=>S Exterior Concrete Block - Int Insul AC1 12 SE=>E Exterior Concrete Block - Int Insul AC1 13 NW=>W Exterior Concrete Block - Int Insul AC1 14 SW=>S Exterior Concrete Block - Int Insul AC1 15 NE=>N Exterior Concrete Block - Int Insul AC1 16 SE=>E Exterior Concrete Block - Int Insul AC1 17 .NE=>N Garage Frame - Steel AC1 18 NW=>W Exterior Concrete Block- Int Insul AC1 19 NE=>N Garage Frame - Steel AC1 20 NW=>W Exterior Concrete Block- Int Insul AC1 21 SW=>S Exterior Concrete Block - Int Insul AC1 22 W=>SW Exterior Concrete Block - Int Insul AC1 23 S=>SE Exterior Concrete Block - Int Insul AC1 _24 NW=>W Exterior Concrete Block - Int Insul AC1 25 SE=>E Exterior Concrete Block - Int Insul AC1 26 NW=>W Exterior Concrete Block - Int Insul AC1 27 NW=>W Exterior Concrete Block - Int Insul AC1 v Ornt 1 NE=>N 2 NE=>N Wall # Ornt ID 1 NE=>N 1 2 NE=>N 2 3 SE=>E 5 4 SE=>E 6 5 W=>SW 8 6 NW=>W 9 Frame Metal Metal Metal Metal Metal Metal Door Type Insulated Insulated Space AC1 AC1 Orientation shown is the Panes NFRC Low -E Double Yes Low -E Double Yes Low -E Double Yes Low -E Double Yes Low -E Double Yes Low -E Double Yes WALLS Cavity R -Vali IP 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 11 4.1 11 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 Width Ft Ip 8.5 0 12.7 12.67 14.2 6 13 15 4 4.6 2.5 16 17 13 12.4 5 12 6.67 6.1 15 14.5 8 5 5 14 14.5 10 11.3 DOORS 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Height Pt In 12 0 10 10 10 10 10 10 10 10 10 10 10 10 11.3 10 10 10 10 10 10 10 10 10 10 10 10 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Aroa 102.0 ft' 127.0 ft' 126.7 ft' 142.0 ft2 60.0 ft' 130.0 ft2 150.0 ft' 40.0 ft' 46.0 ft' 25.0 ft' 160.0 ft2 170.0 ft' 130.0 ft' 140.1 ft' 50.0 ft' 120.0 ft' 66.7 ft' 61.0 ft' 150.0 ft2 145.0 ft' 80.0 ft' 50.0 ft' 50.0 ft' 140.0 ft2 145.0 ft' 100.0 ft' 113.0 ft' Storms U -Value None .6 None .6 Sheathing R_\/alt IP 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Width Ft In 3 2.8 Framing Solar Below Fraction Ahsor Grarde% 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 0.26 0.5 0 O 0.5 0 0.26 0.5 0 0 0.5 0 0 0.5 0 O 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0 O 0.5 0 0 0.5 0 Height Area Ft In 8 24 ft' 8 22.6 ft' WINDOWS entered orientation (=>) changed to Worst Case. Overhang U -Factor SHGC Area Depth Separation Int Shade Screening 0.38 0.31 24.0 ft2 6 ft 0 in 0.2 ft 0 in None None 0.6 0.31 47.2 ft' 1.67 ft 0 i 2 ft 0 in None None 0.6 0.31 9.0 ft' 1.67 ft 0 i 2 ft 0 in Drapes/blinds None 0.6 0.31 33.1 ft' 1.67 ft 0 i 2 ft 0 in None None 0.6 0.31 16.2 ft' 12 ft 0 in 1 ft0in None None 0.6 0.31 16.2 ft2 3 ft 0 in 1 ft 0 in None None 6/4/2013 5:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered orientation (=>) changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRG U -Factor SHGC Area Depth Separation Int Shade Screening 7 SW=>S 11 Metal Low -E Double Yes 0.6 0.31 32.3 ft2 1.67 ft 0 i 2 ft 0 in None None 8 SE=>E 12 Metal Low -E Double Yes 0.6 0.31 32.3 ft2 1.67 ft 0 i 2 ft 0 in None None 9 NW=>W 13 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 35 ft 0 in 1 ft 0 in None None 10 NW=>W 13 Metal Low -E Double Yes 0.75 0.25 21.4 ft2 35 ft 0 in 1 ft 0 in None None 11 SW=>S 14 Metal Low -E Double Yes 0.68 0.29 72.0 ft2 14 ft 0 in 1 ft 0 in None None 12 NE=>N 15 Metal Low -E Double Yes 0.6 0.31 23.6 ft2 1.67 ft 0 i 2 ft 0 in None None 13 NW=>W 18 Metal Low -E Double Yes 0.6 0.31 11.4 ft2 1.67 ft 0 i 2 ft 0 in None None 14 NW=>W 20 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 0 i 2 ft 0 in Drapes/blinds None 15 SW=>S 21 Metal Low -E Double Yes 0.6 0.31 33.1 ft2 1.67 ft 0 i 2 ft 0 in Drapes/blinds None 16 W=>SW 22 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 0 i 2 ft 0 in Drapes/blinds None 17 S=>SE 23 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 0 i 2 ft 0 in Drapes/blinds None 18 NW=>W 24 Metal Low -E Double Yes 0.6 0.31 16.2 ft2 1.67 ft 0 i 2 ft 0 in Drapes/blinds None 19 NW=>W 27 Metal Low -E Double Yes 0.6 0.31 23.6 ft2 1.67 ft 0 i 2 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 492 ft2 492 ft2 64ft 10ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 • 1 Wholehouse Best Guess .0005 3581.7 196.63 369.8 .345 7.7766 HEATING SYSTEM # ' System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 33 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 45.5 kBtu/hr 1850 cfm 0.78 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Garage 0.82 1 gal 70 gal 120 deg None 6/4/2013 5:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 v FSEC Cert # Company Name SOLAR HOT WATER SYSTEM System Model # Collector Storage Collector Model # Are Volume FEF None None ft' DUCTS / -- Supply ---- --- Retum ---- Air CFM 25 CFM25 HVAC # V # Location R -Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft' Attic 40 ft' Default Leakage AC1 (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating X Jan Venting Jan Feb Mar JunSep 8cctt Nov Dec X Feb X Mar 1 I AIM Jun SeX NovDec Feb X Mar [X Apr May lXl Jun lXl Jul lXl Aug X] Sep [X� Oct X' Nov X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling -(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/4/2013 5:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: Parkland, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION Air leakage 402.4 Thermostat & controls 403.1 Ducts 403.2.2 Water heaters Mechanical ventilation Swimming Pools & Spas Cooling/heating equipment Ceilings/knee walls 6/4/2013 5:01 PM SUMMARY OF REQUIREMENT(S) To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. At least one thermostat shall be provided for each separate heating and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. 403.5 Homes designed to operate at positive pressure or with mechanical ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >1 okW must be divided into two or more stages. 405.2.1 R-19 space permitting. CHECK 1 EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 65 The lower the EnergyPerformance Index, the more efficient the home. 1 New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows" a. U=Factor: SHGC: b. U -Factor: SHGC: c. U -Factor: SHGC: d. U -Factor: SHGC: Area Weighted Average Area Weighted Average _ 8. Floor Types a. Slab -On -Grade Edge b. N/A c. N/A New (From Plans) Single-family 1 4 Yes 2731 Description Area Dbl, U=0.60 358.84 ft' SHGC=0.31 Dbl, U=0.68 72.00 ft' SHGC=0.29 Dbl, U=0.38 24.00 ft' SHGC=0.31 other (see details) 21.36 ft' other (see details) Overhang Depth: 6.775 ft. SHGC: 0.304 Insulation Area Insulation R=0.0 2731.00 ft' R= ft' R= ft' , Parkland, FL, 9. Wall Types a. Concrete Block - Int Insul, Exterior b. Frame - Steel, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: AC1 12. Cooling systems a. Central Unit Insulation Area R=4.1 2602.80 ft' R=11.0 216.70 ft' R= ft' R= ft2 Insulation Area R=38.0 2731.00 ft' R= ft2 R= ft' R ft' 6 300 kBtu/hr Efficiency 45.5 SEER:14.00 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 33.0 COP:1.00 14. Hot water systems a. Natural Gas b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signat pQk.K"\jk Date: 3l \l.1 Address of New Home: LA ‘\5N. City/FL Zip: Cap: 1 gallons EF: 0.82 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Osprey- HIBISCUS HVAC Load Calculations for WCI Communities, LLC RHVACRim:limnAL, HVAC LOADS Prepared By: Oscar L. Calleja Engineered Air, LLC 2520 N Andrews Ave. Ext Pompano Beach, FI 33064 954-449-1600 Tuesday, June 04, 2013 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads - Engineered Air, LLC Margate, FL 33063 Project Report General Project Information Project Title: Designed By: Project Date: Client Name: Company Name: Company Representative: Company Address: Company City: Company Phone: Company Fax: Company E -Mail Address: Company Comment: Design Data Reference City: Building Orientation: Daily Temperature Range: Latitude: Elevation: Altitude Factor: Winter: Summer: Osprey- HIBISCUS Oscar L. Calleja 5/30/2013 WCI Communities, LLC Engineered Air, LLC Oscar L. Calleja 2520 N Andrews Ave. Ext Pompano Beach, FI 33064 954-449-1600 954-973-1883 oscarc@engineeredairlIc.com License No. CAC045860 Outdoor Dry Bulb 46 90.9 l Check Figures Total Building Supply CFM: Square ft. of Room Area: Volume (ft3) of Cond. Space: 1 Building Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: 26 10 1.000 E. Fort Lauderdale, Florida Front door faces Northeast Medium Degrees ft. Outdoor Outdoor Indoor Wet Bulb Rel.Hum Rel.Hum 43.16 n/a n/a 78.4 58% 50% Elite Software Development, Inc. Osprey- HIBISCUS Page 2 Indoor Grains Dry Bulb Difference 70 n/a 75 62 1,850 CFM Per Square ft.: 2,731 Square ft. Per Ton: 28,078 26,526 Btuh 35,356 Btuh 6,892 Btuh 42,247 Btuh 0.677 776 26.526 MBH 84 % 16 % 3.52 Tons (Based On Sensible + Latent) j Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Hibiscus.rh9 Tuesday, June 04, 2013, 6:30 PM Rhvac - Residential & Light Commercial HVAC Loads Engineered Air, LLC Margate, FL 33063 Elite Software Development, Inc. Osprey- HIBISCUS Page 3 System 1 AC -1 Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain WCI-FixGI: Glazing-WCI-Fixed GI-dbl-low-e, u -value 24 218 0 664 664 0.38, SHGC 0.31 WCI-SH: Glazing-WCI-SH-dbl-low-e, u -value 0.6, SHGC 228.4 3,291 0 6,523 6,523 0.31 WCI-SH: Glazing-WCI-SH-dbl-low-e, light color blinds at 130.4 1,878 0 3,063 3,063 45° with 50% coverage, u -value 0.6, SHGC 0.31 WCI-FrenchD: Glazing-WCI-French Door-dbl-low-e, u- 21.4 384 0 628 628 value 0.75, SHGC 0.25 WCI-SlidinfGl: Glazing-WCI-Sliding GI-dbl-low-e, u -value 72 1,175 0 1,220 1,220 0.68, SHGC 0.29 11J: Door -Metal - Fiberglass Core 46.6 618 0 591 591 13A-4ocs: Wall -Block, board insulation only, R-4 board 2102.6 7,216 0 4,871 4,871 insulation, open core, siding finish 12B-Obw: Part -Frame, R-11 insulation in 2 x 4 stud 194.1 376 0 282 282 cavity, no board insulation, brick finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 2613.4 2,008 0 2,584 2,584 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl-c: Floor -Slab on grade, No edge insulation, no 280 6,646 0 0 0 insulation below floor, carpet covering, passive, light dry soil Subtotals for structure: 23,810 0 20,426 20,426 People: 5 1,400 1,150 2,550 Equipment: 2,000 4,200 6,200 - Lighting: 0 0 0 Ductwork: 0 1,315 6,492 7,807 Infiltration. Winter CFM: 103, Summer CFM: 51 2,716 2,177 900 3,077 Ventilation:. Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 2,188 2,188 System 1 AC -1 Load Totals: 26,526 6,892 35,356 42,247 Check Figures Supply CFM: 1,850 CFM Per Square ft.: 0.677 Square ft. of Room Area: 2,731 Square ft. Per Ton: 776 Volume (ft') of Cond. Space: 28,078 System Loads Total Heating Required Including Ventilation Air: 26,526 Btuh Total Sensible Gain: 35,356 Btuh Total Latent Gain: 6,892 Btuh Total Cooling Required Including Ventilation Air: 42,247 Btuh Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. 26.526 MBH 84 % 16 % 3.52 Tons (Based On Sensible + Latent) C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Hibiscus.rh9 Tuesday, June 04, 2013, 6:30 PM Rhvac - Residential & Light Commercial HVAC Loads Engineered Air, LLC Margate, FL 33063 Equipment Data - System 1 - AC -1 Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: AHRI Reference No.: Nominal Capacity: Efficiency: Heating System Type: Model: Capacity: Efficiency: Standard Air Conditioner CA13NA048*** (A,B) FB4CNF060 13 SEER PURON AC CARRIER AIR CONDITIONING 4542180 45500 14 SEER Electric Resistance 10 KW 0 0% Elite Software Development, Inc. Osprey- HIBISCUS Page 4 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90.9F, SOWB: 78.4F, WODB: 46F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 35,356 Btuh, Lat. gain: 6,892 Btuh, Sen. loss: 26,526 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F, Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 20F, Req. clg. airflow: 1608 CFM, Req. htg. airflow: 1206 CFM C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Hibiscus.rh9 Tuesday, June 04, 2013, 6:30 PM Rhvac - Residential & Light Commercial HVAC Loads Engineered Air, LLC Margate, FL 33063 Building Rotation Report All rotation degree values in this report are clockwise with respect to the projects original orientation. Building orientation as entered (zero degrees rotation): Front door faces Northeast At least one system with its System Air Type input set to Fixed was changed to Auto during the building rotation. If you want to change this behavior uncheck the option on the General tab of the Select Reports dialog called "Always use Auto for System Air Type for Building Rotation Report." individual Rooms Elite Software Development, inc. Osprey- HIBISCUS Page 5 00 450 90° 135° 180° 2250 2700 315° High Rm. Room Rot. Rot. Rot. Rot. Rot. Rot. Rot. Rot. Duct No. Name CFM CFM CFM CFM CFM CFM CFM CFM Size System 1: Zone 1: 1 Foyer 57 62 61 54 71 *94 75 52 1--6 2 Den/Bed #4 161 171 169 154 223 *253 205 154 2--7 3 Powder Bath 26 26 35 *44 35 26 26 26 1--4 4 Dining 74 65 115 *133 98 63 63 72 1--7 5 Kitchen *139 136 136 133 132 133 133 133 1--7 6 Breakfast Nook *112 74 57 62 65 61 82 109 1--7 7 Family Room 313 294 *314 296 265 228 234 274 2--8 8 Living Room 198 *253 186 105 112 131 129 113 2--7 Zone 2: 9 Bathroom #2 *5 5 5 5 5 5 5 5 1--4 10 Bedroom #2 107 143 132 89 137 *151 128 99 1--8 11 Laundry 68 68 68 68 68 68 68 *73 1--5 12 Bedroom #3 113 80 85 115 83 79 105 *124 1--7 13 Hallway & Closet *3 3 3 3 3 3 3 3 1--4 Zone 3: 14 Master Bedroom 347 *362 318 242 285 314 262 294 2--9 15 HER WIC *33 33 33 33 33 33 33 33 1--4 16 HIS WIC *5 5 5 5 5 5 5 5 1--4 17 Master Toilet *1 1 1 1 1 1 1 1 1--4 18 Master Bath 91 53 53 98 84 53 94 *111 1--7 * Indicates highest CFM of all rotations. Whole Building Rotation Front door Supply Sensible Latent Net Degrees Faces CFM Gain Gain Tons 0° Northeast *1,609 *35,390 6,899 *3.52 45° East 1,516 33,342 6,898 3.35 90° Southeast 1,590 34,957 6,892 3.49 135° South 1,465 32,227 6,892 3.26 180° Southwest 1,510 33,212 6,897 3.34 225° West 1,442 31,717 *6,899 3.22 270° Northwest 1,481 32,562 6,899 3.29 315° North 1,461 32,129 6,894 3.25 * Indicates highest value of all rotations. C:\Users\Oscarc\Documents\Elite Software\Rhvac 9 Projects\WCI-Hibiscus.rh9 Tuesday, June 04, 2013, 6:30 PM