HomeMy WebLinkAboutBLDG1312-0001-Energy CalculationsFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Residential Performance Method
Project Name:
Street:
TOLL BROTHERS PARKLAND SAVIERO 2969 2012
lo'-\\'5 CAMQ..(.l\a. ~~\"t.e.*
City, State, Zip: PARKLAND , FL ,
Owner:
Design Location:
--7 ,__, j\
FL, Fort Lauderdale _)
1 . New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned ftoor area above grade (ft2)
Conditioned ftoor area below grade (ft2)
7. Windows(507.0 sqft.)
a. U-Factor:
SHGC:
b. U-Factor:
SHGC:
c. U-Factor:
SHGC:
d. U-Factor:
SHGC:
Description
Sgl, U=0.59
SHGC=0.25
N/A
N/A
N/A
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types (2309.0 sqft.)
a. Slab-On-Grade Edge Insulation
b. Floor over Garage
c. N/A
New (From Plans)
Single-family
4
No
2969
0
Insulation
R=O.O
R=11.0
R=
Area
507.00 ft2
ft2
ft2
2.925 ft.
0.250
Area
1985.00 ft2
324.00 ft 2
ft2
Builder Name:
Permit Office:
Permit Number:
Jurisdiction:
9. Wall Types (4113.0 sqft.)
a. Concrete Block-lnt lnsul, Exterior
b. Frame-Wood, Exterior
c. Frame -Wood, Adjacent
d. N/A
10. Ceiling Types (2369.0 sqft.)
a. Under Attic (Vented)
b. N/A
C. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
b. Sup: Attic, Ret: Attic, AH: 2nd Floor
12. Cooling systems
a. Central Unit
b. Central Unit
13. Heating systems
a. Electric Strip Heat
b. Electric Strip Heat
14. Hot water systems
a. Natural Gas
b. Conservation features
None
15. Credits
Glass/Floor Area: 0.171 Total Proposed Modified Loads: 68.06
Total Standard Reference Loads: 87.91
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
PREPAREDBY: ~~~~-~~~~--~==~----= Code. ~ · ¥./
DATE: ~__?7 / 2
I hereby certify that this buildin
with the Florida Energ.r:=:~K;::;
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
-Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
11/28/2012 11:40 AM EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software
Insulation Area
R=4.1 1932.00 ft2
R=19.0 1740.00 ft 2
R=11.0 441.00 ft2
R= ft2
Insulation Area
R=38.0 2369.00 ft2
R= ft2
R= ft2
R ft2
6 296.9
6 296.9
kBtu/hr Efficiency
41.5 SEER:14.50
23.4 SEER:14.50
kBtu/hr Efficiency
31.0 COP:1.00
15.5 COP:1.00
Cap: 50 gallons
EF: 0.590
Pstat
PASS
Page 1 of6
'
PROJECT
Title: TOLL BROTHERS PARKLAN Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 2969 Lot# 71 D
Owner: Total Stories: 2 Block/SubDivision: PARKLAND G&CC
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: BROWARD
Jurisdiction: Whole House Fan: City, State, Zip: PARKLAND,
Family Type: Single-family FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
v IECC Design Temp lnt Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
---FL, Fort Lauderdale FL_FORT _LAUDERDALE 1 43 91 70 75 321.5 60 Low
BLOCKS
Number Name Area Volume
1 Block1 1985 19850
2 Block2 984 8856
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms lnfiiiD Finished Cooled Heated
1 1st Floor 1985 19850 Yes 18 2 1 Yes Yes Yes
2 2nd Floor 984 8856 No 16 2 1 Yes Yes Yes
FLOORS
v # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
---1 Slab-On-Grade Edge Insulation 1st Floor 211 ft 0 1985 ft2 ----0 0 1
---2 Floor over Garage 2nd Floor --------324ft> 11 0 0 1
ROOF
v Roof Gable Roof Solar SA Em itt Em itt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested lnsul. (deg)
---1 Hip Composition shingles 2501 ft2 0 ft2 Dark 0.96 No 0.9 No 0 22.6
ATTIC
v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC
1 Full attic Vented 300 2309 ft2 N N --
11/28/201211:40 AM EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software Page 2 of6
CEILING
v # Ceiling Type Space R-Value Area Framing Frac Truss Type
---1 Under Attic (Vented) 1st Floor 38 1385 ft2 0.11 Wood
---2 Under Attic (Vented) 2nd Floor 38 984 ft2 0.11 Wood
WALLS
Jlt Adjacent Space Cavity Width Height Sheathing Framing Solar Below
nrnt T;, W:oiiTvn~> R-V:ollo~> Ft In Ft In Ar1>:o R-V:ohoP Fr:or.tinn Ah"'nr r.r:orh>'ll.
1 N=>NE Exterior Concrete Block -lnt lnsul 1st Floor 4.1 62 10 620 ft2 0 0.75 0 --
2 NE=>E Exterior Concrete Block -lnt lnsul 1st Floor 4.1 4 10 40 ft 2 0 0.75 0 --
3 E=>SE Exterior Concrete Block-lnt lnsul 1st Floor 4.1 12 10 120 ft 2 0 0.75 0 --
4 SE=>S Exterior Concrete Block-lnt lnsul 1st Floor 4.1 4 10 40 ft2 0 0.75 0 --
5 S=>SW Exterior Concrete Block -In! lnsul 1st Floor 4.1 56 10 560 ft 2 0 0.75 0 --
6 SW=>W Exterior Concrete Block-lnt lnsul 1st Floor 4.1 9 10 90 ft2 0 0.75 0 --
7 W=>NW Exterior Concrete Block-lnt lnsul 1st Floor 4.1 16 10 160 ft2 0 0.75 0 --
8 W=>NW Exterior Concrete Block -lnt lnsul 1st Floor 4.1 12 21 252 ft2 0 0.75 0 --
9 NW=>N Exterior Concrete Block -lnt lnsul 1st Floor 4.1 --5 10 50 ft2 0 0.75 0
--10 E=>SE Garage Frame-Wood 1st Floor 11 21 21 441 ft2 0 0.75 0
11 N=>NE Exterior Frame -Wood 2nd Floor 19 --57 10 570 ft2 0 0.75 0
12 E=>SE Exterior Frame -Wood 2nd Floor 19 --30 10 300 ft2 0 0.75 0
13 S=>SW Exterior Frame-Wood 2nd Floor 19 --57 10 570 ft2 0 0.75 0
14 W=>NW Exterior Frame -Wood 2nd Floor 19 --30 10 300 ft2 0 0.75 0
DOORS
v # Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>SE Insulated 1st Floor ---None 0.460000 3 8 24 ft2
2 E=>SE Wood 1st Floor ---None 0.460000 3 8 21.33333
WINDOWS
Orientation shown is the entered orientation (=>lchan!led to As Built (rotated 45 degrees).
J Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation lnt Shade Screening
--1 N=>NE 1 Metal Single (Tinted) Yes 0.59 0.25 22.5 ft2 2ft 0 in 1 ft 0 in None None
---2 NE=>E 2 Metal Single (Tinted) Yes 0.59 0.25 12 ft2 2ft 0 in 1 ft 0 in None None
---3 E=>SE 3 Metal Single (Tinted) Yes 0.59 0.25 18 ft2 2ft 0 in 1 ft o in None None
---4 SE=>S 4 Metal Single (Tinted) Yes 0.59 0.25 12 ft2 2ft 0 in 1 ft 0 in None None
--5 E=>SE 3 Metal Single (Tinted) Yes 0.59 0.25 8 ft2 2ft 0 in 10ft 0 in None None
--6 S=>SW 5 Metal Single (Tinted) Yes 0.59 0.25 30 ft2 2ft 0 in 12ft 0 in None None
---7 S=>SW 5 Metal Single (Tinted) Yes 0.59 0.25 22.5 ft2 2ft 0 in 12ft 0 in None None
---8 S=>SW 5 Metal Single (Tinted) Yes 0.59 0.25 8 ft2 2ft 0 in 12ft 0 in None None
---9 SW=>W 6 Metal Single (Tinted) Yes 0.59 0.25 15 ft2 2ft 0 in 1 ft 0 in None None
---10 W=>NW 7 Metal Single (Tinted) Yes 0.59 0.25 30 ft2 2ft 0 in 1 ft 0 in None None
---11 NW=>N 9 Metal Single (Tinted) Yes 0.59 0.25 15 ft2 2ft 0 in 1 ft 0 in None None
---12 N=>NE 1 Metal Single (Tinted) Yes 0.59 0.25 10 ft2 2ft 0 in 1 ft 0 in None None
---13 W=>NW 8 Metal Single (Tinted) Yes 0.59 0.25 96 ft2 2ft 0 in 1 ft 0 in None None
--14 SW=>W 6 Metal Single (Tinted) Yes 0.59 0.25 10 ft2 12ft0in 1 It 0 in None None
11/28/2012 11:40 AM EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software Page 3 of6
WINDOWS
Orientation shown is the entered orientation(=>) changed to As Built (rotated 45 degrees).
J Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation lnt Shade Screening
---15 W=>NW 7 Metal Single (Tinted) Yes 0.59 0.25 22.5 ft2 10ft 0 in 1 ft 0 in None None
---16 E=>SE 12 Metal Single (Tinted) Yes 0.59 0.25 27 ft2 9ft 0 in 1 ft 0 in None None
---17 E=>SE 12 Metal Single (Tinted) Yes 0.59 0.25 9 ft2 2ft 0 in 1 ft 0 in None None
---18 E=>SE 12 Metal Single (Tinted) Yes 0.59 0.25 22.5 ft2 2ft 0 in 1 ft o in None None
---19 S=>SW 13 Metal Single (Tinted) Yes 0.59 0.25 75 ft2 2ft 0 in 1 ft 0 in None None
---20 S=>SW 13 Metal Single (Tinted) Yes 0.59 0.25 3 ft2 2ft 0 in 1 ft 0 in None None
---21 W=>NW14 Metal Single (Tinted) Yes 0.59 0.25 15 ft2 2ft 0 in 1 ft 0 in None None
---22 W=>NW 8 Metal Single (Tinted) Yes 0.59 0.25 24 ft2 2ft 0 in 1 ft 0 in None None
GARAGE
v # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 440 ft2 116 ft2 64ft 10ft 1 ---
INFILTRATION
# Scope Method SLA CFM50 ELA EqLA ACH ACH50
1 Wholehouse Best Guess 0.000300 2336.32 128.260 241.213 0.25484 4.88327
HEATING SYSTEM
v # System Type Subtype Efficiency Capacity Block Ducts
---1 Electric Strip Heat None COP: 1 31 kBtu/hr 1 sys#1
---2 Electric Strip Heat None COP: 1 15.5 kBtu/hr 2 sys#2
COOLING SYSTEM
v # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
--1 Central Unit None SEER: 14.5 41.5 kBtu/hr 1245 cfm 0.75 1 sys#1
--2 Central Unit None SEER: 14.5 23.4 kBtu/hr 702 cfm 0.75 2 sys#2
HOT WATER SYSTEM
v # System Type SubType Location EF Cap Use SetPnt Conservation
---1 Natural Gas None Garage 0.59 50 gal 70gal 120 deg None
SOLAR HOT WATER SYSTEM
v FSEC Collector Storage
Cert # Company Name System Model # Collector Model # Area Volume FEF
None None ft2 ---
11/28/2012 11:40 AM EnergyGauge® USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4of6
DUCTS
/ ---Supply ------Return ----Air Percent HVAC#
# Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool
---1 Attic 6 296.9 ft2 Attic 74.225 f Default Leakage Attic (Default) c(Default)% 1 1
2 Attic 6 296.9 ft2 Attic 74.225 f Default Leakage 2nd Floor (Default) c(Default)% 2 2
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling NJan NFeb ~Mar ~rpr [~May nJun nJul nAug nsep ~~Oct ~~Nov NDec Heating Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct X Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Type SupplyCFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 1 -Electric Strip Heat 0% 1 -Central Unit
None 0 0 0 2 -Electric Strip Heat 0% 2 -Central Unit
11/28/201211:40 AM EnergyGauge® USA-FlaRes201 0 Section 405.4.1 Compliant Software Page 5 of6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
PERMIT#: I ADDRESS:
• PARKLAND, FL,
MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S)
Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
doors= 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat & 403.1 At least one thermostat shall be provided for each separate heating
controls and cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1
& Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site-recovered energy. Off/timer switch required. Gas heaters
minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool
heaters minimum COP= 4.0.
Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per
equipment
Tables 503.2.3. Equipment efficiency verification required. Special
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >1 OkW must be divided into
two or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
11/28/201211:40 AM EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software
CHECK
Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*= 77
The lower the EnergyPerformance Index, the more efficient the home.
, PARKLAND, FL,
1 . New construction or existing New (From Plans) 9. Wall Types
2. Single family or multiple family Single-family a. Concrete Block-lnt lnsul, Exterior
b. Frame-Wood, Exterior
3. Number of units, if multiple family c. Frame-Wood, Adjacent
4. Number of Bedrooms 4 d. N/A
5. Is this a worst case? No 10. Ceiling Types
a. Under Attic (Vented)
6. Conditioned floor area (ft2) 2969 b. N/A
7. Windows** Description Area C. N/A
a. U-Factor: Sgl, U=0.59 507.00 ft2 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
SHGC: SHGC=0.25 b. Sup: Attic, Ret: Attic, AH: 2nd Floor
b. U-Factor: N/A ft2
SHGC: 12. Cooling systems
c. U-Factor: N/A ft2 a. Central Unit
SHGC: b. Central Unit
d. U-Factor: N/A ft2
13. Heating systems SHGC: a. Electric Strip Heat
Area Weighted Average Overhang Depth: 2.925 ft. b. Electric Strip Heat
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14. Hot water systems
a. Slab-On-Grade Edge Insulation R=O.O 1985.00 ft2 a. Natural Gas
b. Floor over Garage R=11.0 324.00 ft 2
b. Conservation features
C. N/A R= ft2
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Cod · ~
Builder Signature:
Address of New Home:
Insulation Area
R=4.1 1932.00 ft2
R=19.0 1740.00 ft 2
R=11.0 441.00 ft2
R= ft2
Insulation Area
R=38.0 2369.00 ft2
R= ft2
R= ft2
R ft2
6 296.9
6 296.9
kBtu/hr Efficiency
41.5 SEER:14.50
23.4 SEER:14.50
kBtu/hr Efficiency
31.0 COP:1.00
15.5 COP:1.00
Cap: 50 gallons
EF: 0.59
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software
Residential System Sizing Calculation
Summary
Project Title:
TOLL BROTHERS PARKLAND SAVIERO 2969 2012
PARKLAND, FL
11/28/2012
Location for weather data: Fort Lauderdale, FL -Defaults: Latitude(26.2) Altitude(1 0 ft.) Temp Range(L)
Humidity data: Interior RH (50%) Outdoor wet bulb (78F) Humidity difference(64Qr.)
Winter design temperature(MJ8 99%) 50 F Summer design temperature(MJ8 99%) 90 F
Winter setpoint 70 F Summer setpoint 75 F
Winter temperature difference 20 F Summer temperature difference 15 F
Total heating load calculation 31593 Btuh Total cooling load calculation 63140 Btuh
Submitted heating capacity % of calc Btuh Submitted cooling capacity %of calc Btuh
Total (Electric Strip Heat) 147.2 46500 Sensible (SHR = 0.75) 101.6 48675
Latent 106.4 16225
Total 102.8 64900
WINTER CALCULATIONS
Winter HeatinQ Load (for 2969 sqft)
Load component Load
Window total 507 sqft 5983 Btuh
Wall total 3561 sqft 7885 Btuh
Door total 45 sqft 417 Btuh
Ceiling total 2369 sqft 1203 Btuh
Floor total See detail report 5467 Btuh
Infiltration 195 cfm 4290 Btuh
Duct loss 6348 Btuh
Subtotal 31593 Btuh
Ventilation 0 cfm 0 Btuh
TOTAL HEAT LOSS 31593 Btuh
SUMMER CALCULATIONS
Summer CoolinQ Load (for 2969 sqft)
Load component Load
Window total 507 sqft 12886 Btuh
Wall total 3561 sqft 6699 Btuh
Door total 45 sqft 626 Btuh
Ceiling total 2369 sqft 3247 Btuh
Floor total 341 Btuh
Infiltration 146 cfm 2413 Btuh
Internal gain 13620 Btuh
Duct gain 8058 Btuh
Sens. Ventilation 0 cfm 0 Btuh
Blower Load 0 Btuh
Total sensible gain 47891 Btuh
Latent gain( ducts) 2084 Btuh
Latent gain(infiltration) 6366 Btuh
Latent gain(ventilation) 0 Btuh
Latent gain(internal/occupants/other) 6800 Btuh
Total latent gain 15249 Btuh
TOTAL HEAT GAIN 63140 Btuh
8th Edition
EnergyGauge® I USRFZB v3.0
System Sizing Calculations -Summer
Residential Load -Room by Room Component Details
Project Title:
TOLL BROTHERS PARKLAND SAVIERO 2969 2012
PARKLAND, FL
11/28/2012
Reference City: Fort Lauderdale, FL Temperature Difference: 15.0F(MJ8 99%) Humidity difference: 64gr.
Con:tP-?'1e.m.~Pfl~.~, fQr~oQpl #~: 1 s.t_:F,:I.()pr
•' '• ,!. I ~ • • I
• •• \ .. ,"1, -. :-:.-.-•..•
Type* Overhang Window Area(sqft) HTM Load
Window Panes SHGC U lnSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded
1 1 NFRC 0.25, 0.59 No No NE 2.0ft. 1.0ft. 22.5 0.0 22.5 14 26 587 Btuh
2 1 NFRC 0.25, 0.59 No No E 2.0ft. 1.0ft. 12.0 1.3 10.7 14 33 373 Btuh
3 1 NFRC 0.25, 0.59 No No SE 2.0ft. 1.0ft. 18.0 8.0 10.0 14 26 377 Btuh
4 1 NFRC 0.25, 0.59 No No s 2.0ft. 1.0ft. 12.0 12.0 0.0 14 15 171 Btuh
5 1 NFRC 0.25, 0.59 No No SE 2.0ft. 10.0f 8.0 0.0 8.0 14 26 210 Btuh
6 1 NFRC 0.25, 0.59 No No sw 2.0ft. 12.0f 30.0 0.0 30.0 14 26 788 Btuh
7 1 NFRC 0.25, 0.59 No No sw 2.0ft. 12.0f 22.5 0.0 22.5 14 26 591 Btuh
8 1 NFRC 0.25, 0.59 No No sw 2.0ft. 12.0f 8.0 0.0 8.0 14 26 210 Btuh
9 1 NFRC 0.25, 0.59 No No w 2.0ft. 1.0ft. 15.0 2.0 13.0 14 33 460 Btuh
10 1 NFRC 0.25, 0.59 No No NW 2.0ft. 1.0ft. 30.0 0.0 30.0 14 26 782 Btuh
11 1 NFRC 0.25, 0.59 No No N 2.0ft. 1.0ft. 15.0 0.0 15.0 14 14 214 Btuh
12 1 NFRC 0.25, 0.59 No No NE 2.0ft. 1.0ft. 10.0 0.0 10.0 14 26 261 Btuh
13 1 NFRC 0.25, 0.59 No No NW 2.0ft. 1.0ft. 96.0 0.0 96.0 14 26 2502 Btuh
14 1 NFRC 0.25, 0.59 No No w 12.0f 1.0ft. 10.0 10.0 0.0 14 33 143 Btuh
15 1 NFRC 0.25, 0.59 No No NW 10.0f 1.0ft. 22.5 0.0 22.5 14 26 587 Btuh
22 1 NFRC 0.25, 0.59 No No NW 2.0ft. 1.0ft. 24.0 0.0 24.0 14 26 626 Btuh
Window Total 356 (sqft) 8881 Btuh
Walls Type U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
1 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 587.5 2.2 1315 Btuh
2 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 28.0 2.2 63 Btuh
3 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 70.0 2.2 157 Btuh
4 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 28.0 2.2 63 Btuh
5 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 499.5 2.2 1118 Btuh
6 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 65.0 2.2 146 Btuh
7 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 107.5 2.2 241 Btuh
8 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 132.0 2.2 295 Btuh
9 • Concrete Blk,Hollow-Ext 0.15 4.1/0.0 35.0 2.2 78 Btuh
10 Frame -Wood -Adj 0.09 11.0/0.0 419.7 1.4 597 Btuh
Wall Total 1972 (sqft) 4072 Btuh
Doors Type Area (sqft) HTM Load
1 Insulated -Exterior 24.0 13.8 331 Btuh
2 Wood -Garage 21.3 13.8 294 Btuh
Door Total 45 (sqft) 626 Btuh
Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load
1 Vented Attic/DarkShingle 0.025 38.0/0.0 1385.0 1.37 1898 Btuh
Ceiling Total 1385 (sqft) 1898 Btuh
Floors Type R-Value Size HTM Load
1 Slab On Grade 0.0 1985 (ft-perimeter) 0.0 0 Btuh
Floor Total 1985.0 (sqft) 0 Btuh
Zone Envelope Subtotal: 15478 Btuh
EnergyGauge® I USRFZB v3.0 Page 1
Manual J Summer Calculations
Residential Load -Component Details (continued)
Project Title: Climate:FL_FORT _lAUDERDALE
TOLL BROTHERS PARKLAND SAVIERO 2969 2012
PARKLAND, FL
11/28/2012
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
Natural 0.31 19850 0.55 81.0 1337 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 18 X 230 + 5800 9940 Btuh
Sensible Envelope Load: 26754 Btuh
Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.148) 3951 Btuh
Sensible Zone Load 30705 Btuh
Type* Overhang Window Area(sqft) HTM Load
Window Panes SHGC U lnSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded
16 1 NFRC 0.25, 0.59 No No SE 9.0ft. 1.0ft. 27.0 27.0 0.0 14 26 385 Btuh
17 1 NFRC 0.25, 0.59 No No SE 2.0ft. 1.0ft. 9.0 8.0 1.0 14 26 141 Btuh
18 1 NFRC 0.25, 0.59 No No SE 2.0ft. 1.0ft. 22.5 11.9 10.6 14 26 447 Btuh
19 1 NFRC 0.25, 0.59 No No sw 2.0ft. 1.0ft. 75.0 39.8 35.2 14 26 1492 Btuh
20 1 NFRC 0.25, 0.59 No No sw 2.0ft. 1.0ft. 3.0 3.0 0.0 14 26 43 Btuh
21 1 NFRC 0.25, 0.59 No No NW 2.0ft. 1.0ft. 15.0 0.0 15.0 14 26 391 Btuh
Window Total 152 (sqft) 2898 Btuh
Walls Type U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
11 Frame-Wood -Ext 0.08 19.0/0.0 570.0 1.7 943 Btuh
12 Frame -Wood -Ext 0.08 19.0/0.0 241.5 1.7 399 Btuh
13 Frame -Wood -Ext 0.08 19.0/0.0 492.0 1.7 814 Btuh
14 Frame -Wood -Ext 0.08 19.0/0.0 285.0 1.7 471 Btuh
Wall Total 1589 (sqft) 2627 Btuh
Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load
2 Vented Attic/DarkShingle 0.025 38.0/0.0 984.0 1.37 1349 Btuh
Ceiling Total 984 (sqft) 1349 Btuh
Floors Type R-Value Size HTM Load
2 Raised Wood -Adj 11.0 324 (sqft) 1.1 341 Btuh
Floor Total 324.0 (sqft) 341 Btuh
Zone Envelope Subtotal: 7215 Btuh
Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load
Natural 0.31 8856 0.45 65.3 1077 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 16 X 230 + 0 3680 Btuh
Sensible Envelope Load: 11972 Btuh
EnergyGauge® I USRFZB v3.0 Page2
Manual J Summer Calculations
Residential Load-Component Details (continued)
Project Title: Climate:FL_FORT _LAUDERDALE
TOLL BROTHERS PARKLAND SAVIERO 2969 2012
PARKLAND, FL
11/28/2012
Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.329) 3944 Btuh
Sensible Zone Load 15916 Btuh
I
Windows July excursion for System 1 1106 Btuh
July excursion for System 2 0 Btuh
Excursion Subtotal: 1106 Btuh
Duct load 163 Btuh
Sensible Excursion Load 1269 Btuh
EnergyGauge® I USRFZB v3.0 Page 3
Manual J Summer Calculations
Residential Load-Component Details (continued)
Project Title: Climate:FL_FORT _LAUDERDALE
TOLL BROTHERS PARKLAND SAVIERO 2969 2012
PARKLAND, FL
11/28/2012
)svsTEM't~ROUPS-(BLOCK'LOADS) · ·
Sensible Envelope Load 26754 Btuh
Window Excursion 1106 Btuh
Cooling Loads Sensible Duct Load (duct gain multiplier of 0.148) 4114 Btuh
(Includes 163 Btuh due to window excursion)
Sensible ventilation 0 Btuh
For System(s): Zone Sensible gain 31974 Btuh
1 Latent infiltration/ventilation gain 3526 Btuh
Serving Zones: Latent duct gain 1040 Btuh
1 Latent occupant gain 3600 Btuh
Latent other gain 0 Btuh
Total block load 40140 Btuh
Sensible Envelope Load 11972 Btuh
Window Excursion 0 Btuh
Cooling Loads Sensible Duct Load (duct gain multiplier of 0.329) 3944 Btuh
Sensible ventilation 0 Btuh
For System(s): Zone Sensible gain 15916 Btuh
2 Latent infiltration/ventilation gain 2840 Btuh
Serving Zones: Latent duct gain 1043 Btuh
2 Latent occupant gain 3200 Btuh
Latent other gain 0 Btuh
Total block load 23000 Btuh
EnergyGauge® I USRFZB v3.0 Page4
Manual J Summer Calculations
Residential Load-Component Details (continued)
Project Title: Climate:FL_FORT_LAUDERDALE
TOLL BROTHERS PARKLAND SAVIERO 2969 2012
PARKLAND, FL
!wHOLE HOUSE TOTALS
,. ·iii: .. " a -I. '
Sensible Envelope Load All Zones
Sensible Duct Load
Total Sensible Zone Loads
Sensible ventilation
Blower
Whole House Total sensible gain
Totals for Cooling Latent infiltration gain (for 64 gr. humidity difference)
Latent ventilation gain
Latent duct gain
Latent occupant gain (34.0 people @ 200 Btuh per person)
Latent other gain
Latent total gain
TOTAL GAIN
-~.: ......
.. . ' -~·,,;·:.;~·-:~.:::<. _,, c ~ >·,
1. Central Unit #
2. Central Unit #
*Key: Window types (Panes-Number and type of panes of glass)
(SHGC-Shading coefficient of glass as SHGC numerical value)
(U -Window U-Factor)
(lnSh-Interior shading device: none( No), Blinds( B), Draperies( D) or Roller Shades(R))
-For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave, half closed
For Roller shades: Assume translucent, half closed
(IS-Insect screen: none(N), Full( F) or Half(Y.))
(Ornt -compass orientation)
EnergyGauge® I USRFZB v3.0
11/28/2012
39832 Btuh
8058 Btuh
47891 Btuh
0 Btuh
0 Btuh
47891 Btuh
6366 Btuh
0 Btuh
2084 Btuh
6800 Btuh
0 Btuh
15249 Btuh
63140 Btuh
41500 Btuh
23400 Btuh
Version 8
Page 5