No preview available
HomeMy WebLinkAboutBLDG1312-0001-Energy CalculationsFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: Street: TOLL BROTHERS PARKLAND SAVIERO 2969 2012 lo'-\\'5 CAMQ..(.l\a. ~~\"t.e.* City, State, Zip: PARKLAND , FL , Owner: Design Location: --7 ,__, j\ FL, Fort Lauderdale _) 1 . New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned ftoor area above grade (ft2) Conditioned ftoor area below grade (ft2) 7. Windows(507.0 sqft.) a. U-Factor: SHGC: b. U-Factor: SHGC: c. U-Factor: SHGC: d. U-Factor: SHGC: Description Sgl, U=0.59 SHGC=0.25 N/A N/A N/A Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types (2309.0 sqft.) a. Slab-On-Grade Edge Insulation b. Floor over Garage c. N/A New (From Plans) Single-family 4 No 2969 0 Insulation R=O.O R=11.0 R= Area 507.00 ft2 ft2 ft2 2.925 ft. 0.250 Area 1985.00 ft2 324.00 ft 2 ft2 Builder Name: Permit Office: Permit Number: Jurisdiction: 9. Wall Types (4113.0 sqft.) a. Concrete Block-lnt lnsul, Exterior b. Frame-Wood, Exterior c. Frame -Wood, Adjacent d. N/A 10. Ceiling Types (2369.0 sqft.) a. Under Attic (Vented) b. N/A C. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic b. Sup: Attic, Ret: Attic, AH: 2nd Floor 12. Cooling systems a. Central Unit b. Central Unit 13. Heating systems a. Electric Strip Heat b. Electric Strip Heat 14. Hot water systems a. Natural Gas b. Conservation features None 15. Credits Glass/Floor Area: 0.171 Total Proposed Modified Loads: 68.06 Total Standard Reference Loads: 87.91 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy PREPAREDBY: ~~~~-~~~~--~==~----= Code. ~ · ¥./ DATE: ~__?7 / 2 I hereby certify that this buildin with the Florida Energ.r:=:~K;::; Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. -Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 11/28/2012 11:40 AM EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software Insulation Area R=4.1 1932.00 ft2 R=19.0 1740.00 ft 2 R=11.0 441.00 ft2 R= ft2 Insulation Area R=38.0 2369.00 ft2 R= ft2 R= ft2 R ft2 6 296.9 6 296.9 kBtu/hr Efficiency 41.5 SEER:14.50 23.4 SEER:14.50 kBtu/hr Efficiency 31.0 COP:1.00 15.5 COP:1.00 Cap: 50 gallons EF: 0.590 Pstat PASS Page 1 of6 ' PROJECT Title: TOLL BROTHERS PARKLAN Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2969 Lot# 71 D Owner: Total Stories: 2 Block/SubDivision: PARKLAND G&CC #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: BROWARD Jurisdiction: Whole House Fan: City, State, Zip: PARKLAND, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE v IECC Design Temp lnt Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range ---FL, Fort Lauderdale FL_FORT _LAUDERDALE 1 43 91 70 75 321.5 60 Low BLOCKS Number Name Area Volume 1 Block1 1985 19850 2 Block2 984 8856 SPACES Number Name Area Volume Kitchen Occupants Bedrooms lnfiiiD Finished Cooled Heated 1 1st Floor 1985 19850 Yes 18 2 1 Yes Yes Yes 2 2nd Floor 984 8856 No 16 2 1 Yes Yes Yes FLOORS v # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet ---1 Slab-On-Grade Edge Insulation 1st Floor 211 ft 0 1985 ft2 ----0 0 1 ---2 Floor over Garage 2nd Floor --------324ft> 11 0 0 1 ROOF v Roof Gable Roof Solar SA Em itt Em itt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested lnsul. (deg) ---1 Hip Composition shingles 2501 ft2 0 ft2 Dark 0.96 No 0.9 No 0 22.6 ATTIC v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2309 ft2 N N -- 11/28/201211:40 AM EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software Page 2 of6 CEILING v # Ceiling Type Space R-Value Area Framing Frac Truss Type ---1 Under Attic (Vented) 1st Floor 38 1385 ft2 0.11 Wood ---2 Under Attic (Vented) 2nd Floor 38 984 ft2 0.11 Wood WALLS Jlt Adjacent Space Cavity Width Height Sheathing Framing Solar Below nrnt T;, W:oiiTvn~> R-V:ollo~> Ft In Ft In Ar1>:o R-V:ohoP Fr:or.tinn Ah"'nr r.r:orh>'ll. 1 N=>NE Exterior Concrete Block -lnt lnsul 1st Floor 4.1 62 10 620 ft2 0 0.75 0 -- 2 NE=>E Exterior Concrete Block -lnt lnsul 1st Floor 4.1 4 10 40 ft 2 0 0.75 0 -- 3 E=>SE Exterior Concrete Block-lnt lnsul 1st Floor 4.1 12 10 120 ft 2 0 0.75 0 -- 4 SE=>S Exterior Concrete Block-lnt lnsul 1st Floor 4.1 4 10 40 ft2 0 0.75 0 -- 5 S=>SW Exterior Concrete Block -In! lnsul 1st Floor 4.1 56 10 560 ft 2 0 0.75 0 -- 6 SW=>W Exterior Concrete Block-lnt lnsul 1st Floor 4.1 9 10 90 ft2 0 0.75 0 -- 7 W=>NW Exterior Concrete Block-lnt lnsul 1st Floor 4.1 16 10 160 ft2 0 0.75 0 -- 8 W=>NW Exterior Concrete Block -lnt lnsul 1st Floor 4.1 12 21 252 ft2 0 0.75 0 -- 9 NW=>N Exterior Concrete Block -lnt lnsul 1st Floor 4.1 --5 10 50 ft2 0 0.75 0 --10 E=>SE Garage Frame-Wood 1st Floor 11 21 21 441 ft2 0 0.75 0 11 N=>NE Exterior Frame -Wood 2nd Floor 19 --57 10 570 ft2 0 0.75 0 12 E=>SE Exterior Frame -Wood 2nd Floor 19 --30 10 300 ft2 0 0.75 0 13 S=>SW Exterior Frame-Wood 2nd Floor 19 --57 10 570 ft2 0 0.75 0 14 W=>NW Exterior Frame -Wood 2nd Floor 19 --30 10 300 ft2 0 0.75 0 DOORS v # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SE Insulated 1st Floor ---None 0.460000 3 8 24 ft2 2 E=>SE Wood 1st Floor ---None 0.460000 3 8 21.33333 WINDOWS Orientation shown is the entered orientation (=>lchan!led to As Built (rotated 45 degrees). J Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation lnt Shade Screening --1 N=>NE 1 Metal Single (Tinted) Yes 0.59 0.25 22.5 ft2 2ft 0 in 1 ft 0 in None None ---2 NE=>E 2 Metal Single (Tinted) Yes 0.59 0.25 12 ft2 2ft 0 in 1 ft 0 in None None ---3 E=>SE 3 Metal Single (Tinted) Yes 0.59 0.25 18 ft2 2ft 0 in 1 ft o in None None ---4 SE=>S 4 Metal Single (Tinted) Yes 0.59 0.25 12 ft2 2ft 0 in 1 ft 0 in None None --5 E=>SE 3 Metal Single (Tinted) Yes 0.59 0.25 8 ft2 2ft 0 in 10ft 0 in None None --6 S=>SW 5 Metal Single (Tinted) Yes 0.59 0.25 30 ft2 2ft 0 in 12ft 0 in None None ---7 S=>SW 5 Metal Single (Tinted) Yes 0.59 0.25 22.5 ft2 2ft 0 in 12ft 0 in None None ---8 S=>SW 5 Metal Single (Tinted) Yes 0.59 0.25 8 ft2 2ft 0 in 12ft 0 in None None ---9 SW=>W 6 Metal Single (Tinted) Yes 0.59 0.25 15 ft2 2ft 0 in 1 ft 0 in None None ---10 W=>NW 7 Metal Single (Tinted) Yes 0.59 0.25 30 ft2 2ft 0 in 1 ft 0 in None None ---11 NW=>N 9 Metal Single (Tinted) Yes 0.59 0.25 15 ft2 2ft 0 in 1 ft 0 in None None ---12 N=>NE 1 Metal Single (Tinted) Yes 0.59 0.25 10 ft2 2ft 0 in 1 ft 0 in None None ---13 W=>NW 8 Metal Single (Tinted) Yes 0.59 0.25 96 ft2 2ft 0 in 1 ft 0 in None None --14 SW=>W 6 Metal Single (Tinted) Yes 0.59 0.25 10 ft2 12ft0in 1 It 0 in None None 11/28/2012 11:40 AM EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software Page 3 of6 WINDOWS Orientation shown is the entered orientation(=>) changed to As Built (rotated 45 degrees). J Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation lnt Shade Screening ---15 W=>NW 7 Metal Single (Tinted) Yes 0.59 0.25 22.5 ft2 10ft 0 in 1 ft 0 in None None ---16 E=>SE 12 Metal Single (Tinted) Yes 0.59 0.25 27 ft2 9ft 0 in 1 ft 0 in None None ---17 E=>SE 12 Metal Single (Tinted) Yes 0.59 0.25 9 ft2 2ft 0 in 1 ft 0 in None None ---18 E=>SE 12 Metal Single (Tinted) Yes 0.59 0.25 22.5 ft2 2ft 0 in 1 ft o in None None ---19 S=>SW 13 Metal Single (Tinted) Yes 0.59 0.25 75 ft2 2ft 0 in 1 ft 0 in None None ---20 S=>SW 13 Metal Single (Tinted) Yes 0.59 0.25 3 ft2 2ft 0 in 1 ft 0 in None None ---21 W=>NW14 Metal Single (Tinted) Yes 0.59 0.25 15 ft2 2ft 0 in 1 ft 0 in None None ---22 W=>NW 8 Metal Single (Tinted) Yes 0.59 0.25 24 ft2 2ft 0 in 1 ft 0 in None None GARAGE v # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 116 ft2 64ft 10ft 1 --- INFILTRATION # Scope Method SLA CFM50 ELA EqLA ACH ACH50 1 Wholehouse Best Guess 0.000300 2336.32 128.260 241.213 0.25484 4.88327 HEATING SYSTEM v # System Type Subtype Efficiency Capacity Block Ducts ---1 Electric Strip Heat None COP: 1 31 kBtu/hr 1 sys#1 ---2 Electric Strip Heat None COP: 1 15.5 kBtu/hr 2 sys#2 COOLING SYSTEM v # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts --1 Central Unit None SEER: 14.5 41.5 kBtu/hr 1245 cfm 0.75 1 sys#1 --2 Central Unit None SEER: 14.5 23.4 kBtu/hr 702 cfm 0.75 2 sys#2 HOT WATER SYSTEM v # System Type SubType Location EF Cap Use SetPnt Conservation ---1 Natural Gas None Garage 0.59 50 gal 70gal 120 deg None SOLAR HOT WATER SYSTEM v FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 --- 11/28/2012 11:40 AM EnergyGauge® USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4of6 DUCTS / ---Supply ------Return ----Air Percent HVAC# # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool ---1 Attic 6 296.9 ft2 Attic 74.225 f Default Leakage Attic (Default) c(Default)% 1 1 2 Attic 6 296.9 ft2 Attic 74.225 f Default Leakage 2nd Floor (Default) c(Default)% 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling NJan NFeb ~Mar ~rpr [~May nJun nJul nAug nsep ~~Oct ~~Nov NDec Heating Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type SupplyCFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Strip Heat 0% 1 -Central Unit None 0 0 0 2 -Electric Strip Heat 0% 2 -Central Unit 11/28/201211:40 AM EnergyGauge® USA-FlaRes201 0 Section 405.4.1 Compliant Software Page 5 of6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method PERMIT#: I ADDRESS: • PARKLAND, FL, MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per equipment Tables 503.2.3. Equipment efficiency verification required. Special occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >1 OkW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 11/28/201211:40 AM EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software CHECK Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*= 77 The lower the EnergyPerformance Index, the more efficient the home. , PARKLAND, FL, 1 . New construction or existing New (From Plans) 9. Wall Types 2. Single family or multiple family Single-family a. Concrete Block-lnt lnsul, Exterior b. Frame-Wood, Exterior 3. Number of units, if multiple family c. Frame-Wood, Adjacent 4. Number of Bedrooms 4 d. N/A 5. Is this a worst case? No 10. Ceiling Types a. Under Attic (Vented) 6. Conditioned floor area (ft2) 2969 b. N/A 7. Windows** Description Area C. N/A a. U-Factor: Sgl, U=0.59 507.00 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic SHGC: SHGC=0.25 b. Sup: Attic, Ret: Attic, AH: 2nd Floor b. U-Factor: N/A ft2 SHGC: 12. Cooling systems c. U-Factor: N/A ft2 a. Central Unit SHGC: b. Central Unit d. U-Factor: N/A ft2 13. Heating systems SHGC: a. Electric Strip Heat Area Weighted Average Overhang Depth: 2.925 ft. b. Electric Strip Heat Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems a. Slab-On-Grade Edge Insulation R=O.O 1985.00 ft2 a. Natural Gas b. Floor over Garage R=11.0 324.00 ft 2 b. Conservation features C. N/A R= ft2 None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Cod · ~ Builder Signature: Address of New Home: Insulation Area R=4.1 1932.00 ft2 R=19.0 1740.00 ft 2 R=11.0 441.00 ft2 R= ft2 Insulation Area R=38.0 2369.00 ft2 R= ft2 R= ft2 R ft2 6 296.9 6 296.9 kBtu/hr Efficiency 41.5 SEER:14.50 23.4 SEER:14.50 kBtu/hr Efficiency 31.0 COP:1.00 15.5 COP:1.00 Cap: 50 gallons EF: 0.59 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA -FlaRes201 0 Section 405.4.1 Compliant Software Residential System Sizing Calculation Summary Project Title: TOLL BROTHERS PARKLAND SAVIERO 2969 2012 PARKLAND, FL 11/28/2012 Location for weather data: Fort Lauderdale, FL -Defaults: Latitude(26.2) Altitude(1 0 ft.) Temp Range(L) Humidity data: Interior RH (50%) Outdoor wet bulb (78F) Humidity difference(64Qr.) Winter design temperature(MJ8 99%) 50 F Summer design temperature(MJ8 99%) 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 20 F Summer temperature difference 15 F Total heating load calculation 31593 Btuh Total cooling load calculation 63140 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity %of calc Btuh Total (Electric Strip Heat) 147.2 46500 Sensible (SHR = 0.75) 101.6 48675 Latent 106.4 16225 Total 102.8 64900 WINTER CALCULATIONS Winter HeatinQ Load (for 2969 sqft) Load component Load Window total 507 sqft 5983 Btuh Wall total 3561 sqft 7885 Btuh Door total 45 sqft 417 Btuh Ceiling total 2369 sqft 1203 Btuh Floor total See detail report 5467 Btuh Infiltration 195 cfm 4290 Btuh Duct loss 6348 Btuh Subtotal 31593 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS 31593 Btuh SUMMER CALCULATIONS Summer CoolinQ Load (for 2969 sqft) Load component Load Window total 507 sqft 12886 Btuh Wall total 3561 sqft 6699 Btuh Door total 45 sqft 626 Btuh Ceiling total 2369 sqft 3247 Btuh Floor total 341 Btuh Infiltration 146 cfm 2413 Btuh Internal gain 13620 Btuh Duct gain 8058 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 47891 Btuh Latent gain( ducts) 2084 Btuh Latent gain(infiltration) 6366 Btuh Latent gain(ventilation) 0 Btuh Latent gain(internal/occupants/other) 6800 Btuh Total latent gain 15249 Btuh TOTAL HEAT GAIN 63140 Btuh 8th Edition EnergyGauge® I USRFZB v3.0 System Sizing Calculations -Summer Residential Load -Room by Room Component Details Project Title: TOLL BROTHERS PARKLAND SAVIERO 2969 2012 PARKLAND, FL 11/28/2012 Reference City: Fort Lauderdale, FL Temperature Difference: 15.0F(MJ8 99%) Humidity difference: 64gr. Con:tP-?'1e.m.~Pfl~.~, fQr~oQpl #~: 1 s.t_:F,:I.()pr •' '• ,!. I ~ • • I • •• \ .. ,"1, -. :-:.-.-•..• Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U lnSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 1 NFRC 0.25, 0.59 No No NE 2.0ft. 1.0ft. 22.5 0.0 22.5 14 26 587 Btuh 2 1 NFRC 0.25, 0.59 No No E 2.0ft. 1.0ft. 12.0 1.3 10.7 14 33 373 Btuh 3 1 NFRC 0.25, 0.59 No No SE 2.0ft. 1.0ft. 18.0 8.0 10.0 14 26 377 Btuh 4 1 NFRC 0.25, 0.59 No No s 2.0ft. 1.0ft. 12.0 12.0 0.0 14 15 171 Btuh 5 1 NFRC 0.25, 0.59 No No SE 2.0ft. 10.0f 8.0 0.0 8.0 14 26 210 Btuh 6 1 NFRC 0.25, 0.59 No No sw 2.0ft. 12.0f 30.0 0.0 30.0 14 26 788 Btuh 7 1 NFRC 0.25, 0.59 No No sw 2.0ft. 12.0f 22.5 0.0 22.5 14 26 591 Btuh 8 1 NFRC 0.25, 0.59 No No sw 2.0ft. 12.0f 8.0 0.0 8.0 14 26 210 Btuh 9 1 NFRC 0.25, 0.59 No No w 2.0ft. 1.0ft. 15.0 2.0 13.0 14 33 460 Btuh 10 1 NFRC 0.25, 0.59 No No NW 2.0ft. 1.0ft. 30.0 0.0 30.0 14 26 782 Btuh 11 1 NFRC 0.25, 0.59 No No N 2.0ft. 1.0ft. 15.0 0.0 15.0 14 14 214 Btuh 12 1 NFRC 0.25, 0.59 No No NE 2.0ft. 1.0ft. 10.0 0.0 10.0 14 26 261 Btuh 13 1 NFRC 0.25, 0.59 No No NW 2.0ft. 1.0ft. 96.0 0.0 96.0 14 26 2502 Btuh 14 1 NFRC 0.25, 0.59 No No w 12.0f 1.0ft. 10.0 10.0 0.0 14 33 143 Btuh 15 1 NFRC 0.25, 0.59 No No NW 10.0f 1.0ft. 22.5 0.0 22.5 14 26 587 Btuh 22 1 NFRC 0.25, 0.59 No No NW 2.0ft. 1.0ft. 24.0 0.0 24.0 14 26 626 Btuh Window Total 356 (sqft) 8881 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 587.5 2.2 1315 Btuh 2 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 28.0 2.2 63 Btuh 3 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 70.0 2.2 157 Btuh 4 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 28.0 2.2 63 Btuh 5 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 499.5 2.2 1118 Btuh 6 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 65.0 2.2 146 Btuh 7 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 107.5 2.2 241 Btuh 8 Concrete Blk,Hollow-Ext 0.15 4.1/0.0 132.0 2.2 295 Btuh 9 • Concrete Blk,Hollow-Ext 0.15 4.1/0.0 35.0 2.2 78 Btuh 10 Frame -Wood -Adj 0.09 11.0/0.0 419.7 1.4 597 Btuh Wall Total 1972 (sqft) 4072 Btuh Doors Type Area (sqft) HTM Load 1 Insulated -Exterior 24.0 13.8 331 Btuh 2 Wood -Garage 21.3 13.8 294 Btuh Door Total 45 (sqft) 626 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Attic/DarkShingle 0.025 38.0/0.0 1385.0 1.37 1898 Btuh Ceiling Total 1385 (sqft) 1898 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 1985 (ft-perimeter) 0.0 0 Btuh Floor Total 1985.0 (sqft) 0 Btuh Zone Envelope Subtotal: 15478 Btuh EnergyGauge® I USRFZB v3.0 Page 1 Manual J Summer Calculations Residential Load -Component Details (continued) Project Title: Climate:FL_FORT _lAUDERDALE TOLL BROTHERS PARKLAND SAVIERO 2969 2012 PARKLAND, FL 11/28/2012 Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load Natural 0.31 19850 0.55 81.0 1337 Btuh Internal Occupants Btuh/occupant Appliance Load gain 18 X 230 + 5800 9940 Btuh Sensible Envelope Load: 26754 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.148) 3951 Btuh Sensible Zone Load 30705 Btuh Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U lnSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 16 1 NFRC 0.25, 0.59 No No SE 9.0ft. 1.0ft. 27.0 27.0 0.0 14 26 385 Btuh 17 1 NFRC 0.25, 0.59 No No SE 2.0ft. 1.0ft. 9.0 8.0 1.0 14 26 141 Btuh 18 1 NFRC 0.25, 0.59 No No SE 2.0ft. 1.0ft. 22.5 11.9 10.6 14 26 447 Btuh 19 1 NFRC 0.25, 0.59 No No sw 2.0ft. 1.0ft. 75.0 39.8 35.2 14 26 1492 Btuh 20 1 NFRC 0.25, 0.59 No No sw 2.0ft. 1.0ft. 3.0 3.0 0.0 14 26 43 Btuh 21 1 NFRC 0.25, 0.59 No No NW 2.0ft. 1.0ft. 15.0 0.0 15.0 14 26 391 Btuh Window Total 152 (sqft) 2898 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 11 Frame-Wood -Ext 0.08 19.0/0.0 570.0 1.7 943 Btuh 12 Frame -Wood -Ext 0.08 19.0/0.0 241.5 1.7 399 Btuh 13 Frame -Wood -Ext 0.08 19.0/0.0 492.0 1.7 814 Btuh 14 Frame -Wood -Ext 0.08 19.0/0.0 285.0 1.7 471 Btuh Wall Total 1589 (sqft) 2627 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 2 Vented Attic/DarkShingle 0.025 38.0/0.0 984.0 1.37 1349 Btuh Ceiling Total 984 (sqft) 1349 Btuh Floors Type R-Value Size HTM Load 2 Raised Wood -Adj 11.0 324 (sqft) 1.1 341 Btuh Floor Total 324.0 (sqft) 341 Btuh Zone Envelope Subtotal: 7215 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load Natural 0.31 8856 0.45 65.3 1077 Btuh Internal Occupants Btuh/occupant Appliance Load gain 16 X 230 + 0 3680 Btuh Sensible Envelope Load: 11972 Btuh EnergyGauge® I USRFZB v3.0 Page2 Manual J Summer Calculations Residential Load-Component Details (continued) Project Title: Climate:FL_FORT _LAUDERDALE TOLL BROTHERS PARKLAND SAVIERO 2969 2012 PARKLAND, FL 11/28/2012 Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.329) 3944 Btuh Sensible Zone Load 15916 Btuh I Windows July excursion for System 1 1106 Btuh July excursion for System 2 0 Btuh Excursion Subtotal: 1106 Btuh Duct load 163 Btuh Sensible Excursion Load 1269 Btuh EnergyGauge® I USRFZB v3.0 Page 3 Manual J Summer Calculations Residential Load-Component Details (continued) Project Title: Climate:FL_FORT _LAUDERDALE TOLL BROTHERS PARKLAND SAVIERO 2969 2012 PARKLAND, FL 11/28/2012 )svsTEM't~ROUPS-(BLOCK'LOADS) · · Sensible Envelope Load 26754 Btuh Window Excursion 1106 Btuh Cooling Loads Sensible Duct Load (duct gain multiplier of 0.148) 4114 Btuh (Includes 163 Btuh due to window excursion) Sensible ventilation 0 Btuh For System(s): Zone Sensible gain 31974 Btuh 1 Latent infiltration/ventilation gain 3526 Btuh Serving Zones: Latent duct gain 1040 Btuh 1 Latent occupant gain 3600 Btuh Latent other gain 0 Btuh Total block load 40140 Btuh Sensible Envelope Load 11972 Btuh Window Excursion 0 Btuh Cooling Loads Sensible Duct Load (duct gain multiplier of 0.329) 3944 Btuh Sensible ventilation 0 Btuh For System(s): Zone Sensible gain 15916 Btuh 2 Latent infiltration/ventilation gain 2840 Btuh Serving Zones: Latent duct gain 1043 Btuh 2 Latent occupant gain 3200 Btuh Latent other gain 0 Btuh Total block load 23000 Btuh EnergyGauge® I USRFZB v3.0 Page4 Manual J Summer Calculations Residential Load-Component Details (continued) Project Title: Climate:FL_FORT_LAUDERDALE TOLL BROTHERS PARKLAND SAVIERO 2969 2012 PARKLAND, FL !wHOLE HOUSE TOTALS ,. ·iii: .. " a -I. ' Sensible Envelope Load All Zones Sensible Duct Load Total Sensible Zone Loads Sensible ventilation Blower Whole House Total sensible gain Totals for Cooling Latent infiltration gain (for 64 gr. humidity difference) Latent ventilation gain Latent duct gain Latent occupant gain (34.0 people @ 200 Btuh per person) Latent other gain Latent total gain TOTAL GAIN -~.: ...... .. . ' -~·,,;·:.;~·-:~.:::<. _,, c ~ >·, 1. Central Unit # 2. Central Unit # *Key: Window types (Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U -Window U-Factor) (lnSh-Interior shading device: none( No), Blinds( B), Draperies( D) or Roller Shades(R)) -For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS-Insect screen: none(N), Full( F) or Half(Y.)) (Ornt -compass orientation) EnergyGauge® I USRFZB v3.0 11/28/2012 39832 Btuh 8058 Btuh 47891 Btuh 0 Btuh 0 Btuh 47891 Btuh 6366 Btuh 0 Btuh 2084 Btuh 6800 Btuh 0 Btuh 15249 Btuh 63140 Btuh 41500 Btuh 23400 Btuh Version 8 Page 5