HomeMy WebLinkAbout2013040381-ApplicationCITY OF PARKLAND 6600 UNIVERSITY DRIVE PARKLAND, FLORIDA 33067 BUILDING DEPARTMENT PERMIT A/C CHANGE OUT Confirm. #: 553 MASTER #: 2013040381 PERMIT #: 2013040381 PERMIT TYPE: AC JOB DESCRIPTION: A/ C CHANGE-OUT ISSUED DATE: 04/26/2013 BY: ADM02 JOB ADDRESS: 7035 LONG LEAF DR JOB VALUE: $ 10,554.00 BLOCK: K ADDR NBR: OWNER NAME: LOT: 58 SUBDIVISION #: 10102 LUGIOYO, RAFAEL & LACE CHERYL 1076-PGCC*K APPLICANT: BLOCK, SAMUEL DBA: CUSTOM AIR DESIGNS TYPE: CONTRACT JOB PHONE: ( 9 54 ) 7 8 5-912 8 CERT NBR: 5883 Permit holder acknowledges through acceptance of this permit that seperate permits must be obtained as required by Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further he/she acknowledges responsibility to comply with all requirements of the Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this jurisdiction, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10) ,F.S. W~ING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND. TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s:713.135,F.S. F.B.C. 304.3 Permit expires within six(6) months of issue date or three(3) months of last inspection date. Building Official or Authorized Signature Date For Inspection, Call (954) 757-4107 CDPR2020 C~PR1120 -Permit Payment Slip CITY OF PARKLAND Permit Payment Slip PAYMENT SLIP NBR: PT-2013040381 PERMIT NBR 2013040381 JOB DESCRIPTION A/C CHANGE-OUT JOB ADDRESS TYPE AC 7035 LONG LEAF DR STATUS READY JOB PHONE (954)785-9128 LOT 'Slr" BLOCK -K-- SUBDIVISION PGCC*K APPLICANT CN BLOCK, SAMUEL DBA CERT NBR 5883 CUSTOM AIR DESIGNS OWNER INFORMATION LUGIOYO, RAFAEL & LACE CHERYL 7035 LONG LEAF DRIVE PARKLAND FL 33076- FEE CODE DESCRIPTION BRWD BROWARD COUNTY DBPR BCAIB & CILB SURCHARGE DCAF DEPT OF COMMUNITY AFFAIRS NOC NOTICE OF COMMENCEMENT FL PERMM2 RES CONST COST OVER $1,000 ME USER ADM13 ADM13 ADM13 ADM13 ADM13 THIS IS NOT A RECEIPT \ MASTER NBR 2013040381 TOTAL DUE AMOUNT DUE 7.48 3.72 3.72 5.00 248.31 $268.23 City of Parkland CO-Plus for Windows 95/98/NT Printed on: 4/18/2013 9:59:48AM Page 1 of 1 Printed By: ADM13 City of Parkland Building Permit Application www.cityofparkland.org Contact Person: Phone#: E-mail: ALL OF THE FOLLOWING MUST BE FILLED IN BY APPLICANT, ACCORDING TO F.S. 713.135 Company Name Master Permit Number Business Address 1).. 5w 6 51". Date State ZiP Phone# Construction Value Property Owner's Name c Engineer's license # Owner's Street Address 7 0 Phone# City State Architect's Name "I Architect's license # Block K Phone# -3 j()tv Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of permit and that all work will be performed to meet the standards of all laws regulating construction in the City of Parkland, Florida. I understand that a separate permit may be secured for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, BOILERS, TANKS, AIR CONDITIONERS, ROOFING, SHUTIERS, ETC. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATIORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Contractor Notification E-mail: Print Name of Qualifier/Builder: 5 m ~&.... {)_ c/ 0 his before me, the undersigned otary Public of the Slfie of Florida, personally appeared Sti-l!'li>t.t / /T. V/6c /C and whose name is subscribed to and within the instrument, and he/she ackn wle~e/she executed it. & /1 ~roperty Owner Notification E-mail: /" b.J jl {;/)I"J'' -, D Produced identification I I I ----1 I NOT I I I _____ I Application Approved By: _______ ~--::;r"--'\-------------- Permit Officer ~ " . Date: ___ L(-+---+/_.f _ _....,""""l-')"'----- CFN # 111469858, OR BK 49705 PG 1330, Page 1 of 1, Recorded 04/17/2013 at 10:58 AM, Broward County Commission, Deputy Clerk 3270 Permit# Folio# 't7Lt/ 31 NOTICE OF COMMENCEMENT The undersigned hereby gives notice thet lmprov..,..nt will be made to certain real propelly and In -nee with C .... r 713, Flolklll Statutes, the following lnformetlon Is provkleclln this Notice of Commencement : 1. Lepl Dn<orlptlon of Propeny: 3. e. Owner """"' and address: b. lntereat In property: c. Name and addreas of 1M simple titleholder (II other than Owner): 4. a. Contractor """"' and addreas: b. Ccntractor'a phona number: 5. a. Surety name and addreaa: b. Sunoty'a phona number: c. Amount of bond: $ ____________________________________________ __ &. a. Lender """"' and add,...: b. Lender's phona number: 7. a. Persona within the State of Florida-.-by OwMr upon whom notices or other documente may be .. rved aa provldad by Sactlon 713.13(1Ke)7., Florida Statutn: Nama: b. Phona number: 8. L In addition to hlmull or harsalf, the OwMr -~~~n- 9. Expiration date of notice of commencsmant : (the expl.-dote II 1 yew from the date olm:onling unless a diflorem dotola opodlled) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I. SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT \MTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. =~~a)o~-OftbrlDirecto~--nage __ r ____________ _ fdll1Nama ~ f!lolNama TlllaiOfllca TltleiOIIIcs STATE OF FLORIDA COUNTY OF BROWARD The lo"!<flng lnsiiJimut wr acknowledged before mathis J1_ day of ..~.A~nf-"nl-l· ... i-------..(/013 By LDMfLl:L .. _f.2.c£ I o~.or o-=-----------lor _______________ _ ~-or oproducedthe-.gtypaof-: Signature of Notary Publlc:_£~?-==:o;;~c;F5=~'7.""".-= .... .------ PrlntName: __ ~t:;;;;-~~-;:::~~:::::~;;:;--(SEAL) VEBfF!AADON PUBS!JN!T TO SECTION 92.521. FLORIDA STATUJES Under pane-of perjury, I declare thet I have read the foregoing and thet the-elated In lara true, to the-of my "-**geand """"'· , IIGIIry I'UIIIIe • llltt of Florida G) DOMio\ VECCHIONE ' .., c-. Earplrea Apr 21, 2014 ~ .._.... t1 DD 115252 Slgnetu~ol of Ownarjo) or ~I)' Authorized Olftcer/llllactortPa~nager who olgnad above: By~ ~<#1-7ri-tt-By ___________ _ City of Parkland Building Division 6600 University Drive Parkland, FL 33067 Phone 954-753-5447 Fax 954-753-8838 A/C & Mechanical Replacement Information This form and ARI Listing must accompany each permit application for the replacement of Air Conditioning or Mechanical Equipment. Please supply a separate data sheet for each Unit being replaced. Contractor C"15TOih /t;d, o~rtpiV[ . PermitNumber ______ _ Job Address 70 ) f Lv,'-'f L c a F OILtvf' Lot t:.J'? Block_L Subdivision fPr-ttt::L.~tvp hL£ + CoiA,.,,-n; C/,. £ OLD UNIT DATA NEW UNIT C4tt.t!-l 6f\ Manufacturer f}m t/t, t/.J;v rf .~~,..clq~-r' J.-'-1 o M ~ 't n1 C.U. Model# '-! f) 7/} '> () 't«! E I f.Jc:~ f5 Fv '-t (J 1v du{){J-A.H.U. Model# Tt?P17~0C 4 :J.J/11 S fi> Package Unit Model # z EERISEER /{ )elf" A.. ARI Reference Number 4 }fj)-Jf6 /0 KWHeat /() 4 Nominal Tons t, (CJ Max Fuse I Breaker /0 YES NO Thermostat YES V NO YES NO Smoke Detector YES NOV YES NO Heat Recovery YES NOV YES NO Modify Ducts YES NOv YES NO Stand I Curb I Slab YES NO~ ********************** Change Disconnect YES NO .f':: ********************** Need Ladder For Inspection YES NO V Package Unit I I Miscellaneous mectric Packag_e Unit I I Contractor Signature £/J"~J' ~ ~ State License I R~tration _ _c=C_f}__.£_· _c_-_f.i--<-J---']~f--'-6_'.2. ______ Date 't-1? ... I 1 Broward County Certificate of Competency ________________ _ Application Approved by: -------;-Lr---"5--.;. .... -~~-._· _· _· _J ______ V..:.._f _/,----'--t+-[--_._1=":1'---- Rev. 1/09 k:;.~ustom ~designs Project Summary Entire House Custom Air Designs Job: Date: May 23, 2012 By: Roger K. Campbell 1246 SW 6th Street, Pompano Beach, FL 33069 Phone: 954-785·9128 Fax: 954·785-9698 Email: roger@customairdesigns.com Web: www.customairdesigns.com Pro· ect Information For: Cheryl Lace 7035 Long Leaf Drive, Parkland, FL 33076 Phone: 954-646-7974 Notes: Desi n Information Weather: Fort Lauderdale Hollywood, FL, US Winter Design Conditions Outside db 51 oF Inside db 70 oF Design TD 19 oF Heating Summary Structure 19908 Btuh Ducts 8983 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 28891 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) : Volume (ft3) Air changes/hour Equiv. AVF (cfm) Heating 2311 18488 0.32 99 Simplified · Average 0 Cooling 2311 18488 0.16 49 Heating Equipment Summary Make Trade Model AHRI ref n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 28891 Btuh 28891 Btuh 13 OF 2086 cfm 0.072 cfm/Btuh 0 in H20 Summer Design Conditions Outside db 91 oF Inside db 72 oF Design TD 19 oF Daily range L Relative flumidity 50 % Moisture difference 69 gr/lb Sensible Cooling Equipment Load Sizing Structure Ducts Central vent (0 cfm) Blower Use manufacturer's data Rate/swing multiplier Equipment sensible load 30627 Btuh 9299 Btuh 0 Btuh 0 Btuh n 0.96 38289 Btuh Latent Cooling Equipment Load Sizing Structure Ducts Central vent (0 cfm) Equipment latent load Equipment total load Req. total capacity at 0.70 SHR 3112 Btuh 4047 Btuh 0 Btuh 7159 Btuh 45448 Btuh 4.6 ton Cooling Equipment Summary Make Trade Cond Coil American Standard 4A7A5049E10008 TAM7AOC42H31SB 4385756 AHRI ref Efficiency Sensible cooling Latent cooling 13.0 EER, 16 SEER Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 32200 13800 46000 2086 0.052 0 0.85 Btuh Btuh Btuh cfm cfm/Btuh in H20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed . .-.... -+-Wrightsoft'' Right-Suite® Universal2012 12.0.09 RSU10135 ACCII. C:\Documents and Settingsllace 4 ton.rup Calc= MJ8 Front Door faces: N 2013-Apr-18 07:53:50 Page 1 ya\0~ -);a\{)'1\l'e(ISiOI\) )-..--. ~\.Otl'ef <~otltotl ~-I i_ t /' f"-~ ~-.:"" ' //--~-,-.....,' \ . '""' '·,,_-,r + • <) -Y-tJ-1 ~ o.,. 0?. ·-s. ~a_t9,. ~-' -;-/Shaded "FRONTAL AREA" / 2 HEIGHT x WIDTH Unit size limits: • Hei&ht/Width !: 13 • Height/Depth :s 1.2 ... for units lleyond these limits, use larger "Frontal Area" · Existing concrete slab on grade (min 3000 psi, min 4" thid:) Ref DESIGN SCHEDULE for number of dips along UNIT WIDTH (each side ) Central A/C System Condensing Unit 1 1 Tie-Down Clip Diagram Scale: ~i • = 1 '•0" Isometric DESIGN SCHEDULE: UOmph 130mph Exp 'C' + 'D' Exp 'C'+ 'D' 24.7 psf 29.0 psf Frontal #lOSMS #lOSMS Area perOip: per Clip: Up To: (1} (2} Ill 121 8ft> 2 I 2 2 1 2 lOft> 2 2 2 2 12Ft' 2 2 2 2 16Ft' 2 2 2 2 20ft' 3 2 3 2 25 It' 3 2 4 2 30ft' 4 2 4 I 3 35 ft2 4 3 5 I 3 40 It' s 3 5 4 --'-· __ c ___ Schedule gives minimum nAmber of tie-down dips required alons each side of conden!ing unit· see diagram. I CENTRAL A/C SYSTEM CONDENSING UNITS 140mph lSOmph 156mph 160mph l65mph 170mph Exp 'C + '0' Exp 'C' + 'D' Exp'C + '0' Exp'C+'D' Exp 'C' + '0' Exp'C + 'D' 33.6psf 38.6 psf 41.7 psf 43.9 psf 46.7psf 49.6 psf ltlOSMS lllOSMS #lOSMS #lOSMS lllOSMS lllDSMS perOip: per Cftp: per CUp: per Clip: per Clip: perOip: (1) i (2} Ill I 121 Ill I 12) Ill !121 Ill 12) Ill (2) 2 2 2 2 2 2 2 2 2 2 2 "2 2 2 2 2 2 2 2 2 2 2 3 2 ---2 2 2 2 3 2 3 2 3 2 3 2 ---3 2 3 2 3 2 3 2 4 2 4 I 3 -·--3 2 4 3 4 3 4 3 4 3 5 3 r--4 3 5 3 5 3 5 3 5 4 6 4 --. -5 3 5 4 6 4 6 4 6 4 7 4 --5 4 6 4 7 I 4 7 5 7 5 8 5 --6 4 7 5 8 I 5 8 s 8 s 9 6 ---· ·------'--· L_ .. ~---··---~'-----'------3 ~-· ;-~· -l ij• ....... .. : I ~ .--J .. >\, "'" i;".-./ ... · :i B .. <":. i• ~-· ~ Pre punched slots for screws to condensing unit housing Ill or (2) holes at bottom flange ..:--· .,..,_ .( . ' -"'• ""--. . ··<'$~~-Steel: 14ga min Alum: 0.080" min 2 1 Tie-Down Clip Sule: 3" sl'-0" ·~ ·~ .· Isometric #10 SMS to unit housing (22ga min). Qua!ltity per DESIGN SCHEDULE · (1) l'." ITW Tapcon per dip, with: • lY•" min embed • 2~2" min edge dist Clip Fastener Detail Scale: 1 ¥," : 1 '-0" Isometric DESIGN NOTES: wind loads perASce 1-10 for solid freestanding structures at grade: ASD Loads coeff = 0.6 Wind Speed & Exposure as noted in design schedules. Condensing unit height 15 ft max above grade Kzt:1.0, Kd•0.85, G:0.85 Cf=l.SS (H/W ratio!: 1.3} GENERAL NOTES: ·--r.-Desig!l is in accordance with the requirements of the 2010 Florida Building Code for use within & outside the Hi&h Velocity Hurrlune Zone (HVHZ). 2. This eneineerlng certifies oniV the structural lntearity of those systems, components, and/or other construction e>tpllcitly specified herein. 3. The existing host structure must be capable of supporting the loaded system as verified by building department or architect I engineer of record. No warranty, either expressed or implied, is contained herein. 4. Systems shall be a$ noted herein. All references to components, extrusions, & other installation criteria shan conform to that of applicable product approval &/or mfr's specs. 5. Where site conditions deviate from those shown in this plan, revisions may be required or a separate site-specific engineering evaluation p&rformed. 6. Engineer seal affixed hereto validates struCtural design as shown only. Use of this specification by contractor, et. al. indemnifies &. saves harmless this engineer for all costs & damages including legal fees & appellate fees resulting from deviations from this plan 7. Any modifications or additions to this document will invalidate engineer's certification. 8. Except as expressly provided herein, no additional certifications or affirmations are intended. ~' 0-~ '~ ~ ~ ~ L.tJ • t.a 2: ~ u - E c :::J .... w c ~~ -~ ~CJ;;: wz= uo~ ~ 0 2Ed Cl) I A.z ~::) UCJ z ZH-:~cnQ) g~~ Q l'tJ I ~ 0.1) w c::t ......... 1-U, OJ\!Ht~r,,_."" ilOII"''"'-'¥rol-,r.<)O lau~f--~ Drawing No. ElOTDl -. . • AIIDI ,... •••il CERTIFIED™ www.ahrid1 rectory.org This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. Certificate of Product Ratings AHRI Certified Reference Number: 4385756 Date: 4/18/2013 Product: Split System: Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 4A7A5049E1 Indoor Unit Model Number: *AM7AOC42H31 Manufacturer: AMERICAN STANDARD, INC. Trade/Brand name: ALLEGIANCE 15 Manufacturer responsible for the rating of this system combination is AMERICAN STANDARD, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): EER Rating (Cooling): SEER Rating (Cooling): 46000 13.00 16.00 • Ratings followed by an asterisk(") indicate a voluntary rerate of previously published data. unless accompanied with a WAS. which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2013 Air-Conditioning, Heating, and Refrigeration Institute /! UD! Air-Conditioning, Heating, ... •• •• and Refrigeration Institute CERTIFICATE NO.: 130107613945448348 City of Parkland Building Division 6600 University Drive Parkland, FL 33067 Phone 954-753-5447 Fax 954-753-8838 AIC & Mechanical Replacement Information This form and ARI Listing must accompany each permit application for the replacement of Air Conditioning or Mechanical Equipment. Please supply a separate data sheet for each Unit being replaced. Contractor ci.lt) Jc;n /},;.._ P-es 'J~' Permit Number ______ _ JobAddress ltJ?lf Lo•v& Le'7-J 1}/.;,v·l Lot _5_L_ Block X_ Subdivision P ff I! ILL q,.., J Ce, /[ 'T G .. t"-' kJ {/,..6 OLD UNIT DATA NEW UNIT Manufacturer C.U. Model# A.H.U. Model# Package Unit Model # 7 EERISEER ){ ) G"ftt ARI Reference Number '-J 3 ¥)]v/7 JO KW Heat J(} Nominal Tons 3 Max Fuse I Breaker Co YES NO Thermostat YES NO YES NO Smoke Detector YES NO YES NO Heat Recovery YES NO YES NO Modify Ducts YES NO YES NO Stand I Curb I Slab YES NO ********************** Change Disconnect YES NO ********************** Need Ladder For Inspection YES NO Package Unit I I Miscellaneous Electric Package Unit I I Contractor Signature d;·---n-1-u?tf//~/"C / State License I Registration ___.(""-.---'-~-{"-.--.::.t!~>~~'?"'-5-=-.S--'--T._.L _______ Date '-1 -/ t' /5 Broward County Certificate of Competency----------------- Rev. 1/09 k:;;~ustom ~designs Project Summary Entire House Custom Air Designs Job: Date: Apr 18, 2013 By: 1246 SW 6th Street, Pompano Beach, FL 33069 Phone: 954-785-9128 Fax: 954-785-9698 Email: roger@customairdesigns.com Web: www.customairdesigns.com Pro·ect Information For: Cheryl Lace 7035 Long Leaf Drive, Parkland, FL 33076 Phone: 954-646-797 4 Notes: Desi n Information Weather: Fort Lauderdale Hollywood, FL, US Winter Design Conditions Outside db 51 oF Inside db 70 oF Design TO 19 oF Heating Summary Structure Ducts Central vent (0 cfm) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 14393 Btuh 4850 Btuh 0 Btuh 0 Btuh 0 Btuh 19243 Btuh Simplified Average 0 Heating Cooling 1320 10560 0.23 40 Area (fF) 1320 Volume (ft3 ) 10560 Air changes/hour 0.45 Equiv. AVF (cfm) 79 Heating Equipment Summary Make Trade Model AHRI ref n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 19243 Btuh 19243 Btuh 12 OF 1496 cfm 0. 078 cfm/Btuh 0 in H20 Summer Design Conditions Outside db 91 oF Inside db 72 oF Design TO 19 oF Daily range L Relative flumidity 50 % Moisture difference 69 gr/lb Sensible Cooling Equipment Load Sizing Structure Ducts Central vent (0 cfm) Blower Use manufacturer's data Rate/swing multiplier Equipment sensible load 23336 Btuh 7701 Btuh 0 Btuh 0 Btuh n 0.96 29764 Btuh Latent Cooling Equipment Load Sizing Structure Ducts Central vent (0 cfm) Equipment latent load Equipment total load Req. total capacity at 0.70 SHR 2699 Btuh 2398 Btuh 0 Btuh 5096 Btuh 34861 Btuh 3.5 ton Cooling Equipment Summary Make Trade Cond Coil American Standard 4A7A5036E1000A TAM7AOC36H31SB 4385749 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling 13.0 EER, 16 SEER 24920 10680 35600 Actual air flow Air flow factor Static pressure Load sensible heat ratio 1496 0.048 0 0.86 Btuh Btuh Btuh cfm cfm/Btuh in H20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ~ -fir Wrightsoft• Right-Suite® Universal2012 12.0.09 RSU10135 AC~ C:\Documents and Settings\Lace 3 ton.rup Calc= MJ8 Front Door faces: N 2013-Apr-18 07:58:55 Page 1 + \11110~ . ' . tal 1)\~e(ISiOl\ I . \\.Oll~ec 1-\0rltot' i-///~:, . -' r-~,:~'· \ ~-I . 4 +~~o~+ ca-a.~ l9.,.. ~· " .,.. /Shaded "FRONTAL AREA" / = HEIGHT x WIDTH Unit size limits: • Height/Width s 1.3 • Height/Depth s 1.2 ... for units beyond these Umlts, use. larger "Frontal Area" ./."\· :. " ~>"" · Existing concrete slab on srade (min 3000 psi, min 4" thick) '" ''""" '· 1 ' .. -~· .• Ref D£SIGN SCH£ DULE for numbe.r of clips along UNIT WIDTH (each side ) Central A/C System Condensing Unit 1 1 Tie-Down Clip Diagram Scale:~~· = t••fl' Isometric DESIGN SCHEDULE: Schedule aives minimum nAmbe.r of tie-down dips required alone each side of condening unit-see diagram. CENTRAl A/C SYmM CONDENSING UNITS 120mph 130mph 140mph ISO mph 156mph 160mph 165mph 170mph EJ<p 'C'. 'D' Exp 'C' + 'D' Exp 'C + '0' EJ<p 'C'. 'D' EJ<p 'C + 'D' Exp'C+'D' Exp 'C + '0' Exp'C'+ 'D' 24.7 psf 29.0 psf 33.6psf 38.6psf 41.7 psf 43.9 psf 46.7 psf 49.6 psf Frontal #lOSMS #lOSMS #lOSMS lllOSMS ltlOSMS #lOSMS UOSMS #lOSMS Area perOip: per Clip: perOip: per CHp: per Clip: per Clip: per Clip: per Clip: Up To: Ill 121 11) (2) (1) i (2) 111 I 121 111 I 121 111 I 121 (1) ' (2) (1) (2) 8ft' 2 ! 2 2 2 2 2 2 ' 2 2 2 2 2 2 2 2 '2 lOft' 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 I ---12ft' 2 2 2 2 2 2 2 2 3 2 3 2 3 2 3 2 J --16ft' 2 2 2 2 3 2 3 2 3 2 3 2 4 2 4 I 3 --~ 20ft' 3 2 3 2 3 2 4 3 4 3 4 3 4 3 5 3 J f-25ft' 3 2 4 2 4 3 5 3 5 3 5 3 5 4 6 4 --. -30ft' 4 2 4 I 3 5 3 5 4 6 4 6 4 6 4 7 4 I -J 35ft' 4 3 5 I 3 5 4 6 4 7 I 4 7 s 7 5 8 5 -· 40ft' 5 3 5 4 6 4 7 5 8 I 5 8 5 8 5 9 6 I ---· -'·--~-··--··-'-----'-----·--L.-------'-------3 i-1.".) ~-· <f• ' .: I j ~ >a ~00 .. ,. ~ s <<:::~ :i':.r •.. :! Prepunched slots for screws to condensins unit housing (1) or(2) holes at bottom flange ..:-· ·."" (· .. ' ~~ "'--. -~ .. · Steel: 14p min Alum: 0.080" min --2 1 Tie-Down Clip Scale: 3" s 1'-0" . '. ·,· Isometric " 1110 SMS to unit housing (22sa min). Quantity per DESIGN SCHEDULE · (1) ~" ITW Tapcon per dip, with: •l~•· min embed • 2~2" min edse dist Clip Fastener Detail Scale: 1¥," = 1'-o" Isometric DESIGN NOTES: wind loads perAsCE 1-10 for solid freestanding structures at grade: ASD Loads coeff = 0.6 Wind Speed & EJ<posure as noted in design sdledules. Condensing unit height: 15 ft max above grade Kzt=l.O, Kd=0.85, G=0.85 Cf=l.55 (H/W ratios 1.3) GENERAL NOTES: 'T.Deslgn is in accordance with the requirements of the 2010 Florida Building Code fDf' use within & outside the Hish Velocity Hurr!Qne Zone (HVHZ). 2. This encineerlns certifies only the structural Integrity of those systems, components, and/or other construction eiCJIIidtly specified herein. 3. The existlna host struaure must be capable of supportina the loaded system as verified by buildin& department or architect I enaineer of record. No warranty, either expressed or implied, is contained herein. 4. Systems shall be as noted herein. All references to components, extrusions, & other installation criteria shan conform to that of applicable product approval &/or mfr's specs. s. Where site conditions deviate from those shown in this plan, revisions may be required or a separate site-specific ensineering evaluation performed. 6. Enslneer seal affixed hereto validates structural desitn as shown only. Use of this specification by contractor, et. al. indemnifies & saves harmless this engineer for all costs & damages including legal fees & appellate fees resulting from deviations from this plan. 7. Any modifications or additions to this dowment will invalidate engineer's certification. 8. Except as expressly provided herein, no additional certifications or affirmations are intended. V\ ~} ~-~ V\ >. '""~~ y L4J • % ~ u - E cc :I _, lU c ~~·~ !Z~<e lU z = uo~ 2~~ <I) I D.z ~:;) u~ zt-t-J <I) Q) 0~~ 00 ro I Z biJ ILIOV t::u-; 0~1,,,..., .... ., IMf•,,..._.,..,..,_, r:<JO lo<..I....__ •• _IJ,I.J.l Drawing No. ElOTDl IJ ~LIDI ......... CERTIFIEDTM This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. www.ahridt rectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4385749 Date: 4/18/2013 Product: Split System: Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 4A7 A5036E1 Indoor Unit Model Number: *AM7AOC36H31 Manufacturer: AMERICAN STANDARD, INC. Trade/Brand name: ALLEGIANCE 15 Manufacturer responsible for the rating of this system combination is AMERICAN STANDARD, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): EER Rating (Cooling): SEER Rating (Cooling): 35600 13.00 16.00 • Ratings followed by an asterisk(") indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this CertifiCate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2013 Air-Conditioning, Heating, and Refrigeration Institute ~ UDiifl Air-Conditioning, Heating, ... •• • and Refrigeration Institute CERTIFICATE NO.: 130107613297911052